Installation GREYHOUND Switch
Release
05
02/2018
Technical support
https://hirschmann-support.belden.eu.com
User Manual
Installation
GREYHOUND Switch - GRS1042/GRS1142
GREYHOUND Power Supply Unit - GPS1/GPS2/GPS3
GREYHOUND Media Module - GMM20/30/32/40/42
The naming of copyrighted trademarks in this manual, even when not specially indicated, should
not be taken to mean that these names may be considered as free in the sense of the trademark
and tradename protection law and hence that they may be freely used by anyone.
© 2018 Hirschmann Automation and Control GmbH
Manuals and software are protected by copyright. All rights reserved. The copying, reproduction,
translation, conversion into any electronic medium or machine scannable form is not permitted,
either in whole or in part. An exception is the preparation of a backup copy of the software for
your own use.
The performance features described here are binding only if they have been expressly agreed
when the contract was made. This document was produced by Hirschmann Automation and
Control GmbH according to the best of the company's knowledge. Hirschmann reserves the right
to change the contents of this document without prior notice. Hirschmann can give no guarantee
in respect of the correctness or accuracy of the information in this document.
Hirschmann can accept no responsibility for damages, resulting from the use of the network
components or the associated operating software. In addition, we refer to the conditions of use
specified in the license contract.
You can get the latest version of this manual on the Internet at the Hirschmann product site
(www.hirschmann.com).
Hirschmann Automation and Control GmbH
Stuttgarter Str. 45-51
72654 Neckartenzlingen
Germany
GREYHOUND Switch
Installation GREYHOUND Switch
Release
05
02/2018
3
Contents
Safety instructions 6
About this Manual 16
Legend 17
1 Description 18
1.1 General device description 18
1.2 Device name and product code 20
1.2.1 Basic device 20
1.2.2 Power supply units 21
1.2.3 Media modules 22
1.3 Device views 24
1.3.1 GRS1042 24
1.3.2 GRS1142 25
1.3.3 Power supply units 26
1.3.4 Media modules 27
1.4 Power supply 29
1.5 Signal contact 30
1.6 Ethernet ports 30
1.6.1 1/2.5 Gbit/s F/O port 30
1.6.2 100/1000 Mbit/s F/O port 30
1.6.3 100 Mbit/s F/O port 31
1.6.4 10/100/1000 Mbit/s twisted pair port 31
1.6.5 Support of PoE(+) 32
1.6.6 Out-of-band management port 32
1.7 Pin assignments 33
1.8 Display elements 33
1.8.1 Device state 33
1.8.2 Port status 35
1.8.3 Media module status 37
1.9 Management interfaces 39
1.9.1 V.24 interface (external management) 39
1.9.2 USB interface 40
1.9.3 SD card interface 41
2 Installation 42
2.1 Checking the package contents 42
2.2 Installing the SD card (optional) 42
4
Installation GREYHOUND Switch
Release
05
02/2018
2.3 Mounting the cover panel and the power supply unit
(optional) 43
2.3.1 Mounting the cover panel 43
2.3.2 Mounting the power supply unit 43
2.4 Mounting a media module (optional) 44
2.5 Installing and grounding the device 45
2.6 Connecting the terminal blocks 47
2.6.1 Supply voltage 47
2.6.2 Signal contact 51
2.7 Installing an SFP transceiver (optional) 51
2.8 Operating the device 52
2.9 Connecting data cables 52
2.10 Filling out the inscription label 52
3 Making basic settings 53
4 Monitoring the ambient air temperature 54
5 Maintenance and service 55
6Disassembly 56
6.1 Removing a power supply unit 56
6.2 Removing a media module 57
6.3 Removing an SFP transceiver 57
6.4 Removing the device 58
7 Technical data 59
7.1 General technical data 59
7.2 Dimension drawings 63
7.3 EMC and immunity 66
Installation GREYHOUND Switch
Release
05
02/2018
5
7.4 Network range 69
7.5 Power consumption/power output 72
8 Scope of delivery, order numbers and
accessories 73
9 Underlying technical standards 76
A Further support 78
6
Installation GREYHOUND Switch
Release
05
02/2018
Safety instructions
General safety instructions
You operate this device with electricity. Improper usage of the device
entails the risk of physical injury or significant property damage. The
proper and safe operation of this device depends on proper handling
during transportation, proper storage and installation, and careful
operation and maintenance procedures.
Before connecting any cable, read this document, and the safety
instructions and warnings.
Operate the device with undamaged components exclusively.
The device is free of any service components. In case of a damaged
or malfunctioning the device, turn off the supply voltage and return the
device to Hirschmann for inspection.
Qualification requirements for personnel
Only allow qualified personnel to work on the device.
Qualified personnel have the following characteristics:
Qualified personnel are properly trained. Training as well as practical
knowledge and experience make up their qualifications. This is the
prerequisite for grounding and labeling circuits, devices, and systems
in accordance with current standards in safety technology.
Qualified personnel are aware of the dangers that exist in their work.
Qualified personnel are familiar with appropriate measures against
these hazards in order to reduce the risk for themselves and others.
Qualified personnel receive training on a regular basis.
WARNING
UNCONTROLLED MACHINE ACTIONS
To avoid uncontrolled machine actions caused by data loss, configure all
the data transmission devices individually.
Before you start any machine which is controlled via data transmission, be
sure to complete the configuration of all data transmission devices.
Failure to follow this instruction can result in death, serious injury, or
equipment damage.
Installation GREYHOUND Switch
Release
05
02/2018
7
Correct usage
Only use the device for those purposes specified in the catalog and in the
technical description. Only operate the device with external devices and
components that are recommended and permitted by the manufacturer.
The proper and safe operation of this product depends on proper handling
during transport, proper storage, assembly and installation, and
conscientious operation and maintenance procedures.
National and international safety regulations
Verify that the electrical installation meets local or nationally applicable
safety regulations.
Requirements for connecting electrical wires
Before connecting the electrical wires, always verify that the
requirements listed are complied with.
Requirements for connecting the signal contact
The following requirements apply without restrictions:
The electrical wires are voltage-free.
The cables used are permitted for the temperature range of the application case.
First connect the ground screw on the back of the device with the protective conductor
before you set up the other connections. When removing the connections, you remove the
protective conductor last.
Exclusively switch on the device when it is installed.
Relevant for North America:
Exclusively use 60/75 °C (140/167 °F) or 75 °C (167 °F) copper (Cu) wire.
Table 1: Requirements for connecting electrical wires
The following requirements apply without restrictions:
Limit the connected voltage with a current limitation or in accordance with its application.
Observe the electrical threshold values for the signal contact.
See “General technical data” on page 59.
Table 2: Requirements for connecting the signal contact
8
Installation GREYHOUND Switch
Release
05
02/2018
Requirements for connecting the supply voltage
Device variant Prerequisites:
All variants All of the following requirements are complied with:
The supply voltage corresponds to the voltage specified on the type plate
of the device.
The power supply conforms to overvoltage category I or II.
The power supply has an easily accessible disconnecting device (for
example a switch or a plug). This disconnecting device is clearly identified.
So in the case of an emergency, it is clear which disconnecting device
belongs to which power supply cable.
For supply voltage connections with protective conductor connection: First
connect the protective conductor before connecting the wires for the
supply voltage.
If your device comprises a 2nd supply voltage connection of this type: First
connect the protective conductor before connecting the wires for the
supply voltages.
Supply with DC voltage:
The wire diameter of the power supply cable is at least 1 mm² (North
America: AWG16) on the supply voltage input.
Supply with AC voltage:
The wire diameter of the power supply cable is at least 0.75 mm² (North
America: AWG18) on the supply voltage input.
The cross-section of the ground conductor is the same size as or bigger
than the cross-section of the power supply cables.
Use a power supply cable which is suitable for the voltage, the current and
the physical load.
Install an external fuse in the conductor that is not on ground potential.
Power supply
unit
characteristic
value C
All of the following requirements are complied with:
The power supply complies with the requirements for a safety extra-low
voltage (SELV) as per IEC/EN 60950-1.
Install a fuse suitable for DC voltage in the plus conductor of the power
supply.
Regarding the properties of this fuse:
See “Technical data” on page 59.
Table 3: Requirements for connecting the supply voltage
Installation GREYHOUND Switch
Release
05
02/2018
9
Power supply
unit
characteristic
value K
All of the following requirements are complied with:
Supply with DC voltage:
Install a fuse suitable for DC voltage in the plus conductor of the power
supply.
Connect the minus conductor to the ground potential. If the minus
conductor is not connected to the ground potential, also install an external
fuse in the minus conductor.
Regarding the properties of this fuse:
See “Technical data” on page 59.
Supply with AC voltage:
Install a fuse in the outer conductor of the power supply.
Connect the neutral conductor to the ground potential. If the neutral
conductor is not connected to the ground potential, also install an external
fuse in the neutral conductor.
Regarding the properties of this fuse:
See “Technical data” on page 59.
Power supply
unit
characteristic
value P
All of the following requirements are complied with:
The power supply complies with the requirements for a safety extra-low
voltage (SELV) as per IEC/EN 60950-1.
The power supply is potential-free. For power supply modules capable of
PoE, exclusively use a potential-free SELV power supply.
Install a fuse suitable for DC voltage in the plus conductor of the power
supply.
Regarding the properties of this fuse:
See “Technical data” on page 59.
Device variant Prerequisites:
Table 3: Requirements for connecting the supply voltage
10
Installation GREYHOUND Switch
Release
05
02/2018
Relevant for use in explosion hazard areas (Hazardous
Locations, Class I, Division 2)
Control Drawing for GRS 1042/1142 devices for use in Hazardous
Locations according to ANSI/ISA12.12.01-2015 Class I, Division 2,
Groups A, B, C, D
Rev.: 0 Document No.: 000205339DNR Page 1/2
Ordinary Location,
Non-Hazardous Area,
Non-Explosive Atmosphere
Explosive Atmosphere Class I
Division 2, Groups A, B, C, D
Hazardous Location
The use in Hazardous Locations is only allowed for GRS 1042/1142 model numbers
which are individually labelled:
“FOR USE IN CLASS I, DIVISION 2 HAZARDOUS LOCATIONS”
Nonincendive fi eld wiring circuits must be wired in accordance with the National Electrical
Code (NEC), NFPA 70 , article 501. CEC, Appendix J, Annex J 18.
The earth conductor must be at least the same wire size (mm² or AWG) as the supply con-
ductors.
WARNING – EXPLOSION HAZARD – SUBSTITUTION OF ANY COMPONENTS MAY
IMPAIR SUITABILITY FOR HAZARDOUS LOCATIONS OR EXPLOSIVE
ATMOSPHERES.
WARNING – EXPLOSION HAZARD – DO NOT DISCONNECT EQUIPMENT UNLESS
POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE
NON-HAZARDOUS.
Explosive Atmosphere Class I, Division 2, Groups A, B, C, D Hazardous Location
USB connection:
Equipment with non-incendive fi eld wiring parameters.
USB entity parameters:
V
OC
≤ 5.5 V I
SC
≤ 1.25 A C
a
≤ 10 μF L
a
≤ 10 μH
Relay contacts:
Equipment with non-incendive fi eld wiring parameters.
The relay terminals are dependent upon the following
entity parameters:
V
max
≤ 30 V I
max
≤ 90 mA C
i
≤ 2 nF L
i
≤ 1 μH
USB
Pin 1 and 4
SD
(Maintenance only)
Signal Contact
(Closed: OK;
Open: FAULT)
Ordinary location, no explosion hazard
Installation GREYHOUND Switch
Release
05
02/2018
11
Control Drawing for GRS 1042/1142 devices for use in Hazardous
Locations according to ANSI/ISA12.12.01-2015 Class I, Division 2,
Groups A, B, C, D
Rev.: 0 Document No.: 000205339DNR Page 2/2
Capacitance and inductance of the fi eld wiring from the non-incendive circuit to the asso-
ciated apparatus shall be calculated and must be included in the system calculations as
shown in Table 1.
Cable capacitance (C
cable
) plus non-incendive equipment capacitance (C
i
) must be less than
the marked capacitance (C
a
(or C
o
)) shown on any associated apparatus used.
The same applies for inductance (L
cable
, L
i
and L
a
or L
o
, respectively).
Where the cable capacitance and inductance per foot are not known, the following values
shall be used:
C
cable
= 60 pF/ft (196.85 pF/m)
L
cable
= 0.2 μH/ft (0.66 μH/m)
Table 1:
Non-incendive
Equipment
Associated
Apparatus
V
max
(or U
i
)≥V
oc
or V
t
(or U
o
)
I
max
(or I
i
)≥I
sc
or I
t
(or I
o
)
P
max
(or P
i
)≥P
o
C
i
+ C
cable
≤C
a
(or C
o
)
L
i
+ L
cable
≤L
a
(or L
o
)
Suitability for installation in particular applications is at the discretion of the Authority Having
Jurisdiction (AHJ).
12
Installation GREYHOUND Switch
Release
05
02/2018
Relevant for use in explosive atmospheres (European ATEX
Directive 2014/34/EU)
II 3G Ex nA IIC T4 Gc
Ta: 40 °F ... +158 °F (40 °C ... +70 °C) for temperature range
characteristic value T and E
Ta: +32 °F ... +140 °F (0 °C ... +60 °C) for temperature range
characteristic value S
DEKRA 17ATEX0024X
THE USB CONNECTOR MUST NOT BE USED WHEN THE DEVICE IS
OPERATED IN EXPLOSIVE HAZARDOUS LOCATIONS.
Special conditions for safe use
Install basic device and modules in a suitable enclosure providing a
degree of protection of at least IP54 according to EN 60529. Take into
account the ambient conditions under which the device will be used.
Make provisions to prevent transient disturbances from exceeding
more than 140 % of the connected rated voltage at the voltage inputs.
Shielded ground
The shielded ground wire of the twisted pairs cables is connected to the
front panel as a conductor.
Beware of possible short circuits when connecting a cable section with
conductive shield braiding.
ESD Guidelines
The modules are equipped with electrostatically sensitive components.
These can be destroyed, or their life cycles reduced, by the effects of an
electrical field or by a charge equalization if the connections are touched.
You will find information about electrostatically endangered assemblies in
DIN EN 61340-5-1 (2007-08) and DIN EN 61340-5-2 (2007-08).
List of
standards:
EN 60079-0:2012 + A11
EN 60079-15:2010
Installation GREYHOUND Switch
Release
05
02/2018
13
Device casing
Only technicians authorized by the manufacturer are permitted to open
the casing.
Keep the ventilation slits free to ensure good air circulation.
Make sure there is at least 3.94 in (10 cm) of space in front of the
ventilation slits of the casing.
Do not touch the housing during operation or shortly after switching off
the device. Hot surfaces can cause injury.
Mount the device horizontally in a cabinet or vertically on a flat surface.
Operating the device as a table unit is inadmissible.
See “Installing and grounding the device” on page 45.
Operating the device in the maximum surrounding air temperature and
stacking devices: When installing the device, make sure there is at
least one free rack space (approx. 5 cm) above the device, because
heat is discharged via the housing of the device.
If you are operating the device in a 19" switch cabinet: install sliding/
mounting rails for supporting the weight of the device.
Installation site requirements
Operate the device at the specified ambient temperature (temperature of
the ambient air at a distance of 2 inches (5 cm) from the device) and at
the specified relative humidity exclusively.
When you are selecting the installation location, make sure you
observe the climatic threshold values specified in the technical data.
Use the device in an environment with a maximum pollution degree
that complies with the specifications in the technical data.
14
Installation GREYHOUND Switch
Release
05
02/2018
CE marking
The labeled devices comply with the regulations contained in the following
European directive(s):
In accordance with the above-named EU directive(s), the EU conformity
declaration will be at the disposal of the relevant authorities at the
following address:
Hirschmann Automation and Control GmbH
Stuttgarter Str. 45-51
72654 Neckartenzlingen
Germany
www.hirschmann.com
The product can be used in the industrial sector.
Interference immunity: EN 61000-6-2
Emitted interference: EN 55032
Reliability: EN 60950-1
Warning! This is a class A device. This device can cause interference in
living areas, and in this case the operator may be required to take
appropriate measures.
Note: The assembly guidelines provided in these instructions must be
strictly adhered to in order to observe the EMC threshold values.
Device variant Directive
All variants 2011/65/EU (RoHS)
Directive of the European Parliament and of the Council on the
restriction of the use of certain hazardous substances in
electrical and electronic equipment.
All variants 2014/30/EU (EMC)
Directive of the European Parliament and of the Council on the
harmonisation of the laws of the Member States relating to
electromagnetic compatibility.
Only for device variants
featuring supply voltage with
characteristic value H:
2014/35/EU
Directive of the European Parliament and of the Council on the
harmonisation of the laws of the Member States relating to the
making available on the market of electrical equipment
designed for use within certain voltage limits.
Installation GREYHOUND Switch
Release
05
02/2018
15
LED or laser components
LED or LASER components according to IEC 60825-1 (2014):
CLASS 1 LASER PRODUCT
CLASS 1 LED PRODUCT
FCC note:
This device complies with part 15 of the FCC rules. Operation is subject
to the following two conditions: (1) this device may not cause harmful
interference; (2) this device must accept any interference received,
including interference that may cause undesired operation.
Appropriate testing has established that this device fulfills the
requirements of a class A digital device in line with part 15 of the FCC
regulations.
These requirements are designed to provide sufficient protection against
interference when the device is being used in a business environment.
The device creates and uses high frequencies and can also radiate these
frequencies. If it is not installed and used in accordance with this
operating manual, it can cause radio transmission interference. The use
of this device in a residential area can also cause interference, and in this
case the user is obliged to cover the costs of removing the interference.
Recycling note
After usage, this device must be disposed of properly as electronic waste,
in accordance with the current disposal regulations of your county, state,
and country.
16
Installation GREYHOUND Switch
Release
05
02/2018
About this Manual
The “Installation” user manual contains a device description, safety
instructions, a description of the display, and the other information that you
need to install the device.
Installation GREYHOUND Switch
Release
05
02/2018
17
Legend
The symbols used in this manual have the following meanings:
Listing
Work step
Subheading
18
Installation GREYHOUND Switch
Release
05
02/2018
1 Description
1.1 General device description
The GREYHOUND Switch devices are designed for the special requirements
of industrial automation. They meet the relevant industry standards, provide
very high operational reliability, even under extreme conditions, and also
long-term reliability and flexibility.
The devices allow you to set up switched industrial Ethernet networks that
conform to the IEEE 802.3 standard.
Basic device
You can choose from between a wide range of variants. You have the
option to set up your device individually based on different criteria:
Number of ports
Transmission speed
Types of connectors
Temperature range
Supply voltage range
Certifications
You have numerous options of combining the device characteristics. You
can determine the possible combinations using the Configurator which is
available in the Belden E-Catalog (www.e-catalog.beldensolutions.com)
on the web page of the device.
GRS1042
GRS1142
Installation GREYHOUND Switch
Release
05
02/2018
19
Power supply units
You have the option to select either 1 or 2 power supply units with different
input voltages:
Low Voltage / Power over Ethernet PoE(+)
High Voltage
You obtain the power supply units as accessories.
See “Order number” on page 73.
Media modules
You have the option to select either 1 or 2 media modules. By using a
media module, you obtain up to 8 additional Fast and/or Gigabit Ethernet
ports.
You obtain the media modules as accessories.
See “Order number” on page 73.
GREYHOUND Power Supply Unit
GREYHOUND Media Module
20
Installation GREYHOUND Switch
Release
05
02/2018
1.2 Device name and product code
The device name corresponds to the product code. The product code is
made up of characteristics with defined positions. The characteristic values
stand for specific product properties.
1.2.1 Basic device
Item Characteristic Characteris-
tic value
Description
1 ... 3 Product GRS GREYHOUND Switch
4 Series 1 GREYHOUND Series
5 Position of the
ports and power
supply inputs
0 Ethernet ports: front of device
Power supply inputs: back of device
1 Ethernet ports and power supply inputs: rear of device
6 Data rate 4 (10)/100/1000Mbit/s with 2.5 Gbit/s uplink ports
7 Hardware type 2 PoE(+) support
8 (hyphen)
9 ... 12 Configuration of
the ports
AT2Z 10 ×
RJ45 socket for 10/100/1000 Mbit/s Twisted
Pair connections
SFP slot for 1/2.5 Gbit/s F/O connections
6T6Z 6 ×
RJ45 socket for 10/100/1000 Mbit/s Twisted
Pair connections
4 × SFP slots for 1/2.5 Gbit/s F/O connections
and
2 × SFP slots for 100/1000 Mbit/s connections
13 Temperature
range
S Standard +32 °F ... +140 °F
(0 °C ... +60 °C)
C Standard with
Conformal Coating
+32 °F ... +140 °F
(0 °C ... +60 °C)
T Extended 40 °F ... +158 °F (40 °C ...
+70 °C)
E Extended with
Conformal Coating
40 °F ... +158 °F (40 °C ...
+70 °C)
14 Supply voltage 1 L Voltage input: low voltage
Rated voltage range
24 V DC ... 48 V DC
48 V DC ... 54 V DC
Can be combined with power supply unit with
characteristic value C or P
H Voltage input: high voltage
Rated voltage range
60 V DC ... 250 V DC
110 V AC ... 240 V AC, 50 Hz ... 60 Hz
Can be combined with power supply unit with
characteristic value K
15 Supply voltage 2 See position 14
16 Cover panel for
power supply
unit slot
0 not present
1 1 × cover panel for slot 2
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78