Alcatel-Lucent TEMPORIS 150 User manual

Type
User manual
Alcatel-Lucent– Proprietary
This document contains proprietary information of
Alcatel-Lucent and is not to be disclosed or used except in
Accordance with applicable agreements
Copyright © 2006 Alcatel-Lucent
Unpublished and Not for Publication
All rights Reserved
Alcatel-Lucent VPN Firewall
Brick™ Security Appliance
Model 150
User’s Guide
260-100-001R8.0
Model 150 Brick™ C300698289
User’s Guide C109526590
Issue 2
February 2006
.
Lucent Technologies – Proprietary
Notice
Every effort was made to ensure that this information product was complete and accurate at the time of printing. However, information is subject
to change.
Mandatory customer information
Interference information: Part 15 of FCC rules
NOTE: This equipment has been tested and found to comply with limits for Class B digital device. Pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in accordance with the instruction, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Alteration or modifications carried out without appropriate authorization may invalidate the user’s right to operate the equipment.
Security Statement
In rare instances, unauthorized individuals make connections to the telecommunications network. In such an event, applicable tariffs require that
the customer pay all network charges for traffic. Alcatel-Lucent and its predecessors cannot be responsible for such charges and will not make
any allowance or give any credit for charges that result from unauthorized access.
Trademarks
Alcatel, Lucent, Alcatel-Lucent, and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their
respective owners.
VPN Firewall Brick is a trademark of Alcatel-Lucent.
Limited Warranty
For terms and conditions of sale, contact your Lucent Technologies Account Team.
Ordering Information
The ordering number for this information product is 260-100-001R8.0.
Support
Technical support
Lucent Technologies Customer Technical Assistance Management (CTAM) center provides a technical assistance telephone number that is moni-
tored 24 hours a day. For technical assistance (continental U.S.), call 1-866-LUCENT8 (1-866-582-3688) and select appropriate prompt. For
international customers, please call +1 630-224-4672.
Developed by Lucent Technologies.
Alcatel-Lucent VPN Firewall Brick™ Model 150
Lucent Technologies – Proprietary
Table of Contents
1.
Introduction ..........................................................................................................................................1
1.1. General ........................................................................................................................................1
1.2. Lucent Security Management Server (LSMS) Software Patch ................................................... 1
1.3. Power Supply............................................................................................................................... 1
1.4. USB Port...................................................................................................................................... 1
1.5. LED Indicators ............................................................................................................................ 2
1.6. Handling Brick Components .......................................................................................................2
2. Installation............................................................................................................................................ 2
3. Illustrations........................................................................................................................................... 6
4. Specifications ....................................................................................................................................... 8
4.1. Dimensions.................................................................................................................................. 8
4.2. Processor Memory....................................................................................................................... 8
4.3. LAN Interfaces ............................................................................................................................8
4.4. Performance.................................................................................................................................8
4.5. Virtualization............................................................................................................................... 8
4.6. VPN ............................................................................................................................................. 8
4.7. Mean Time Between Failure .......................................................................................................8
4.8. Hardware Assisted Encryption ....................................................................................................8
4.9. Other Ports................................................................................................................................... 8
4.10. Cooling ........................................................................................................................................ 9
4.11. Altitude........................................................................................................................................ 9
4.12. Environmental .............................................................................................................................9
4.13. Power........................................................................................................................................... 9
4.14. Product Safety and Emissions Certifications............................................................................... 9
5. Safety Instructions.............................................................................................................................. 10
6. Maintenance ....................................................................................................................................... 12
6.1. Replacement of Air Filter.......................................................................................................... 12
6.2. Alarm Indication........................................................................................................................ 12
Table of Figures
Figure 1: Brackets for mounting on a 19-inch rack with 5 inch uprights .....................................................3
Figure 2: Brackets for mounting on a 19-inch rack with 3 inch uprights .....................................................4
Figure 3: Brackets for wall mounting ........................................................................................................... 5
Figure 4: Front View..................................................................................................................................... 6
Figure 5: Rear View...................................................................................................................................... 7
Figure 6: Air Filter Replacement ................................................................................................................ 12
Alcatel-Lucent VPN Firewall Brick™ Model 150
Lucent Technologies – Proprietary
Alcatel-Lucent VPN Firewall Brick™ Model 150
1
Lucent Technologies – Proprietary
1. Introduction
1.1. General
A Model 150 Brick
®
measures approximately 11” (W) x 7.18” (D) x 1.75” (1U) and is intended to be pri-
marily a desktop unit. However, two rack-mounting brackets and two wall-mounting brackets are in-
cluded for different mounting options.
The Model 150 contains four 10/100baseTX ports.
The front panel has Power and HD Activity indicator lights and an Alarm light, as well as a link and an
activity indicator for each of the four Ethernet ports. See Figure 4 for a depiction of the front panel and
Paragraph 1.5 for a description of the light indications.
The rear panel has four 10/100baseTX interfaces on the motherboard, which are labeled 0 through 3. The
panel also has serial, USB (2) and monitor ports and a power jack. See Figure 5 for a depiction of the rear
panel.
NOTE
For installation into networks that are subject to surges, a shielded ethernet cable and/or
serial port cable may be needed for regulatory compliance.
1.2. Alcatel-Lucent Security Management Server (SMS) Software Patch
The Model 150 Brick is only supported by SMS, Version 7.2 or later. To upgrade V7.2 with a software
patch incorporating the Model 150 software, download the latest patch from the following URL:
https://www.vpn.firewall.brick.alcatel-lucent.com/
1.3. Power Supply
The Model 150 comes with a 12 volt external power supply.
1.4. USB Port
The Model 150 has a USB port for a flash drive or external floppy drive.
If a USB floppy drive is to be used, it is recommended that a USB floppy drive with a data transfer rate
of 500Kb/s or more be used to obtain a reasonable download speed. A drive that meets this criterion is
orderable from Lucent Technologies. Contact your sales representative for further information.
If a USB flash drive is to be used, it must be one that is 1)less than 128MB in size, and 2)guaranteed from
the manufacturer to be able to function as a bootable device when formatted as FAT. Due to the variety
of USB flash drives that are commercially available, and the internal differences between flash drives that
seem to be identical from an external view – Lucent Technologies only qualifies that the UsB flash drive
orderable from Lucent Technologies will work properly. The user assumes all liability when using any
USB flash drive other than the one available from Lucent Technologies. Contact your sales representa-
tive for further information.
Alcatel-Lucent VPN Firewall Brick™ Model 150
2
Lucent Technologies – Proprietary
1.5. LED Indicators
Power Light – this light stays green as long as the main power supply is providing power to the
Brick. When power is lost, the light will go out.
HD Activity Light – this light will flash green when activity is detected on the hard drive.
Alarm Light – this light will be off during normal operation. When the temperature of the CPU
exceeds specified limits, the CPU power supply will be turned off and this light will be red.
When this occurs, the Brick is not functional although the Power, HD Activity, Ethernet Link,
and Ethernet Activity lights may still be green. See Paragraph 6.2 for maintenance procedures to
be performed if the Alarm light is red.
Ethernet Link Lights – these lights will be solid green as long as a link is established on the port.
If there is no link, the light will be off.
Ethernet Activity Lights – these lights will flash green when activity on the port is detected.
1.6. Handling Brick Components
To prevent damage to components from electrostatic discharge, always follow the proper guidelines for
equipment handling and storage. Electronic devices can be easily and permanently damaged due to elec-
trostatic discharge during installation and removal.
In order to reduce the static potential, the user should be properly grounded through the use of an ap-
proved antistatic wrist strap when installing, removing or handling Bricks.
2. Installation
To install a Brick, follow the steps below:
1. Remove the Brick from the carton in which it was shipped. If using as a desktop unit, place on a
flat surface near an AC outlet.
2. The standard 19-inch rack-mount kit consists of a left and right mounting bracket designed for
both 1" and 1-1/4" mounting hole spacing. The Brick 150 is intended to be installed in a EIA 19"
Standard Rack with either 5" deep uprights (see Figure 1) or 3" deep uprights (see Figure 2). The
Brick 150 can also be installed in a Telecom Network Bay using 19" to 23" rack adapters.
3. For either wall or rack installation, mount the two brackets using two M5 x .8 x 8 mm panhead
screws per bracket. Figure 1 shows the mounting for a 5” deep upright and Figure 2 shows the
mounting for a 3” deep upright (front of unit is flush with the front of the upright). Figure 3
shows the mounting for a unit to be wall-mounted.
Alcatel-Lucent VPN Firewall Brick™ Model 150
3
Lucent Technologies – Proprietary
Figure 1: Brackets for mounting on a 19-inch rack with 5 inch deep uprights
Alcatel-Lucent VPN Firewall Brick™ Model 150
4
Lucent Technologies – Proprietary
Figure 2: Brackets for mounting on a 19-inch rack with 3 inch deep uprights
Alcatel-Lucent VPN Firewall Brick™ Model 150
5
Lucent Technologies – Proprietary
Figure 3: Brackets for wall mounting
4. Mount the unit on the rack using two screws per bracket or on the wall using one screw per
bracket.
5. Take the power cord that comes with the unit and connect it to the back. See Figure 5 for the lo-
cation of the power jack.
6. Connect the LSMS to one of the Ethernet interfaces on the back (see Figure 5). The following ex-
plains the type of Ethernet cable to use:
Direct connection
If you are connecting the LSMS directly to the Brick, use a crossover Ethernet cable.
Hub/Switch
If you are connecting the Brick to the LSMS by means of a hub or switch, use regular
Ethernet cables from the LSMS to the hub/switch, and from the hub/switch to the interface
on the back.
7. Connect the LANs to the Brick. Insert the Ethernet cable from the LANs into the remaining
Ethernet interfaces (see Figure 5).
Keep a record of the interfaces to which the LSMS and the various LANs are connected. You will
need this information later when you create security zones and assign them to interfaces.
8. Power the Brick up. It is now ready to be configured, using the LSMS (refer to Configuring and
Activating a Brick
®
in the LSMS Administration Guide for instructions).
Alcatel-Lucent VPN Firewall Brick™ Model 150
6
Lucent Technologies – Proprietary
3. Illustrations
Figure 4: Front View
Alcatel-Lucent VPN Firewall Brick™ Model 150
7
Lucent Technologies – Proprietary
Figure 5: Rear View
Alcatel-Lucent VPN Firewall Brick™ Model 150
8
Lucent Technologies – Proprietary
4. Specifications
4.1. Dimensions
Height: 1.75 inches (4.5 cm) (1U)
Width: 11 inches (27.9 cm)
Depth: 7.18 inches (18.2 cm)
Weight: 3 lbs. (1.4 Kg)
Shipping Weight: 5 lbs. (2.3 Kg)
Rack or Wall Mountable
4.2. Processor Memory
650 MHz Celeron Processor with 128 MB of RAM
4.3. LAN Interfaces
Four 10/100base TX Ethernet Ports
4.4. Performance
For information on the Model 150 Brick
®
performance specifications, please access the
following website: https://www.vpn.firewall.brick.alcatel-lucent.com
4.5. Virtualization
Maximum number of virtual firewalls: 150
Number of VLANs supported: 4,094
VLAN domains: up to 4
4.6. VPN
For information on the maxium number of dedicated VPN tunnels, please access the following
website: https://www.vpn.firewall.brick.alcatel-lucent.com
4.7. Mean Time Between Failure
218,999 hours
4.8. Hardware Assisted Encryption
Built-in accelerator chip
4.9. Other Ports
SVGA Monitor
DB9 Console
USB (2)
Alcatel-Lucent VPN Firewall Brick™ Model 150
9
Lucent Technologies – Proprietary
4.10. Cooling
CPU
Chassis
Power Supply
4.11. Altitude
Up to 13,123 feet (4,000 m.)
4.12. Environmental
Operating
Temperature: 0° to 50° C.
Shock: 2.5g. at 15 – 20 ms on any axis
Relative Humidity: 10 – 95% at 40 C. (non-condensing)
Vibration: 5g. at 2 – 200 Hz on any axis
Non-Operating
Temperature: -20° to 70° C.
Shock: 35g. at 15 – 20 ms on any axis
Relative Humidity: 10 – 95% at 40 C. (non-condensing)
Vibration: 5g at 2 – 200 Hz on any axis
4.13. Power
External AC to DC Power Supply
Rated 50W max.
Input
CV mode, 100 – 240 VAC, 47 to 63 Hz, 64 watts
Typical Consumption
0.28A @ 115V, 0.14A @ 230V
4.14. Product Safety and Emissions Certifications
Safety Listings
USA/Canada: CSA Certified to UL60950-1, First Edition and
CAN/CSA C22.2 No. 60950-1-03
EU: CE, CB Scheme to EN/IEC 60950
EMC Certifications
USA: FCC Part 15, Class B, CISPR Pub. 22 Class B
Canada: ICES-003 Class B
EU: EN 300-386 V1.3.2; EN 55024, EN 55022 Class B
Japan: VCCI, Class B
ICSA Certification
ICSA V4.0 Firewall Certified
ICSA V1.0B IPSec Certified
Alcatel-Lucent VPN Firewall Brick™ Model 150
10
Lucent Technologies – Proprietary
5. Safety Instructions
The exclamation point within an equilateral triangle is intended to alert the user to the
presence of important operating and maintenance (servicing) instructions in the
literature accompanying the product.
When installing, operating, or maintaining this equipment, basic safety precautions should always be
followed to reduce the risk of fire, electric shock, and injury to persons, including the following:
Read and understand all instructions.
Follow all warnings and instructions marked on this product.
For information on proper mounting instructions, consult the Installation Instructions in this manual.
Do not place this product on an unstable cart, stand or table. The product may fall, causing serious
damage to the product.
This product should be operated only from the type of power source indicated on the marking label.
If you are not sure of the type of power supply, consult your dealer or local Power Company.
Unplug this product from the wall outlet before cleaning. Do not use liquid cleaners or aerosol
cleaners. Use a damp cloth for cleaning.
Do not use this product near water, for example, in a wet basement.
Never push objects of any kind into this product through slots as they may touch dangerous voltage
points or short-out parts that could result in a risk of fire or electrical shock. Never spill liquids of
any kind on the product.
Slots and openings in the unit are provided for ventilation, to protect it from overheating, these
openings must not be blocked or covered. This product should not be placed in a built-in installation
unless proper ventilation is provided.
To reduce the risk of electrical shock, do not disassemble this product. Service should be performed
by trained personnel only. Opening or removing covers and/or circuit boards may expose you to
dangerous voltages or other risks. Incorrect re-assembly can cause electric shock when the unit is
subsequently used.
Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to
the instruction.
This product is equipped with a three-wire grounding type plug, a plug having a third (grounding)
pin. This plug is intended to fit only into a grounding type power outlet. This is a safety feature. If
you are unable to insert the plug into the outlet, contact your electrician to replace your obsolete
outlet. Do not defeat the safety purpose of the grounding type plug. Do not use a 3-to-2-prong
adapter at the receptacle. Use of this type adapter may result in risk of electrical shock and/or damage
to this product.
Do not allow anything to rest on the power cord. Do not locate this product where the cord will be
abused by persons walking on it.
Do not overload wall outlets and extension cords as this can result in the risk of fire or electric shock.
!
Alcatel-Lucent VPN Firewall Brick™ Model 150
11
Lucent Technologies – Proprietary
Unplug this product from the wall outlet and refer servicing to qualified service personnel under the
following conditions:
a) When the power supply cord or plug is damaged or frayed.
b) If liquid has been spilled into the product.
c) If the product has been exposed to rain or water.
d) If the product does not operate normally by following the operating instructions. Adjust only
those controls that are covered by the operating instructions because improper adjustment of
other controls may result in damage and will often require extensive work by a qualified
technician to restore the product to normal operation.
e) If the product has been dropped or the cabinet has been damaged.
f) If the product exhibits a distinct change in performance.
Save these instructions for future reference.
Alcatel-Lucent VPN Firewall Brick™ Model 150
12
Lucent Technologies – Proprietary
6. Maintenance
6.1. Replacement of Air Filter
As needed, periodically clean or replace the air filter using the following procedure:
1. Remove the snap-on filter cover from the side of the unit (see Figure 6).
2. Remove the filter and clean or discard. If filter cannot be cleaned, replace with part number
408905024.
3. Replace the cleaned (or new) filter.
4. Replace the snap-on filter cover.
Snap-on
Filter Cover
Filter
Front of Unit
Figure 6: Air Filter Replacement
6.2. Alarm Indication
The Alarm light goes on (red) and the CPU power is turned off when the CPU exceeds operating tempera-
ture limits. The Brick is not functioning when this condition occurs. The CPU may have overheated be-
cause of inadequate ventilation. Clean or replace the air filter, as described in Paragraph 6.1. When the
CPU cools, the power will come back on. If the problem was caused by blockage of the fan, a clean air
filter should resolve the problem. If the problem persists, please call your service representative.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Alcatel-Lucent TEMPORIS 150 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI