CyClone SC722 Installation And Operation Instructions Manual

Category
Cooker hoods
Type
Installation And Operation Instructions Manual

This manual is also suitable for

Self-Cleaning Range Hoods
Models:
Installation and Operation Instructions
Please read all instructions before installing and operating.
All wiring and installation must be in accordance with CEC, NEC and local electrical codes.
READ AND SAVE THESE INSTRUCTIONS
Wall Mount and Island Range Hoods
SC(B)500, SC(B)501, SC(B)502, SC(B)503, SC510,
SC(B)513, SC(B)514, SI(B)323, SI(B)520, SI(B)521,
SI(B)522, SI(B)523, SI530, SI531
SC322, SCB722, SC712, SC(B)715, SCB717,
SCB718, SC720, SC(B)722
2Cyclone Canopy Installation - English
3Cyclone Canopy Installation - English
Important Safety InStructIonS
• isappliancemustbeinstalledbyaqualiedtechnician.
• emanufacturerdeclinesallresponsibilitiesintheeventof
failuretoobservetheinstructionsgivenhereforinstallation,
maintenanceandsuitableuseoftheproduct.
• emanufacturerfurtherdeclinesallresponsibilityforinjury
duetonegligence,andthewarrantyoftheunitautomatically
expiresduetoimproperinstallationandmaintenance.
WARNING
• Forindooruseonly.
• Forgeneralventilationuseonly.Donotusetoexhausthazardous
orexplosivematerialsorvapors.
• Twoinstallersarerecommendedbecauseofthesizeand
weightofthishood.
CAUTION
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Usethisunitonlyinthemannerintendedbythemanufacturer.
2. Before servicing or cleaning the unit, switch power o
atservicepanelandlockservicepaneltopreventpower
from being switched on accidentally. When the service
disconnectingmeanscannotbelocked,securelyfastena
prominentwarningdevicetotheservicepanel.
3. Installationworkandelectrical wiringmustbedoneby
qualiedpersonsinaccordancewithallapplicablecodes
andstandards,includingre-ratedconstruction.
4. Sucientairisneededforpropercombustionandexhausting
of gases through the ue of fuel burning equipment to
prevent back draing. Follow the heating equipment
manufacturersguidelineandsafetystandardsaspublished
bythelocalcodeauthorities.
5. Whencuttingordrillingintowallsorceilings,becareful
nottodamageexistingelectricalwiringandotherhidden
utilities.
6. Toreducetheriskofre,electricshockandtoproperly
exhaustair,ductedfansmustalwaysbeventedoutdoors.
Donotventexhaustairintospaceswithinwalls,ceilings,
attics,crawlspaces,orgarages.Donotconnectthisfan
withanysolid-statespeedcontroldevice.
7. Alwayskeeptheductcleartomaintainproperairowfor
venting.
8. ebottomofthehoodMUSTNOTBELESSthan28”
and at a suggested maximum of 36” above cooktop for
bestcapture ofcookingimpurities.Foragas range,the
bottomofthehoodMUSTNOTBELESSthan30”above
cooktop.
WARNING
TO REDUCE THE RISK OF RANGE TOP GREASE FIRE:
1. Neverleavetherangeunattendedathighsettings.
2. AlwaysturnhoodONwhencookingathighheatorwhen
amingfood.
3. Useproperpansize.Alwaysusecookwareappropriatefor
thesizeofthesurfaceelement.
4. Keep fan, lters and grease laden surfaces clean. Clean
ventilatingfansfrequently.Donotallowgreasetoaccumulate
onfanorlter.
5. UseHIGHsettingonhoodonlywhennecessary.
6. Dontleavehoodunattendedwhencooking.
7. Toreducetheriskofre,useonlymetalductwork.
8. isunitmustbegrounded.
9. Notforoutdooruse.
WARNING
• Donotrepairorreplaceanypartofthisapplianceunless
specicallyrecommendedinthisbook.Allotherservice
shouldbeperformedbyaqualiedtechnician.
• e hood motor has a thermal overload that will
automaticallyshutothemotorifitbecomesoverheated.
emotorwillrestart.Ifthemotorcontinuallyshutso
and restarts, contact the Cyclone service department.
Ensure that the hood is mounted at the recommended
mountingheight.
• isproductmayhavesharpedges.Becarefultoavoid
cutsandabrasionsduringinstallationandcleaning.
WARNING
4Cyclone Canopy Installation - English
contentS
Important Safety Instructions 3
Damage Inspection 4
Ducting 4
Mounting Heights and Clearance 5
Wiring Installation 5
Wall Mount Installation - Tools and Materials Required 6
Wall Mount Installation - Parts Supplied 6
Wall Mount Hood Installation 7
Island Installation - Tools and Materials Required 8
Island Installation - Parts Supplied 8
Island Hood Installation 9
Canopy Hoods Specications 11
Troubleshooting 37
Control Panel 38
Maintenance 38
Cyclone Range Hoods Limited Warranty 39
5Cyclone Canopy Installation - English
Damage InSpectIon
• Pleasefullyinspectunitfordamagebeforeinstallation.
• Iftheunitisdamagedinshipment,returntheunittothestoreinwhichitwasboughtforrepairorreplacement.
• Iftheunitisdamagedbythecustomer,repairorreplacementistheresponsibilityofthecustomer.
• Iftheunitisdamagedbytheinstaller(ifotherthanthecustomer),repairofreplacementmustbemadebyarrangementbetween
customerandinstaller.
• Onceinstalled,alldamageswillbeassumedtheresponsibilityoftheinstaller.
DuctIng
• Toreducetheriskofre,useonlymetalductwork.
• Toreduceriskofreandtoproperlyexhaustair,besure
toductairoutside–donotventexhaustairintospaces
withinwalls,ceilings,attics,crawlspaces,orgarages.
WARNING
• Best to use rigid type metal ducts. Flexible ducts can
restrictairowbymorethan50%.
• Reducethenumberoftransitionsandturnsasmuchas
possible.Ifareducerisused,installalongreducerinstead
ofapancakereducer.Ifturnsandtransitionsarerequired,
installthemasfarawayfromtheopeningaspossibleand
asfarapartbetweentwoaspossible.
CAUTION
• 6”roundductworkmustbeusedtomaintainmaximum
airoweciencywithmotorsof300CFMorgreater.If
theuseofanysizeductingislessthan6”,thewarrantyis
automaticallyvoided.
• eventingductmustgohorizontallyorverticallyuptothe
outsidewallortheroof.Ifitisturneddownwardanywhere
intheventingsystem,thewarrantyisautomaticallyvoided.
WARNING
Fastenallconnectionswithsheetmetalscrewsandtapealljoints
withcertiedsilvertapeorduct.
Donotcutajoistorstudunlessabsolutelynecessary.Ifajoistor
studmustbecutthenasupportingframemustbeconstructed.
Beforemakingcutoutsmakesurethereisproperclearancewithin
theceilingorwallfortheexhaustvent.
Examples of dierent types of ventilation for island
and wall mounted canopies:
Additional parts not provided.
Roof Pitch with Cap
and Flashing
Side wall cap with
gravity damper
Soffit or crawl space
Side wall cap with
gravity damper
6Cyclone Canopy Installation - English
mountIng HeIgHtS anD clearance
• ehoodshouldbeinstalledat28”minimumabovethe
cookingsurface.Ifpairingyourrangehoodwithagas
stoveminimummountingheightmustbe30”abovethe
cookingsurface.
WARNING
Minimum mount height between range top to hood bottom should
benolessthan28”forelectricorceramicstoves,andnolessthan30”
forgasstoves.emaximummountheightshouldbenomorethan
36”.ehoodmustbeinstalledatthecorrectmountingheight.Hoods
mounted too lowcouldresultinheatdamage.Hoodsmountedtoo
high, on the other hand, will be less eective and performance may
suer.
Checkyourceilingheightandthehoodheightmaximumbefore
youselectyourhood.
Hoodinstallationheightabovecooktopistheuser’spreference.
elowerthehoodisabovethecooktopthemoreecientitwill
beindrawingoutcookingodors,greaseandsmoke.
WIrIng InStallatIon
Grounding Instructions
isappliancemustbegrounded.
isapplianceisequippedwithacordhavingagroundingwireor
withaplughavinggroundingwire.egroundingwiremustbe
groundedproperlyinthejunctionboxortheplugmustbeplugged
intoanoutletthatisproperlyinstalledandgrounded.
1. Connectthepowerlinegroundwiretothegreengroundwire
suppliedwiththehood.
2. Connecttheblackpowerwiretotheblackwiresuppliedwith
thehood.
3. Connectthewhiteneutralwiretothewhitewiresuppliedwith
thehood.
Min: 3”
Max. 2 ¾”
Install the Electrical Power Supply
Positiontheoutletorjunctionboxwithinthespacecoveredbythe
ductcover.Placetheoutletorjunctionboxatamaximumdistance
of24”fromwherethecordexitsfromthehood.ecenterofthe
outletorjunctionboxshouldbepositionedat2¾”awayfromthe
centerofthefuturehoodlocation.Makesurethisdoesnotinterfere
withthemountingareaorwiththeductcover.
Min:
Ceramic/Electric
28”
Gas 30”
Max: 36”
36”
Green: Ground
White: Neutral
Black: Power
is appliance requires 120V 60Hz electrical supply and connection to an individual properly grounded branch circuit protected
by a circuit breaker or time delay fuse.
7Cyclone Canopy Installation - English
WALL MOUNT INSTALLATION - PARTS SUPPLIED
1 × Hood 1 × Chimney Flues
(Top and Bottom)
1 × Round Adapter
(May be Pre-Installed)
1 × Upper Mounting Bracket
HARDWARE PACKAGE
4 × Mounting Screws
(Long and Medium, 2 each)
4 × Drywall Anchors
(Large and Small, 2 each)
2 × Washers
1 × Oil Cup
6 × Damper Screws
2 × Top Chimney Screws SC500, SC711, SC715 ONLY:
2 × Bottom Chimney Screws
WALL MOUNT INSTALLATION - TOOLS AND MATERIALS REQUIRED
Electrical drill or ratchet driver
½” drill bit for drilling pilot holes
1 ¼” drill bit for drilling electrical wiring acess
hole (if applicable)
Phillips screwdriver #2 or driver bit
Wire stripper or cutter
Tape measure
Aluminum foil tape and/or duct tape
Electrical supplies for wiring (i.e. marrets,
electrical tape)
Hammer
Jigsaw or saber saw
Drywall stud (if applicable)
Step latter
Stud
Level
1 × Plastic Damper Cover
PRE-INSTALLED
2 or 4 × G4 Type Lights
(12V, 20W)
PLEASE REFER TO PAGES 11-37 FOR YOUR MODEL’S SPECIFICATIONS
8Cyclone Canopy Installation - English
Install the Wall Mount Hood
1. Measure from range top to hood bottom and use a leveler
to mark line A (28” minimum from range top for electric/
ceramicstoves,30”minimumfromrangetopforgasstoves).
2. PlaceandmarkcenterlineC/L.
3. Use the hood fan as template to nd the mounting screws
position. Keep the hood bottom centered and level on line
A.Markthepositionofthetwomountingscrews(Figure1).
Important: e minimum allowable distance from the top of the
damper on range hood to the bottom of the ductwork protruding
from wall is 3”.
4. Fastentwomountingscrewsintostudswherepossibleatthe
positionsmarkedwithanX.Donotfastenscrewsalltheway.
5. Wherestudsarenotavailable,youmustconstructwoodwall
framing that is ush with surface of wall studs. Wood wall
framingshouldbeatleast1/2”thickand3”high.Assemble
wood wall framing to wall studs for a secure installation.
Makesuretheheightoftheframingallowsthehoodfantobe
securedtothewoodblock(Figure2).
6. Centertheuppercovermountingbracketwiththecenterline
andmountitushwiththeceilingbydrillingpilotholesand
usingsmallanchorsprovided(Figure3).
7. Install6”roundadapterifnotpreinstalled.
8. Removetheltersfromthehood.
9. Hang hood onto screws and hand tighten. If possible, use
extrascrewstofurthersecurethehoodtothewallfrominside
thehood.
10. Install 6” round duct over the adapter, connect it with the
ventingductcomingfromthewallorceiling.Usemetalfoil
ducttapetosealthejoint.
11. Installelectricalconnection.Turnonthehoodandcheckfor
leaksaroundducttape.
12. Placetelescopicductcoversontohoodandextendinnertop
ductcoverupwardsandsecuretoductcoverbracket.
13. Reinstall lters to the hood. Remove protective plastic lm
coveringtheductcoversandhood.
• Woodblockingmayneedtobeaddedbehindthedrywall
ifno studsarepresent.Wallanchorsmay also be used,
checklocalcodesbeforeusingwallanchors.
CAUTION
• Whencuttingordrillingintowall,donotdamageelectrical
wiringandotherhiddenutilities.
WARNING
Min. 3”
Min. 1 ½” Framing Behind
Drywall
Wall Studs
C/L
A
Min. 28-30”
Min. 3”
Ceiling
Screw Locations
Mounting Bracket
Flush with Ceiling
Wall mount HooD InStallatIon
• Atleasttwoinstallersarerequiredduetotheweightand
sizeofthehood.
• Turnopowercircuitattheservicepanelbeforewiring
thisunit.
• Allelectricalworkmustbedonebyaqualiedelectrician
in accordance with all applicable codes and standards.
israngehoodmustbeproperlygrounded.
CAUTION
Figure3.
Figure1.
Figure2.
9Cyclone Canopy Installation - English
3 × Mounting Brackets
(Upper and Expandable Side)
HARDWARE PACKAGE
4 × Mounting Screws 4 × Washers 6 × Damper Screws 20 × Mounting Bracket Screws
SI520 ONLY
2 × Bottom Chimney Screws
ISLAND INSTALLATION - PARTS SUPPLIED
1 × Hood 1 × Chimney Flues
(Top and Bottom)
1 × Round Adapter
(May be Pre-Installed)
ISLAND INSTALLATION - TOOLS AND MATERIALS REQUIRED
Electrical drill or ratchet driver
½” drill bit for drilling pilot holes
1 ¼” drill bit for drilling electrical wiring acess
hole (if applicable)
Phillips screwdriver #2 or driver bit
Wire stripper or cutter
Tape measure
Aluminum foil tape and/or duct tape
Electrical supplies for wiring (i.e. marrets,
electrical tape)
Hammer
Jigsaw or saber saw
Drywall stud (if applicable)
Step latter
Stud
Level
PRE-INSTALLED
2 or 4 × G4 Type Lights
(12V, 20W)
1 × Oil Cup 1 × Plastic Damper Cover
PLEASE REFER TO PAGES 11-37 FOR YOUR MODEL’S SPECIFICATIONS
10 Cyclone Canopy Installation - English
Measure Installation Height
Determinetherequireddistancebetweentheceilingandthetopof
theblowerbox(D)baseduponceilingheight(C),desiredheightof
hoodabovecooktop(A)andunitheight(B):
D=C-A-B
e height D is the installation height of the mounting bracket
(Figure3).IftheinstallationheightDislessthan22”,themounting
bracketandductcoversmayneedtobecut.eductcoversneedsa
cleancutandmusttobecutfrombottomendsidesforbothinside
andoutsidepieces.Foroptimalclearance,theminimummounting
shouldbe30”abovethecookingsurface.
C/L
A
C
D
B
Blower Top Box
Range Hood Bottom
• When building framework, always follow all applicable
constructioncodesandstandards.
WARNING
Install Mounting Bracket
1. Modify ceiling structure at hood location. Install 2 × 4
crossframingbetweenceilingjoistsusingceilingmounting
bracketdimension(Figure4).eframeworkmustbesized
tosupportthetotalweightofthehood.
2. Finish ceiling surface. Be sure to mark the location of the
ceilingjoistsandcrossframing.Bringhousewiringthrough
nishedceiling.
10 ½”
11 ¼”
9 ⅝”
8 ¾”
ø 6 ¾”
3 ⅜”
4 ⅜”
1 ⅜”
Upper Mounting
Bracket
Ceiling Joists
Cross Framing
6” Round
Ductwork
ISlanD HooD InStallatIon
• Atleasttwoinstallersarerequiredduetotheweightand
sizeofthehood.
• ishoodshouldbeinstalledtoanishedceiling.
• Turnopowercircuitattheservicepanelbeforewiring
thisunit.
• Allelectricalworkmustbedonebyaqualiedelectrician
in accordance with all applicable codes and standards.
israngehoodmustbeproperlygrounded.
CAUTION
Figure4.
Figure5.
11Cyclone Canopy Installation - English
3. Positiontheceilingmountingplateinsuchawaythatoneof
thesideswiththreescrewholesfacesthefrontofthehood.
Secure mounting bracket to the ceiling using four wood
screws.Ensurethatscrewsaredrivenintothecenterofthe
framing for maximum strength.  Assemble two upper side
bracketstotheceilingmountingbracketusingsixmounting
screws(threeperbracket)(Figure5&6).
4. Use eight screws to mount the lower brackets to the upper
brackets. Determine lower brackets mounting height based
uponinstallationheightDofthemountingbracket.
Install the Island Hood
1. Removetheltersfromthehood;attachtheadapter/damper
tothetopofthehood.
2. Measure the required length of 6” round metal duct from the
adapter/damper to the ductwork rough-in in the ceiling.
Connectthissectionofducttotheadapter/damperandseal
jointwithmetalfoilducttape.
Mounting Screws
3. Slidethelowerandupperchimneyues
over the installed mounting bracket
andhaveasecondpersonholdittothe
ceiling.
4. Attachthehoodtomountingbracketusing
sixscrews(threeperside)(Figure7).
5. Slidethelowerandupperchimneyues
down on top of the hood.  Install the
electrical connection and connect the
duct to the rough-in duct work in the
ceiling. Seal the joints with metal foil
ducttape.
6. Power up hood and check for leaks
aroundducttape.
7. Carefully slide the upper (inner) ue
overuptotheceilingandsecureittothe
mountingplatefrombothsides.
8. Reinstalllterstothehood,peelothe
protectiveplasticlmcoveringtheues
andthehood.
Note: For some models, the “L” shape support frame may be
used (Figure 8). e installation procedures are same except
that the hood is mounted on one side. If need be, use an
adjustable string wire from other side to keep the hood level.
Figure6.
Figure7.
Figure8.
Note: 10 Feet Ceilings
ForSI520,usethemountingbracketsandductcoverssupplied.
For any other models, optional extension mounting brackets
andductcoversneedtobeordered.
12 Cyclone Canopy Installation - English
canopy HooDS SpecIfIcatIonS
WSC300/SC301/SC322/
SI323
SC500/SC501/SC502/
SC503/SC510/SC513/
SC514
SC707/SC712/SC717/
SC718/SC720/SC722/
SC727/SC771
SCB500/SCB501/
SCB514/SC711/SC715
SI520/SI521/SI522/
SI523/SI530/SI531
SIZE 30”/36” 30”/36”
SC500/SC514-24”/30”/36” 30”/36” 30”/36” 36”
SI523-30”/36”
MOUNTING WALL
SI323-ISLAND WALL WALL WALL ISLAND
MAX.
CUBIC FEET/METER
(CFM)
300 550 550 550 550
MAX. SONES 2.5 6666
FINISH STAINLESSSTEEL
STAINLESSSTEEL+GLASS
STAINLESSSTEEL
STAINLESSSTEEL+GLASS
STAINLESSSTEEL
STAINLESSSTEEL+GLASS
STAINLESSSTEEL
STAINLESSSTEEL+GLASS
STAINLESSSTEEL
STAINLESSSTEEL+GLASS
CONTROLS PUSHBUTTON PUSHBUTTON PUSHBUTTON PUSHBUTTON PUSHBUTTON
SPEED LEVELS 33333
DELAY OFF YES YES YES YES YES
LIGHTING 2×12V20W
HALOGEN
2×12V20W
HALOGEN
2×12V20W
HALOGEN
2×12V20W
HALOGEN
2×12V20W
HALOGEN
FILTERS ALUMINUMMESH ALUMINUMMESH ALUMINUMMESH BAFFLE ALUMINUMMESH
EXTENSION DUCT
OPTION
YES,10’+CEILING
SPECIALORDER
YES,10’+CEILING
SPECIALORDER
YES,10’+CEILING
SPECIALORDER
YES,10’+CEILING
SPECIALORDER
YES,10’+CEILING
SPECIALORDER
DUCT 6”ROUNDTOP 6”ROUNDTOP 6”ROUNDTOP 6”ROUNDTOP 6”ROUNDTOP
AC INPUT 120V
60Hz
120V
60Hz
120V
60Hz
120V
60Hz
120V
60Hz
POWER
CONSUMPTION
170W
2.5A
280W
2.5A
280W
2.5A
280W
2.5A
280W
2.5A
MOUNTING HEIGHT 28”-36” 28”-36” 28”-36” 28”-36” 28”-36”
13Cyclone Canopy Installation - English
3 1/4”
Φ 6”
29 ½” or 35 ½”
9 ¼”
1 ¾”
8”
17 ¾”
10 ¼”
Min. 27 ¾”
Max. 45 ¼”
6 ¼”
7 ⅛”
11 ½”
13”
6 ¾”
3 1/4”
FRONT SIDE
TOP BACK
8”
9 ¼”
18 ½”
30”/36”
1 ¾”
10 ¼”
27 ¾”
Max 45 ¼”
17 ¾”
SpecIfIcatIonS
Alito Collection Wall Mount - Model: SC(B)500
14 Cyclone Canopy Installation - English
3 1/4”
Φ 6”
23 ½”
9 ¼”
1 ¾”
8”
17 ¾”
10 ¼”
Min. 27 ¾”
Max. 45 ¼”
6 ¼”
7 ⅛”
11 ½”
13”
6 ¾”
3 1/4”
FRONT SIDE
TOP BACK
8”
9 ¼”
18 ½”
23 ½”
1 ¾”
11
27 ¾”
Max 45 ¼”
17 ¾”
SpecIfIcatIonS
Alito Collection Wall Mount - Model: SC50024
15Cyclone Canopy Installation - English
SpecIfIcatIonS
Alito Collection Wall Mount - Model: SC(B)501
FRONT SIDE
TOP BACK
7 ¾”
10 ½”
Min. 23 ½”
Max. 44 ½”
Min. 23 ½”
Max. 44 ½”
29 ½” or 35 ½”
23 ¼”
19 ¾”
17”
7 ½”
9 ½”
12”
13 ¾”
5 ¼”
3 ¼”
Φ 6”
11 ¾”
21 ½”
11 ¾”
10 ½”
19 ¾”
30”/36”
2 ½”
17”
23 ½”
Max: 44 ½”
16 Cyclone Canopy Installation - English
FRONT SIDE
TOP BACK
7 ¾”
9 ½”
12”
5 ¼”
3 ¼”
Φ 6”
7 ½”
11 ¾” 10 ½”
29 ½” or 35 ½” 19 ¾”
13 ¾”
Min. 23 ½”
Max. 44 ½”
23 ¼” 17”
1 ¾”
10 ½”
11 ¾”
21 ½”
2”
30”/36”
19 ¾”
23 ½”
Max: 44 ½”
SpecIfIcatIonS
Alito Collection Wall Mount - Model: SC(B)502
17Cyclone Canopy Installation - English
SpecIfIcatIonS
Alito Collection Wall Mount - Model: SC(B)503
FRONT SIDE
TOP BACK
7 ¾”
9 ½”
12”
5 ¼”
3 ¼”
Φ 6”
7 ½”
11 ¾” 10 ½”
29 ½” or 35 ½” 19 ¾”
13 3/4”
Min. 23 ½”
Max. 44 ½”
23 ¼” 17”
1 ¾”
10 ½”
11 ¾”
21 ½”
2”
30”/36”
19 ¾”
23 ½”
Max: 44 ½”
18 Cyclone Canopy Installation - English
SpecIfIcatIonS
Alito Collection Wall Mount - Model: SC510
FRONT SIDE
TOP BACK
7 ¾”
9 ½”
12”
5 ¼”
3 ¼”
Φ 6”
7 ½”
11 ¾” 10 ½”
29 ½” or 35 ½” 19 ¾”
13 ¾”
Min. 23 ½”
Max. 44 ½”
1 ¾”
5 ¼”
6 ¼”
14 ½”
1 ¾”
10 ½”
11 ¾”
21 ½”
30”/36”
19 ¾”
23 ½”
Max: 44 ½”
19Cyclone Canopy Installation - English
SpecIfIcatIonS
Alito Collection Wall Mount - Model: SC(B)513
FRONT SIDE
TOP BACK
7 ¾”
9 ½”
13 ½”
5 ¼”
3 ¼”
Φ 6”
7 ½”
11 ¾” 10 ½”
29 ½” or 35 ½” 19 ½”
15 ¼”
Min. 24 ½”
Max. 45 ½”
16 ½”
1 ½”
24 ¼”
1 ½”
1 ½”
1 ½”
10 ½”
11 ¾”
21 ½”
30”/36”
19 ½”
24 ½”
Max: 45 ½”
20 Cyclone Canopy Installation - English
SpecIfIcatIonS
Alito Collection Wall Mount - Model: SC(B)514
FRONT SIDE
TOP BACK
7 ¾”
9 ½”
13 ¼”
5 ¼”
3 ¼”
Φ 6”
7 ½”
11 ¾” 10 ½”
29 ½” or 35 ½” 19 ½”
15”
Min. 23 ½”
Max. 44 ½”
2 ¾”
2 ¾”
10 ½”
11 ¾”
21 ½”
30”/36”
19 ½”
23 ½”
Max 44 ½”
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

CyClone SC722 Installation And Operation Instructions Manual

Category
Cooker hoods
Type
Installation And Operation Instructions Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI