PRASTEL MT50000/2 User manual

Type
User manual
Technical Manual
MT50000/2
MT50000/2-M
MT50000/2 V1.0 English
p.2/14
PRASTEL France SARL
ZI Athélia II, 225 Impasse du Serpolet, 13704 LA CIOTAT Cedex
Tél : 04.42.98.06.06 Fax : 04.42.04.53.51 infos@prastelfrance.fr
SUMMARY
SUMMARY .............................................................................................................................. 2
INFORMATION AND RECOMMENDATIONS ....................................................................... 3
TECHNICAL CHARACTERISTICS ........................................................................................ 4
1) MT50000/2 ................................... 4
2) MT50000/2M ................................ 4
CONNECTING A DEVICE USING THE WIEGAND OR CLOCK & DATA PROTOCOL ...... 5
CONNECTING THE MT50000-EXT4 AND MT15000-EXT-IO MODULES ........................... 6
CONNECTING A CURRENT BREAKAGE AND AN ELECTROMAGNETIC SUCTION
OPERATING BY LACK OF CURRENT ................................................................................. 7
CONNECTING A STANDARD SPACER WITH VOLTAGE EMISSION ............................... 8
CONNECTING A PUSH BUTTON AND MICRO SWITCH BOX 220V .................................. 9
CONNECTING THE MT50000/2 CONTROL UNIT TO THE ETHERNET NETWORK ....... 10
INSTALLATION OF SWAMIGO3 DONGLE ........................................................................ 12
FUNCTIONS OF CONNECTION TERMINALS .................................................................... 13
USE OF RESET BUTTONS .................................................................................................. 14
MT50000/2 V1.0 English
p.3/14
PRASTEL France SARL
ZI Athélia II, 225 Impasse du Serpolet, 13704 LA CIOTAT Cedex
Tél : 04.42.98.06.06 Fax : 04.42.04.53.51 infos@prastelfrance.fr
INFORMATION AND RECOMMENDATIONS
In accordance with the European Directive UTE C00-200 describing the 2004/108 / EC di-
rectives, MT50000 / 2 complies with the standards :
NF EN 50081-1 for electromagnetic emissions and
NF EN 50082-1 for electromagnetic susceptibility.
o Cabling recommendations: the cables used to connect the readers, network and other periph-
erals must be installed in accordance with the instructions describing Level 2 (protected environ-
ment) of standard NF EN 61000-4-4.
o This product must be installed by a qualified company: Incorrect installation and use may re-
sult in risk of electric shock or fire. Before carrying out the installation, read the technical instruc-
tions and follow the recommendations for mounting the product.
o For the 220V version, after turning off the power, all internal capacitors will discharge to a
safe level after 60 seconds under normal conditions. However, in the case of a failure, the
charges can be maintained much longer and adequate precautions should be taken before
handling the product.
MT50000/2 V1.0 ENGLISH
p.4/14
PRASTEL France SARL
ZI Athélia II, 225 Impasse du Serpolet, 13704 LA CIOTAT Cedex
Tél : 04.42.98.06.06 Fax : 04.42.04.53.51 infos@prastelfrance.fr
TECHNICAL CHARACTERISTICS
1) MT50000/2
Maximum consumption ................... 300 mA
Supply voltage ................................ 9 14VDC
Weight with housing ........................ 150g
Case dimensions ............................ 170 x 119 x 40 mm
Operating temperature .................... - 20°C à + 50°C
Control relay .................................... 1A / 12V 1A / 24V
2) MT50000/2M
Weight with housing ........................ 2.5Kg
Case dimensions ............................ 345 x 275 x 80mm
Operating temperature .................... - 20°C à + 50°C
Integrated 220V power supply:
Output voltage ................................. 12V
Maximum output current ................. 3A
Battery connection .......................... 13,6V
MT50000/2 V1.0 ENGLISH
p.5/14
PRASTEL France SARL
ZI Athélia II, 225 Impasse du Serpolet, 13704 LA CIOTAT Cedex
Tél : 04.42.98.06.06 Fax : 04.42.04.53.51 infos@prastelfrance.fr
CONNECTING A DEVICE USING THE WIEGAND OR CLOCK & DATA
PROTOCOL
Information :
5 wires (3 pairs recommended)
Max Distance: 100m
Cable type: 0,6mm (SYT advisable)
Screen on cable: Optional
Warning : Do not wire the center-reader link wires near other cables with high voltages or cur-
rents, especially 220V or higher.
Note : Each reader can accept a different technology (example: Reader 1 in Wiegand, Reader 2 in
Clock & Data).
Attention : Si vous utilisez une alimentation
extérieure pour alimenter vos lecteurs de
proximité, veillez bien à raccorder les
différentes masses avec celle de la centrale.
+12V/200mA max
0V
DATA1 / CLOCK
DATA0 / DATA
Led
WIEGAND :
o Proximity readers
(PRASTEL, HID, STID, INDALA, …)
o Keyboards (PRASTEL, XPR, …)
o Biometric readers (PRASTEL, …)
o Radio receivers (PRASTEL, …)
o DALLAS (via interface)
CLOCK & DATA :
o Magnetic Stripe Readers
o Bar code readers
o Proximity readers
o Radio receivers
MT50000/2 V1.0 ENGLISH
p.6/14
PRASTEL France SARL
ZI Athélia II, 225 Impasse du Serpolet, 13704 LA CIOTAT Cedex
Tél : 04.42.98.06.06 Fax : 04.42.04.53.51 infos@prastelfrance.fr
CONNECTING THE MT50000-EXT4 AND MT15000-EXT-IO MODULES
Information :
2 wires (2 pairs recommended)
Max Distance : 750m
Cable type : 0,6mm (SYT conseillé)
Warning : Do not wire the wires near other cables carrying high voltages or currents, especially
220V cables or more. Be sure to use the same pair for wires A and B.
Up to 10
modules per
MT50000/2
RS485
MT50000/2
MT50000/EXT4
MT15000/EXT-IO
MT50000/2 V1.0 ENGLISH
p.7/14
PRASTEL France SARL
ZI Athélia II, 225 Impasse du Serpolet, 13704 LA CIOTAT Cedex
Tél : 04.42.98.06.06 Fax : 04.42.04.53.51 infos@prastelfrance.fr
CONNECTING A CURRENT BREAKAGE AND AN ELECTROMAGNETIC
SUCTION OPERATING BY LACK OF CURRENT
Warning : In order to avoid any random malfunctions which would disturb the good use of the sys-
tem due to return currents, it is imperative to use and connect the non-return diodes delivered with
the control unit according to the wiring diagram above..
Even when using an additional back-up power supply for separate locking from that of the central
unit, it is mandatory to follow the same wiring diagram described above..
Anti-return diode
MT50000/2 V1.0 ENGLISH
p.8/14
PRASTEL France SARL
ZI Athélia II, 225 Impasse du Serpolet, 13704 LA CIOTAT Cedex
Tél : 04.42.98.06.06 Fax : 04.42.04.53.51 infos@prastelfrance.fr
CONNECTING A STANDARD SPACER WITH VOLTAGE EMISSION
Warning : In order to avoid any random malfunctions which would disturb the good use of the sys-
tem due to return currents, it is imperative to use and connect the non-return diodes delivered with
the control unit according to the wiring diagram above..
Even when using an additional emergency power supply for the separate locking of the central
unit, it is mandatory to follow the wiring diagram described above..
Power supply
+12V 0V
Anti-return diode
MT50000/2 V1.0 ENGLISH
p.9/14
PRASTEL France SARL
ZI Athélia II, 225 Impasse du Serpolet, 13704 LA CIOTAT Cedex
Tél : 04.42.98.06.06 Fax : 04.42.04.53.51 infos@prastelfrance.fr
CONNECTING A PUSH BUTTON AND MICRO SWITCH BOX 220V
MT50000/2 V1.0 ENGLISH
p.10/14
PRASTEL France SARL
ZI Athélia II, 225 Impasse du Serpolet, 13704 LA CIOTAT Cedex
Tél : 04.42.98.06.06 Fax : 04.42.04.53.51 infos@prastelfrance.fr
CONNECTING THE MT50000/2 CONTROL UNIT TO THE ETHERNET
NETWORK
Each MT50000 / 2 control unit has an IP address. This address is written on a label stuck on the
box of the central.
To configure a different IP address, you can use the "Automatic detection" menu of
SWAMIGO3. To do this, proceed as follows:
Configure your PC as a fixed IP address close to the address range of the control panel
192.168.2.xxx
After creating your installation, at first launch, SWAMIGO3 proposes to create a new central
Click on the "Search" button
The list of detected plants appears
Double click on the control panel you wish to add
Check in the state of the equipment that your plant is well connected.
Crossover cable
Straight cable
Straight cable
MT50000/2 V1.0 ENGLISH
p.11/14
PRASTEL France SARL
ZI Athélia II, 225 Impasse du Serpolet, 13704 LA CIOTAT Cedex
Tél : 04.42.98.06.06 Fax : 04.42.04.53.51 infos@prastelfrance.fr
MT50000/2 V1.0 ENGLISH
p.12/14
PRASTEL France SARL
ZI Athélia II, 225 Impasse du Serpolet, 13704 LA CIOTAT Cedex
Tél : 04.42.98.06.06 Fax : 04.42.04.53.51 infos@prastelfrance.fr
INSTALLATION OF SWAMIGO3 DONGLE
To use your SWAMIGO3 software, you will need, in some cases (see following table), to install a
dongle on your MT50000 / 2 control panel.
Using the dongle
Number of readers on the installation
Software
Dongle
Until 4 readers
SWAMIGO3 LIGHT
No dongle required
Until 10 readers
SWAMIGO3-10
Dongle needed
Until 40 readers
SWAMIGO3-40
Dongle needed
Until 80 readers
SWAMIGO3-80
Dongle needed
Until 140 readers
SWAMIGO3-140
Dongle needed
Until 840 readers
SWAMIGO3-840
Dongle needed
Dongle Installation: Without power supply, install the Dongle as follows:
To verify the correct operation, SWAMIGO3 tells you which version is in use at the bottom of the
main window. Your control panel must be rated for the dongle to be detected.
If you do not have the correct dongle according to your type of installation, your plants will be dis-
played "nominal" in the state of the equipment but no update or collection of events will be made.
MT50000/2 V1.0 ENGLISH
p.13/14
PRASTEL France SARL
ZI Athélia II, 225 Impasse du Serpolet, 13704 LA CIOTAT Cedex
Tél : 04.42.98.06.06 Fax : 04.42.04.53.51 infos@prastelfrance.fr
FUNCTIONS OF CONNECTION TERMINALS
MT50000/2 V1.0 ENGLISH
p.14/14
PRASTEL France SARL
ZI Athélia II, 225 Impasse du Serpolet, 13704 LA CIOTAT Cedex
Tél : 04.42.98.06.06 Fax : 04.42.04.53.51 infos@prastelfrance.fr
USE OF RESET BUTTONS
Use this switch to reset the factory network settings (IP
address: 192.168.2.150, mask 255.255.255.0).
Turn off the power.
Hold down the switch while turning on the power
- To configure the product in fixed IP, release the switch
at the 1st RS485 blue led flashing (approx 5 seconds).
- To activate the product in DHCP mode, wait for the
RS485 blue led to become fixed (approximately 10 sec-
onds).
Use this switch to clear all the memory of the central
Turn off the power.
Hold down the switch while turning on the power
Wait for the RS485 blue led to become steady (about 10
seconds) while holding down the switch
Release the switch
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14