Danfoss HAME 86K (OEM) Operating instructions

Type
Operating instructions
7369105-0 HI.03.F1.5Q © HVAC 03/02 1
Instructions
HAME 86K
HVAC Series
Danfoss
Fig.2.9
Fig.3
Fig.2.5
Fig.2.6 Fig.2.7
Fig.2.8
Fig.2.1
Fig.2.2 Fig.2.3
Fig.2.4
Fig.1
Fig.1.2
Fig.2
Fig.4
Fig.5
2 HI.03.F1.5Q © HVAC 03/02 7369105-0
DANSK
1. Montering af HAME 86K på en
ventil (Fig. 1)
Fastgør motoren på ventilen med tre
skruer eller med omløber. (afhængig
af ventiltype.
2. Indstilling af funktionsomskifter
(Fig. 2, Fig. 2.1) Løs de to skruer i
låget og fjern låget. På printet er der
fire lus til rådighed til valg af
specialindstillinger.
Fig. 2.2 (Y = 2 – 10 V, fabriksindstilling)
Motorspindelen i HAME motoren
bevæger sig nedad i takt med at
styrespændingen stiger.
Fig. 2.3 (Y = 0 – 10 V)
Motorspindelen i HAME motoren
bevæger sig nedad i takt med at
styrespændingen stiger.
Fig. 2.4 (Y = 4 – 20 mA)
Motorspindelen i HAME motoren
bevæger sig nedad i takt med at
styrestrømmen stiger.
Fig. 2.5 (Y = 0 – 20 mA)
Motorspindelen i HAME motoren
bevæger sig nedad i takt med at
styrestrømmen stiger.
Fig. 2.6 (Y = 10 – 2 V)
Motorspindelen i HAME motoren
bevæger sig opad i takt med at
styrespændingen stiger.
Fig. 2.7 (Y = 10 – 0 V)
Motorspindelen i HAME motoren
bevæger sig opad i takt med at
styrespændingen stiger.
Fig. 2.8 (Y = 20 – 4 mA)
Motorspindelen i HAME motoren
bevæger sig opad i takt med at
styrestrømmen stiger.
Fig. 2.9 (Y = 20 – 0 mA)
Motorspindelen i HAME motoren
bevæger sig opad i takt med at
styrestrømmen stiger.
Bemærk:
Lusene kan indstilles før eller
efter selvjustering.
3. El-tilslutning (Fig. 3)
3.1 Styresignal
Styresignal fra regulatoren skal
tilsluttes klemme Y (indgangssignal)
og klemme SN (fælles) på HAME-
printet.
3.2 Udgangssignal
Udgangssignalet fra klemme X kan
anvendes til at indikere den aktuelle
position. Området afhænger af lusen
2/0 (2 – 10Veller 0 – 10V).
3.3 Forsyningsspænding
Forsyningsspændingen (24 V~
± 10%, 50 Hz) skal tilsluttes klemme
SN og SP.
4. Indikatoren viser slaglængden (Fig. 4)
5. Drift
Efter at der er sluttet strøm til
aktuatoren, starter denne en
selvjusteringsproces.
Lysdioden blinker, indtil
selvjusteringen er afsluttet. Varighed
normalt et par minutter, afhængig af
spindelvandringen. Ventilens
slaglængde gemmes i
hukommelsen efter afsluttet
selvjustering. Et tryk på RESET-
tasten (fig.2), vil genstarte
selvjusteringen. Hvis
forsyningsspændingen er afbrudt -
eller falder til under 80% - i mere
end 0.1sek. gemmes den aktuelle
ventilposition i hukommelsen. Alle
data vil således være sikret i
hukommelsen – også i tilfælde af
strømafbrydelse.
Bemærk: Efter hver demontering af
aktuatoren, skal
selvjusteringsproceduren gentages.
5.1 Fjernstyret selvjustering
Ved at klippe lus A, er det muligt at
fjernbetjene selvjusteringen.
Proceduren er følgende:
- afbryd lus A
- afbryd strømforsyningen
- tilslut strømforsyningen og afbryd
igen inden for 5 – 8 sekunder
gentag hele proceduren Næste
gang strømmen tilsluttes, vil
aktuatoren foretage en
selvjustering.
Bemærk: RESET- tasten er i funktion,
selv om lus A er afbrudt.
6. Overstyring af styresignal Y
(direkte drift) (fig.3)
Hvis klemme 2 er forbundet med
klemme SN i mere end 0,1 sekund,
vil motoren bevæge sig til øverste
position, uafhængig af
kontrolsignal Y. Hvis klemme 3 er
forbundet med klemme SN i mere
end 0,1 sekund, vil motoren bevæge
sig til nederste position, uafhængig
af kontrolsignal Y.
Bemærk: Udgangssignal X er ikke
direkte aktiv før motoren har
bevæget sig til dens ende – position.
Ende- positionerne har ingen
returforbindelse, som kan vise en
ukorrekt positionering. For at opnå
dette skal motoren bevæges til ende
– position ved direkte drift. I det
tilfælde justerer motoren dens
aktuelle position til dens relative
position.
Advarsel: Hvis klemme SN og SP
ombyttes i direkte drift,
ødelægges printet.
7. Funktionstest
Lysdioden indikerer om motoren er i
drift. Endvidere viser dioden
driftsstatus og eventuelle fejl.
Konstant lys
- normal drift
Ingen lys
- ikke i drift eller ingen
strømforsyning
Interval blink (1 Hz)
- selvjusteringstilstand
Interval blink (>3 Hz)
- strømforsyning for lav
- ventilslaglængde utilstrækkelig
(< 20 s)
- ende- position kan ikke nås
ENGLISH
1. Mounting the HAME 86K on a valve
(Fig. 1)
Fix the HAME 86K on the valve with
four screws or nut. (depends on
valve type)
2. Function switch setting
(Fig. 2, Fig. 2.1)
Unscrew two screws on the top of
the lid. Remove the lid. On the
printed board four jumpers are
available for selecting special
settings
Fig. 2.2 (Y = 2 – 10 V), factory
setting The HAME motor spindle
travels downwards on rising control
voltage.
Fig. 2.3 (Y = 0 – 10 V )
The HAME motor spindle travels
downwards on rising control voltage.
Fig. 2.4 (Y = 4 – 20 mA)
The HAME motor spindle travels
downwards on rising control current.
Fig. 2.5 (Y = 0 – 20 mA)
The HAME motor spindle travels
downwards on rising control current.
Fig. 2.6 (Y = 10 – 2 V)
The HAME motor spindle travels
upwards on rising control voltage.
Fig. 2.7 (Y = 10 – 0 V)
The HAME motor spindle travels
upwards on rising control voltage.
Fig. 2.8 (Y = 20 – 4 mA)
The HAME motor spindle travels
upwards on rising control current.
Fig. 2.9 (Y = 20 – 0 mA)
The HAME motor spindle travels
upwards on rising control current.
Note: Jumpers can be set before or after
self - adjustment.
3. Wiring (Fig. 3)
3.1 Control signal
Control signal from the controller
must be connected to terminals Y
(input signal) and SN (common) on
the HAME printed board.
3.2 Output signal
Output signal from the terminal X can
be used for indication of the current
position. Range depends on the
jumper 2/0 (2 – 10 V or 0 – 10 V).
3.3 Supply voltage
Supply voltage (24 V~ ± 10%,
50 Hz) must be connected to the
terminals SN and SP.
4. The indicator shows the stroke
length (Fig. 4)
5. Operation
After the actuator has been
connected with power supply, the
actuator will start the self-adjustment
procedure. The indicator LED flashes
until self-adjustment is finished. The
duration depends on the spindle
travel and would normally last a few
minutes. The stroke lenght of the
valve is stored in the memory after
self-adjustment has been completed.
To restart self-adjustment, press
7369105-0 HI.03.F1.5Q © HVAC 03/02 3
voltage is switched off or falls below
80% for more than 0.1 s, the current
valve position will be stored in the
memory and all data remain saved in
the memory also after the power
supply cut-out.
Note: After every dismounting the
actuator, self adjustment procedure
must be repeated!
5.1 Remote self- adjustment
Remote self-adjustment is possible
by clipping jumper A.
Follow the procedure:
- disconnect jumper A
- switch off the power supply
- switch on the power supply and
switch it off again within 5 to 8
seconds.
- repeat again the above procedure
At the next switch-on, the actuator
will perform the self-adjustment
procedure.
Note: The RESET key will remain in
function also after cutting out the
jumper A.
6. Override of the control signal Y
(direct operation) (Fig. 3)
If terminal 2 is connected with
terminal SN for more than 0.1 s, the
motor will move to its upper position
irrespective of signal Y.
If terminal 3 is connected with
terminal SN for more than 0.1 s, the
motor will move to its lower position
irrespective of signal Y.
Note: Signal X is not accurate in direct
operation mode, until motor moves to
its end - position.
Positioner has no return connection,
which can cause an incorrect
positioning. To avoid this, move the
motor to its end position in direct
operation mode. In this case motor
adjust its actual position to its relative
position.
Warning: Exchange of terminals SN
and SP in direct operation mode
destroys printed circuit.
7. Function test
The indicator light shows whether the
positioner is in operation or not.
Moreover, the indicator shows the
control status and faults.
Constant light
- normal operation
No light
- no operation or no power supply
Interval light (1 Hz)
- self adjusting-mode
Interval light (3 Hz):
• power supply too low
• insufficient valve stroke (< 20 s)
• end-position cannot be reached.
DEUTSCH
1. Montage des HAME 86K auf das
Ventil (Bild 1)
HAME 8K wird mit vier Schrauben
bzw. cupplungs mutter auf das Ventil
montiert (Hängt fom Ventil ab).
2. Funktionsschalter Einstellung
(Bild 2, Bild 2.1)
Schrauben Sie zwei Schrauben auf
den Deckel auf und entfernen Sie den
Deckel. Auf der Platine sind vier
Brücken zur Auswahl der besonderen
Einstellugen.
Bild 2.2 (Y = 2 – 10 V)
Werkseinstellung
Bei dem steigenden Spannung
verschiebt sich die Antriebsstange
nach unten.
Bild 2.3 (Y = 0 – 10 V)
Bei dem steigenden Spannung
verschiebt sich die Antriebsstange
nach unten.
Bild 2.4 (Y = 4 – 20 mA)
Bei dem steigenden Strom verschiebt
sich die Antriebsstange nach unten.
Bild 2.5 (Y = 0 – 20 mA)
Bei dem steigenden Strom verschiebt
sich die Antriebsstange nach unten.
Bild 2.6 (Y = 10 – 2 V)
Bei dem steigenden Spannung
verschiebt sich die Antriebsstange
nach oben.
Bild 2.7 (Y = 10 – 0 V)
Bei dem steigenden Spannung
verschiebt sich die Antriebsstange
nach oben.
Bild 2.8 (Y = 20 – 4 mA)
Bei dem steigenden Strom verschiebt
sich die Antriebsstange nach oben.
Bild 2.9 (Y = 20 – 0 mA)
Bei dem steigenden Strom verschiebt
sich die Antriebsstange nach oben.
3. Elektrisches Schaltbild (Bild 3)
3.1 Steuersignal
Signal von dem Regler wird auf die
Klemmen SN und Y angeschloßen.
3.2 Ausgangssignal
Ausgangssignal auf der Klemme X
kann zum Anzeigen von
Ventilsposition verwendet werden.
Asgangssignal hängt von der
Einstellung der Brücke 2/0 (2 – 10 V
oder 0 – 10 V) ab.
3.3 Anschlußspannung
Anschlußspannung (24 V~ ± 10%,
50 Hz) wird auf die Klemmen SN und
SP angeschloßen.
4. Ventilhubindikator (Bild 4)
5. Funktion
Nach der Einschaltung der
Anschlußspannung wird die
Selbsteinstellung durchgeführt
(Anpassung auf das gewählte Ventil).
Die Signallampe blinkt so lange bis
die Selbsteinstellung beendet wird.
Die Dauer des Prozesses hängt vom
Hub ab und wird normalerweise in
einigen Minuten beendet. Nach der
Selbsteinstellung wird die Hublänge
gespeichert.
Selbsteinstellung soll die RESET Taste
betätigt werden (Bild 2).
Bei dem Ausfall der
Versorgungsspannung wird die
Ventilposition gespeichert.
Wiederholte Selbstjustierung ist in
diesem Fall nicht nötig.
Bemerkung: Um einen demontierten
Stellantrieb wieder auf das Ventil
anzupassen, muß die
Selbsteinstellung wiederhalt werden!
5.1 Fern-Selbsteinstellung
Zur Einführung der
Fern-Selbsteinstellung wird die
Brücke A unterbrochen und
follgendes Verfahren durchgeführt:
- schalten Sie die Anschlußspannung
aus
- schalten sie die Anschlußspannung
ein und schalten Sie sie noch
einmal aus innerhalb von 5 bis 8
Sekunden.
- wiederholen sie noch einmal das
oben beschriebene Verfahren.
Bei der nächsten Einschaltung
führt der Antrieb die
Selbsteinstellung durch.
Bemerkung: RESET Taste wird auch
nach der Unterbrechung der
Brücke A funktionsfähig.
6. Übersteuerung der Reglerfunktion
(direkte Funktion) (Bild 3)
Wenn die Klemme 2 länger als 0.1 s
an die Klemme SN angeschloßen
wird, wird der Antrieb unabhängig von
dem Steuersignal Y in die obere
Position verschoben. Wenn die
Klemme 3 länger als 0.1 s an die
Klemme SN angeschloßen wird, wird
der Antrieb unabhängig von dem
Steuersignal Y in die untere Position
verschoben.
Bemerkung: Bei direkter Funktion ist
der Wert des Signals X nicht genau
so lang bis der Antrieb die Endlage
erreicht. Positionierungsanlage hat
keine Rückverbindung und deshalb
kann zu einem Fehler bei der
Positionierung führen. Das könnte
vermieden werden, so daß der
Antrieb bei der direkten Funktion in
die Endposition verschoben wird. In
diesem Fall werden tatsächliche und
relative Position des Antriebs
gleichgestellt.
Warnung: Verwechslung von Klemmen
SN und SP bei der direkten Funktion
zerstört die Platine.
7. Funktionsindikation
LED ausgeschaltet
- kein Betrieb oder keine
Versorgungsspannung
LED eingeschaltet
- Normalbetrieb
LED blinkt (1 Hz)
- Selbseinstellung
LED blinkt (3 Hz)
- mögliche Fehler:
• Unreichende
Versorgungsspannung
• Ungenügender Hub (< 20 s bei
50 Hz bzw. < 17 s bei 60 Hz)
• Endposition wird nicht erricht.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5