Installation instructions for xs.uni potential-free circuit board
GB
Dynamic xs.uni
Operator system for industrial doors
2 Installation instructions for xs.uni potential-free circuit board, Dynamic xs.uni GB (#103563)
1. Meaning of symbols . . . . . . . . . . . . . . . . . . . . . . . . .2
2. Table of contents . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
3. General safety advice . . . . . . . . . . . . . . . . . . . . . . . .3
4. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
5. Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
5.1 Overview of operator control . . . . . . . . . . . . . .5
5.2 Overview of connections . . . . . . . . . . . . . . . . .6
Caution!
Danger of personal injury!
The following safety advice must be observed
at all times so as to avoid personal injury!
Attention!
Danger of material damage!
The following safety advice must be observed
at all times so as to avoid material damage!
Advice / Tip
Check
Reference
i
Advice
2. Table of contents1. Meaning of symbols
Installation instructions for xs.uni potential-free circuit board, Dynamic xs.uni GB (#103563) 3
Attention!
- To avoid damage, it is essential that the
following points be observed:
- The local protection regulations are to be
complied with at all times.
- - The mains cables and control cables MUST
be laid separately.
- To maintain the specified protection category
of the operating system, the cables must be
fitted with the correct gaskets.
Caution!
Danger of electric shock:
Before cabling works commence, a check must
be carried out to ensure that the cables are at
zero voltage.
Measures must be taken to ensure that the
cables remain dead for the duration of the
works (e.g. prevent the power supply from
being switched back on).
Exchanging the circuit board and positioning box
(only carry out if conversion to potential-free limit switches
is required)
4. Installation
• Loosen the screws on the housing cover.
• Remove the housing cover.
• Disconnect all plug-in connections on the existing circuit board.
• Remove the existing positioning box.
Caution!
It is important to follow the instructions for the
door operator when carrying out any installation
work.
Pay particular attention to the general safety
advice!
3. General safety advice
4.1 / 1
Advice:
For operator models xs.uni ES (see type plate), it
is not necessary to exchange the circuit board
and positioning box.
In this case it is only necessary to refer to and
observe the control unit overview diagrams and
tables in section 5.
4. Installation
4 Installation instructions for xs.uni potential-free circuit board, Dynamic xs.uni GB (#103563)
4.1 / 6
4.1 / 5
• Put the cover plate back on.
• Install the new circuit board.
• Set up all previous connections to the new circuit board.
• Connect the cable harness on the on the motor unit side to
XR31 (previously to XM84) on the new circuit board.
• Put the housing cover back in place after completing all the
connection work.
4.1 / 2
• Attach the new positioning box.
• Dismantle the existing circuit board.
4.1 / 3
• Remove the cover plate.
XM84
XR31
4.1 / 4
• Disconnect the cable connector for cable XM84.
5. Overview
Label Type / function
A Positioning box
B Not in use
C Control wheel for CESD-STOP door position
D Not in use
E Control wheel for door CLOSED position
F Control wheel for door OPEN position
G Control wheel for emergency CLOSE door position
H Not in use
I Control wheel for emergency OPEN door position
J Not in use
K Control wheel for “no position” button
L PE connection
5.1 / 7
Control xs.uni 1-phase and 3-phase model
A
B
D
L
XV37
XV38
XV59C
XV36
XV59A
XV55
XV59B
XR31
XM81C
XM81A
H
J
C
E
F
G
I
K
XM89
XM81B
XR51
Installation instructions for xs.uni potential-free circuit board, Dynamic xs.uni GB (#103563) 5
Label Type / function
i
XM81A
Motor connection
(on the motor unit side)
5.2.1 / 1
5.2.1 / 2
XM81B
Motor connection
(on the control unit side)
5.2.1 / 1
5.2.1 / 2
XM81C
Motor connection, delta mode
(on the motor unit side)
XM89
Brake connection
(on the motor unit side -
if available)
XR31
Safety device
(on the motor unit side)
4.1 / 5
XR51
Safety device connection
(on the control unit side)
5.2.1 / 4
XV36
OPEN/CLOSE/CESD-STOP
positioning switch
(on the motor unit side)
XV37
Emergency OPEN/emergency
CLOSE positioning switch
(on the motor unit side)
XV55
Connection of OPEN/CLOSE/
CESD-STOP positioning button
(on the control unit side)
5.2.1 / 3
XV59A
Connection of emergency OPEN
positioning button
(on the control unit side)
5.2.2 / 1
XV59B
Connection of emergency CLOSE
positioning button
(on the control unit side)
5.2.2 / 1
XV59C
Connection of “no position”
positioning button
(on the control unit side)
5.2.2 / 1
5.1 Overview of operator control
5. Overview
6 Installation instructions for xs.uni potential-free circuit board, Dynamic xs.uni GB (#103563)
5.2.1 / 3
Label Type / function
SR15A Thermal overload protection
SR15B Safety switch for emergency hand chain
SR15C Safety switch for release cable
SV56 Positioning switch for door OPEN position
SV57 Positioning switch for door CLOSED position
SV58 Positioning switch for CESD-STOP door position
XR51
Connection of safety device
(on the control unit side)
24V DC 0.5A or 230V
XV55
Connection of OPEN/CLOSED/CESD-STOP
positioning button (on the control unit side)
24V DC 0.5A or 230V
M11E009 / 1
5.2.1 / 4
M11E009 / 2
5.2 Overview of connections
5.2.1 Connection of motor unit
5.2.1 / 1
Label Type / function
MM81A Motor 1N~ 230 V
MM81B Motor 3N~, 400 V star
XM81A Motor connection (on the control unit side)
XM81B Motor connection (on the motor unit side)
XM88 Capacitor connection
M12E002 / 1
5.2.1 / 2
M12E002 / 2
5.2.2 Connection of emergency positioning switches
Installation instructions for xs.uni potential-free circuit board, Dynamic xs.uni GB (#103563) 7
5. Overview
Label Type / function
SV95A Emergency OPEN positioning switch
SV95B Emergency CLOSE positioning switch
SV95C “No position” positioning switch
XV59A
Connection of emergency OPEN positioning button
(on the control unit side)
24V DC 0.5A or 230V
XV59B
Connection of emergency CLOSE positioning
button (on the control unit side)
24V DC 0.5A or 230V
VX59C
Connection of “no position” positioning button
(on the control unit side)
24V DC 0.5A or 230V
5.2.2 / 1
M11E012
Reference:
Refer to the documentation for the door
operator for details of additional connection
work and procedures to be completed before
or during initial operation.
i
Valid from: 12.2012
#103563
1 - GB 360378 - M - 0.5 - 0912
103563
English Original instructions, Copyright.
No part of this manual may be reproduced without our prior consent.
Subject to changes which are in the interest of technical improvements.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Marantec Dynamic xs.uni potfr. Endsch. Owner's manual

Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI