Dry contact for RS-485 Owner’s & installation manual
TABLE OF CONTENTS
n Safety Precautions
.............................................................
3~5
n Specification
............................................................................
6
n Name of each part
..................................................................
7
n Installation Method
...........................................................
8~10
n Setting method......................................................................11
1. Connecting Drycontact with Indoor unit
PCBA and Modbus Controller............................................................11
2. Setting Address ..................................................................................11
Safety Precautions
Installation manual 3
ENGLISH
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions
must be followed.
n Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is
classified by the following indications.
n Meanings of symbols used in this manual are as shown below.
WARNING
CAUTION
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage.
Be sure not to do.
Be sure to follow the instruction.
WARNING
n Installation
Service
Center
Service
Center
Don’t touch with the hands
while the power is on.
• Cause fire, electric shock,
explosion or injury.
Product installation must
be referred to a service
center or installation shop.
• Cause fire, electric shock,
explosion or injury.
Request installation from
installation shop or service
center when reinstalling
the product.
• Cause fire, electric shock,
explosion or injury.
Safety Precautions
4 Modbus Gateway For Indoor Unit
Standardized
product
Do not install the product
in the place where rain can
get to the product.
• Cause product failure
Do not install the unit in
humid locations.
• Cause product failure
Do not put the product
closer to fire.
• Cause fire
Do not install in a place
that cannot withstand the
weight of the product.
• The product may get
damaged or may break.
Do not install the product
to a place that generates
oil, steam, salt, sulfuric
gas, etc.
• Cause the product’s
deformation or failure.
Use standardized Product.
• Cause product failure
Do not change or extend
power lines arbitrarily.
• Cause fire or electric shock.
Do not give a shock to the
product.
• If you give a shock to the
product, it may cause the
product’s failure.
Do not use a heater near
the power line.
• Cause fire or electric shock.
n Operation
Safety Precautions
Installation manual 5
ENGLISH
Service
Center
STOP
Do not spill water inside of
the product.
• Cause electric shock or
breakdown.
If the product has been
inundated, you must refer to
a service center or
installation shop.
• It can cause a fire.
Children and elderly use the
product under the
guardian’s supervision.
• Cause accidents and product
failures.
Do not use for special
purpose / place such as
conserving flora and fauna,
precision instruments, art.
• Otherwise, it can cause property
damage.
Remove the power plug
when cleaning.
• Cause fire or electric shock.
Do not place heavy objects
on the power line.
• Cause fire or electric shock.
Do not disassemble, repair,
or modify the product.
• Cause fire or electric shock.
Do not touch with wet
hands.
• Cause fire or electric shock.
Specification
Specification
6 Modbus Gateway For Indoor Unit
1) Modbus configuration
- Network : 2 wire RS485
- Mode : Modbus RTU slave
- Baud : 9600
- Parity : None
- Stop bits : 1
- Register Base : 0
2) Data registers
Register Name Range Notes
1 Operation 0 ~ 1
0 : Stop
1 : Run
30003 Indoor temperature 100 ~ 400 Degrees C × 10
30100 Error alarm 0 ~ 1
0 : No Error
1 : Error
40001 Set Run Mode 0 ~ 4
0 : Cooling
2 : Fan
3 : AI
4 : Heating
40002 Set Temperature 180 ~ 300 Degrees C × 10
40015 Set Fan Speed 1 ~ 3
1 : Low
2 : Middle
3 : High
Installation manual 7
Name of each part
Modbus Gateway For Indoor Unit
Name of each part
PCB
Front Case Rear Case
ISO View
Side
Cable(1 EA)
(For Connecting with indoor unit)
Installation Manual
Side
12
ON
34
1
2
3
4
765
* Others :
Screw 4 EA(For installation)
1. CN-OUT :
2. BUS-A :
3. BUS-B :
4. SW1 :
5. SWDIP :
6. LED1 :
7. LED(01~03)G :
ENGLISH
Indoor Unit Connector
RS-485(+) Terminal
RS-485(-) Terminal
Reset Switch
Setting Address Switch(Refer Page 11)
RS-485 Status LED
Communication Status LED
8 Modbus Gateway For Indoor Unit
Installation Method
Installation Method
Installation inside of the indoor unit
1) Loosen and remove two screws that secure the product.
2) Loosen two screws that secure the PCB to separate rear of the case from the PCB.
3) Connect the connection wires properly according to the connection method. (Refer to the instruction
and set-up description)
4) Set the switch according to the setting method. (Refer to the instruction and set-up description)
5) Secure PCB on adequate space inside of the indoor unit.
1. Install the product on flat surface and install anchoring screws at more than 2 places. Otherwise
the central controller may not be anchored properly.
2. Do not tighten anchoring screws too tightly. It may cause deformation of the case.
3. Do not deform the case at random. It may cause malfunction of the central controller.
Installation manual 9
ENGLISH
Installation Method
Installation
1) Loosen and remove two screws that secure the
product.
2) Position the rear case to the direction towards to the
connector for convenient cable arrangement.
3) Secure the rear case on the installation place using the
supplied fixing screws.
4) Remove knock out shapes on the rear case according
to the connector’s size and direction.
10 Modbus Gateway For Indoor Unit
Installation Method
5) Connect the connection wires properly according to the connection method. (Refer to the instruction
and set-up description)
6) Set the switch according to the setting method. (Refer to the instruction and set-up description)
7) Tighten the fixing screws on the top and bottom of the case.
1. Install the product on flat surface and install anchoring screws at more than 2 places. Otherwise
the central controller may not be anchored properly.
2. Do not tighten anchoring screws too tightly. It may cause deformation of the case.
3. Do not deform the case at random. It may cause malfunction of the central controller.
Installation manual 11
ENGLISH
Setting method
Setting method
1.
Connecting Drycontact with Indoor unit PCBA and Modbus Controller
2. Setting Address
After change any Dry contact setting, then you must press RESET switch to reflect the setting.
h In case, connect a Modbus controller with several product, Address have to be set different from
others.
Indoor unit PCBA
CN_CC
12
ON
34
Modbus
Controller
12
ON
34 12
ON
34
12
ON
34 12
ON
34
12
ON
34 12
ON
34
*Status of switch
12
ON
34 12
ON
34
Address 1 Address 2
Address 3 Address 4
Address 5 Address 6
Address 7 Address 8
ON
OFF
12
ON
34
12 Modbus Gateway For Indoor Unit
12 Gateway Modbus per unità interna
12 Gateway Modbus para Unidade Interior
Specificatie
Specificatie
6 Modbus Gateway voor binnenunit
1) Modbus-configuratie
- Netwerk: 2 draads RS485
- Modus: Modbus RTU slave
- Baud: 9600
- Pariteit: geen
- Stop bits: 1
- Register Basis: 0
2) Dataregisters
Register Naam Bereik Opmerkingen
1 Werking 0 ~ 1
0: Stop
1: werking
30003 Binnentemperatuur 100 ~ 400 Graden C × 10
30100 Foutalarm 0 ~ 1
0: Geen fout
1: Fout
40001 Ingestelde werkingsmodus 0 ~ 4
0: Koelen
2: Ventilator
3: AI
4: Verwarmen
40002 Ingestelde temperatuur 180 ~ 300 Graden C × 10
40015
Ingestelde
ventilatorsnelheid
1 ~ 3
1: Laag,
2: Midden
3: Hoog
12 Modbus Gateway voor binnenunit
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168

LG PDRYCB500.ENCXLEU Owner's manual

Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI