Acco Europe 21076/1 Operating instructions

Type
Operating instructions
1.0m
Vari-focal
Lens
3
324×416×445mm
4.9Kg
7.9Kg
Kg
On/Off Switch
Lamp Change Slider
Reflective Fresnel Lens
Column Release Catch
Euro Plug Socket
C
E
B
H
REFLECTIVE
OVERHEAD
PROJECTOR
REFLECTIVE
OVERHEAD
PROJECTOR
OPERATING INSTRUCTIONS
Thank you for purchasing our Overhead Projector.
Please read these instructions carefully before use.
Part No.- 21076/1
FEATURES
SPECIFICATION
DISTANCE FROM SCREEN CHART
3.30m
1.76m
1.30m
3.0m
1.5m
807... - 110 110V
110V
919... - 110
807... - 220 220/230V
220/230V
A1/223
24V 250W
3.15A
5 x 20mm
919... - 220
807... - 230 230V
230V
919... - 230
807... - 240 230V U.K.
230V U.K.
919... - 240
F
G
H
J
K
A
B
C
D
E
Mirror
Lamp Removal Cover
Varifocal Lens
Column
Head Unit
A
F
G
K
J
D
3
1
2
5
4
6
UNPACKING, ASSEMBLY & SET UP
UNPACKING & ASSEMBLY
SET UP
MAINTENANCE & CARE
REPLACING THE FUSE
FEATURES
1)
2)
3)
4)
1)
2)
The Euro-socket is fitted with a fuse. If you suspect a blown fuse the procedure for replacement
is as follows:-
1)
2)
3)
4)
5)
1)
2)
3)
Carefully remove OHP from packaging. (Complete and return guarantee card. UK only).
Unfold OHP from flat position by lifting and rotating column (E) towards the vertical and
rotating head unit (C). (Refer to Diagram 2).
Rotate Column (E) until fully vertical ensuring column release catch (J) engages. Rotate
head unit (C) to the horizontal position. (Refer to Diagram 3).
Raise mirror (A) to approximately 45° (see Diagram 4 for correct position). Firmly insert
plug (refer to Diagram 6) into OHP socket (refer to Diagram 5) and connect to electricity
supply.
Switch projector on using ON/OFF switch (F). Move projector forward or backward to
obtain the desired picture projection size.
Place transparency on reflective fresnel lens (H) and rotate lever on vari-focal lens (D)
until projected image is clear and sharp.
Switch off OHP at ON/OFF switch (F) and at mains socket.
Disconnect the Euro-plug from the Euro-socket.
Pull out the fuse draw (diagram 5).
Lift out suspect fuse and replace with another of the specified type.
Close fuse holder draw. Reconnect Euro-plug to Euro-socket. The OHP is now ready for use
ON/OFF switch (F).
Lamp removal cover (B) allows the access to the lamp holders within the head unit (C) so
that failed lamps may be
WARNING - switch off machine and allow to cool before changing lamps.
Lamp change slider (G) allows immediate replacement with a second lamp if lamp
fail. Switch off projector using switch (F) and slide lever (forward and along slot)
to lamp two position).
replaced. (Refer to section ‘REPLACING THE LAMP’).
one
should
YOUR PROJECTOR IS NOW READY TO BE SWITCHED ON.
WARNING! - THIS APPLIANCE MUST BE EARTHED.
IF IN DOUBT CONSULT A QUALIFIED ELECTRICIAN
REPLACING THE LAMP
CLEANING
SAFE GUARDS
1)
2)
3)
4)
5)
6)
7)
8)
9)
10)
11)
Periodic cleaning of the OHP is recommended as some components may have their
performance impaired by enviromental conditions. The following procedure should be
followed:-
1)
2)
3)
4)
5)
6)
1)
2)
3)
4)
5)
6)
7)
8)
9)
10)
11)
Switch off OHP at ON/OFF switch (F) and at mains socket.
Disconnect the Euro-plug from the Euro-socket.
Allow OHP to cool before attempting lamp replacement.
Slide back button and open lamp removal cover (B). (Refer to Diagram LR1 & LR2).
Rotate mirror mounting assembly (which is situated above the lamps) out of head unit.
(Refer to Diagram LR3).
Remove the lamp from the lamp holder and discard of properly.
WARNING - Beware of sharp edges on the surrounding metalwork.
Install a new lamp of the specified type using the handling procedures described by the
lamp manufacturer.
Confirm lamp element is positioned centrally over the lamp box mirror and adjust
appropriately.
Close the mirror mounting assembly and ensure it is lying flat.
Close the lamp removal cover (B) and reset the lamp change slider (G) to position ‘lamp 1’.
Reconnect the Euro-plug. The OHP is now ready for use.
Switch off OHP at ON/OFF switch (F) and at mains socket.
Disconnect the Euro-plug from the Euro-socket.
Allow OHP to cool.
Head unit - the mirror surface (A) should be wiped with a soft, lint free cloth.
N.B. - avoid scratching the mirrors surface.
The vari-focal lens should be wiped with a soft, lint free cloth.
The reflective fresnel lens (H) may be cleaned with a soft cloth and a mild non-abrasive
cleaning solution.
DO NOT obstruct the air vents.
DO NOT leave the OHP unattended when switched on, especially when the OHP is used
near children.
DO NOT touch any part of the OHP that may become hot.
DO NOT touch any parts of the OHP if the power cables are damaged or if the OHP has
been dropped and damaged in any way. In these circumstances a qualified person should
check the OHP before use.
DO NOT leave the power cable where it can be tripped over or pulled. Make sure it does
not come into contact with any hot surfaces such as pipes or radiators. Make sure the
cable is not squashed or pinched.
DO NOT leave the OHP plugged in when not in use. Always unplug before cleaning or
servicing.
DO NOT immerse OHP in water or other liquids.
DO NOT store in direct sunlight.
DO NOT leave OHP switched on with mirror plate (A) in the down/closed position.
ONLY use the OHP for the intended purpose.
ONLY replace failed components with those of the recommended type.