Thank you very much for purchasing our air conditioner.
Please read this owner's manual carefully before using
your air conditioner.
MODE
FAN SPEED
M
AUTO
COOL
DRY
HEAT
FAN
ILLUSTRATION
Model
Lowest Voltage of
CPU Emitting Signal
Rated Voltage
8m
3.0V(Dry batteries R03/LR03 2)
2.4V
Remot e Con trolle r Spe cificat ions
1. Operating Mode: AUTO, COOL, DRY, HEAT(cooling & heating models only),
and FAN.
2. Timer Setting Function in 24 hours.
O O O O
3. Indoor Setting Temperature Range : 6 2 F~86 F(17 C~30 C).
4. Full function of LCD (Liquid Crystal Display).
Environment
Signal Receiving
Range
Perfor manc e Featur e
33
MODE
FAN SPEED
M
AUTO
COOL
DRY
HEAT
FAN
Sliding door
(closed)
RG05F2/BGEU1
O O O O
23 F~140 F(-5 C~60 C)
Funct ion bu ttons
1
2
Each time the button is pressed, the operation
mode is selected in a sequence of following:
3
MODE Button
44
3
4
ON/OFF Button
Operation starts when this button is pressed
and stops when this button is pressed again.
NOTE: Please do not select HEAT mode if the
machine you purchased is cooling only type. Heat
mode is not supported by the cooling only
appliance.
AUTO
COOL
DRY
HEAT FAN
SLEEP Button
NOTE: While the unit is running under SLEEP
mode, it would be cancelled if MODE, FAN
SPEED or ON/OFF button is pressed.
Active/Disable sleep function. It can maintain
the most comfortable temperature and save
energy. This function is available on COOL,
HEAT or AUTO mode only .
SWING V Button
Used to stop or start horizontal louver move-
ment and set the desired up/down air flow
direction. Push once, the louver changes 6
degree in angle. Keep pushing more than 2
seconds, the louver will swing up and down
automatically.
MODE
FAN SPEED
SWING V SLEEP
TIMER ON
TIMER OFF
CLOCK
RESET LOCK
M
AUTO
COOL
DRY
HEAT
FAN
4
5
7
8
9
10
11
12
13
14
15
2
1
TURBO
LED
Sliding door
(opened)
SWING H
16
5
SWING H Button
Used to stop or start vertical louver movement
and set the desired left/right air flow direction.
The vertical louver changes 6 degree in angle
for each press.If keep pushing more than 2
seconds,the vertical louver swing feature is
activated.(Not applicable to all the units,please
refer to the OWNER S MANUAL for details).
SELF CLEAN
6
I FEEL
I FEEL /SELF CLEAN Fun ction
Press this button less than 2 seconds will
initiate I FEEL function. And if keep pressing
this button more than 2 seconds, the
SELF CLEAN function is initiated.
6
Funct ion bu ttons (cont inued )
55
Used to select the fan speed in four steps:
AUTO LOW MED HIGH
FAN SPEED Button
11
DOWN Button
Push this button to decrease setting temperature
or to decrease Hour during Clock time setting.
NOTE: Press and hold UP and DOWN buttons
together for 3 seconds will alternate the temper-
O O
ature display between the C & F scale.
9
10
UP Button
Push this button to increase setting temperature
or to increase Hour during Clock time setting.
8
LOCK Button
Press this recessed button to lock all current
settings, and the remote controller will not
accept any operation except that of the LOCK.
Use the LOCK mode when you want to prevent
settings from being changed accidentally.
Press the LOCK button again to cancel the
LOCK function. A lock symbol will appear on
the remote controller display when the lock
function is activated.
7
RESET Button
Once the recessed RESET button is pressed,
all of the current settings will be cancelled
and the controller will return to the initial settings.
3
MODE
FAN SPEED
SWING V SLEEP
TIMER ON
TIMER OFF
CLOCK
RESET LOCK
M
AUTO
COOL
DRY
HEAT
FAN
4
5
7
8
9
10
11
12
13
14
15
2
1
TURBO
LED
SWING H
16
SELF CLEAN
6
I FEEL
When the I FEEL function is activated, the
remote display is actual temperature at its
location. The remote control will send this
signal to the air conditioner every 3 minutes
interval until press the I FEEL button again.
This indicator light remains on.
The I FEEL function is not available under
DRY and FAN mode.
Switch the operation mode or turn off the unit
will cancel the I FEEL function automatically.
Under SELF CLEAN mode, the air conditioner
will automatically clean and dry the Evaporator
and keep it as fresh for the next operation.
66
12
13
TURBO
Active/Disable Turbo function. Turbo function
enables the unit to reach the preset temperature
in the shortest time. When press this button
on heating mode(applicable to the unit adopts
PTC only), the PTC will be energized and bring
fast heating operation.
LED Button
Disable/Active indoor screen Display.
13
TIMER ON Button
Press this button to activate the Auto-on time
setting. Each press will increase the time setting
in 30 minutes increments, up to 10 hours, then at
1 hour increments up to 24 hours. To cancel the
Auto-on time setting, just press the button until
the time setting is 0.0.
TIMER OFF Button
15
Press this button to activate the Auto-off time
setting. Each press will increase the time setting
in 30 minutes increments, up to 10 hours, then at
1 hour increments up to 24 hours. To cancel the
Auto-off time setting, just press the button until
the time setting is 0.0.
CLOCK Button
Used to set the remote clock.
16
NOTE:
Buttons design might be slightly different
from the actual one depending on individual
models.
All the functions described above are
accomplished by the indoor unit, if the
indoor unit has no this feature, there is no
corresponding operation happened when
press the relative button on the remote
controller.
Please do not select HEAT mode if the
machine you purchased is cooling only
type. Heat mode is not supported by the
coolingonly appliance.
3
MODE
FAN SPEED
SWING V SLEEP
TIMER ON
TIMER OFF
CLOCK
RESET LOCK
M
AUTO
COOL
DRY
HEAT
FAN
4
5
7
8
9
10
11
12
13
14
15
2
1
TURBO
LED
SWING H
16
SELF CLEAN
6
I FEEL
14
77
Indica tors on LC D
Transmission Indicator
Temp. display
Time display
Fan speed display
Sleep Display
Mode display
ON/OFF display
This transmission indicator lights when remote
controller transmits signals to the indoor unit.
Displays the current operation mode. Including
AUTO( ), COOL( ), DRY( ), HEAT( )
(Not applicable to cooling only models), FAN( )
and back to AUTO( ).
O O O
Displays the temperature setting(62F ~86F /17C ~
O
30C ). When you set the operating mode to FAN, no
temperature setting is displayed.
Displayed by pressing the ON/OFF button.
Press the ON/OFF button again to remove.
Indicate Timer on/off time(0~24 hours) or clock
time. The clock time is indicated only when no AUTO-
ON/OFF timer is set. When AUTO-TIMER feature is
operating, it displays the AUTO-ON/OFF time. To
check the current time, press the CLOCK button, and
the time will display.
Displays the selected fan speed, AUTO( ) and three
fan speed levels " " (LOW) " " (MED)
" " (HIGH) can be indicated. The fan speed
is auto controlled under AUTO or DRY mode.
Displayed under sleeping operation.
Press the SLEEP button again to remove.
AUTO
Lock Display
Displayed when LOCK mode is activated.
AUTO
COOL
DRY
HEAT
FAN
TEMP.
SET
CLOCK
TIMER
HOUR
ON OFF
FF
Note:
All displays on the remote controller are
shown for illustration purposes only.
I FEEL Display
Displayed when I FEEL function is activated.
88
1
Static electricity or other factors (Voltage transients) can
cause the remote controller clock to initialize. If your
remote controller is initialized (the time of "12:00"
flashing), readjust the clock before starting the unit.
CAUTION
!
How to use t he bu ttons
2
Before you start operating the air conditioner, set
the clock of the remote controller using the proce-
dures given in this section. The clock panel on the
remote controller will display the time regardless of
whether the air conditioner is in use or not.
After batteries are inserted in the remote controller,
the clock panel will display "12:00" and begin to flash.
1. UP/DOWN button
Press these buttons to set time.
Forward.
Backward.
Each time you press the button, the time moves
forward or backward by one minute depending
on which side you press. The time alters as quickly
as you push the button.
Keep pressing the button without releasing, the
time moves forward or backward by 10 minutes
depending on which side you press.
Initial Setting the Clock
.
.
When the right time is achieved, press the CLOCK
button or release the or and wait for 5
seconds, the clock time stops flashing and the
clock starts operating.
Press the CLOCK button on the remote controller,
the time of the clock display will start to flash. To
set the new time, follow 1 and 2 of "Initial Setting
of the Clock".
Note: The time of the CLOCK must be set before
the AUTO-TIMER feature will operate.
* Clock accuracy is within 15 seconds per day.
2.
3.Readjusting the Clock
.
CLOCK button
MODE
FAN SPEED
SWING V SLEEP
TIMER ON
TIMER OFF
CLOCK
RESET LOCK
AUTO
COOL
DRY
HEAT
FAN
TEMP.
SET
CLOCK
TIMER
HOU R
ON OFF
M
SWING H
SELF CLEAN
TURBO
LED
I FEEL
99
Coolin g /Hea ting/Fa n ope ration
Ensure the unit is plugged in and power is
available.
1. Press the MODE button to select COOL, HEAT,
(cooling & heating models only) or FAN mode.
2. Press the UP/DOWN buttons to set the
desired temperature.
3. Press the FAN SPEEDbutton to select the
fan speed in four steps- Auto, Low, Med,or
High.
4. Press the ON/OFF button to start the air
conditioner.
The temperature can
O O O
be set within a range of 62F~86 F in 1F
increments.
In the FAN mode, the setting temperature is not
displayed in the remote controller and you are not able
to control the room temperature either. In this case,
only step 1, 3 and 4 may be performed.
NOTE
Auto o perat ion
Ensure the unit is plugged in and power is
available. The OPERATION indicator on the
display panel of the indoor unit starts flashing.
1. Press the MODE button to select Auto.
2. Press the UP/DOWN button to set the
desired temperature. The temperature can
O O O
be set within a range of 62F~86 F in 1F
increments.
3. Press the ON/OFFbutton to start the air
conditioner.
1
1. In the Auto mode, the air conditioner can logically
choose the mode of Cooling, Fan, and Heating
by sensing the difference between the actual
ambient room temperature and the setting
temperature on the remote controller.
2. In the Auto mode, you can not switch the fan speed.
It has already been automatically controlled.
3. If the Auto mode is not comfortable for you , the
desired mode can be selected manually.
NOTE
3
2
3
2
MODE
FAN SPEED
M
AUTO
COOL
DRY
HEAT
FAN
TEMP.
SET
CLOCK
HOUR
1
4
AUTO
COOL
DRY
HEAT
FAN
TEMP.
SET
CLOCK
HOU R
MODE
FAN SPEED
M
1010
Dehum idifyin g ope ration
Ensure the unit is plugged in and power is
available. The OPERATION indicator on the
display panel of the indoor unit starts flashing.
1. Press the MODE button to select DRY mode.
2. Press the UP/DOWN buttons to set the
desired temperature.
3. Press the ON/OFF button to start the air
conditioner.
The temperature can
O O O
be set within a range of 62F~86 F in 1F
increments.
In the Dehumidifying mode, you can not switch the
fan speed. It has already been automatically controlled.
NOTE
Adjus ting a ir flow dire ction
Use the SWING V button to adjust the desired
airflow direction.
When push the SWING V button, the horizontal
louver changes 6 degree in angle for each push.
Keep pushing more than 2 seconds, the louver
will swing automatically and give UP and
DOWN air flow.
NOTE: When the horizontal louver swing
or move to a position which would affect
the cooling or heating effect of the air
conditioner, it would automatically change
the swing/moving direction.
1
3
2
MODE
FAN SPEED
M
AUTO
COOL
DRY
HEAT
FAN
TEMP.
SET
CLOCK
HOUR
1111
1
2
Timer oper ation
press the TIMER ON button can set the auto-on
time of the unit. And press the TIMER OFF button
can set the auto-off time of the unit.
1. Press the TIMER ON button. The remote
controller shows TIMER ON, the last Auto-on
setting time and the signal "HOUR" will be shown
on the LCD display area. Now it is ready to reset
the Auto-on time to START the operation.
2. Push the TIMER ON button again to set desired
Auto-on time. Each time you press the button,
the time increases in 30 minutes increments, up
to 10 hours, then at 1 hour increments up to 24
hours.
3. After setting the TIMER ON ,there will be a one-
half second delay before the remote controller
transmits the signal to the air conditioner. Then,
after approximately another 2 seconds, the
signal "HOUR" will disappear and the set temper-
ature will re-appear on the LCD display window.
To set the Auto-on time.
To set the Auto-off time.
1. Press the TIMER OFF button. The remote
controller shows TIMER OFF, the last Auto-off
setting time and the signal "HOUR" will be shown
on the LCD display area. Now it is ready to
reset the Auto-off time to START the operation.
2. Push the TIMER OFF button again to set desired
Auto-off time. Each time you press the button,
the time increases in 30 minutes increments, up
to 10 hours, then at 1 hour increments up to 24
hours.
3. After setting the TIMER OFF ,there will be a one-
half second delay before the remote controller
transmits the signal to the air conditioner. Then,
after approximately another 2 seconds, the
signal "HOUR" will disappear and the set temper-
ature will re-appear on the LCD display window.
MODE
FAN SPEED
SWING V SLEEP
TIMER ON
TIMER OFF
CLOCK
RESET LOCK
AUTO
COOL
DRY
HEAT
FAN
TEMP.
SET
CLOCK
TIMER
HOU R
ON OFF
M
SWING H
SELF CLEAN
TURBO
LED
I FEEL
1212
The effective operation time set by the remote controller for the timer
function is limited to the following settings: 0.5, 1.0, 1.5, 2.0, 2.5, 3.0,
3.5, 4.0, 4.5, 5.0, 5.5, 6.0, 6.5, 7.0, 7.5, 8.0, 8.5, 9.0, 9.5, 10, 11, 12, 13,
14, 15,16,17, 18, 19, 20, 21, 22, 23 and 24.
IMPORTANT
Exam ple of Time r sett ing
Start
Off
6 hours later
(Auto-on Operation)
The TIMER ON feature is useful when you want
the unit to turn on automatically before say when
you return home. The air conditioner will automa-
tically start operating at the set time.
To start the air conditioner in 6 hours.
1. Press the TIMER ON button, the last setting of
starting operation time and the signal "HOUR" will
show on the display area.
2. Press the TIMER ON button to display "6.0" on
the TIMER ON display of the remote controller.
3. Wait for 3 seconds and the TIMER ON indicator
stops flashing and this function is activated. The
digital display area will show the tempera ture
again.
TIMER ON
Example:
Set
TIMER
HOUR
ON
1313
Stop
On
Set 10 hours later
(Auto-off Operation)
The TIMER OFF feature is useful when you want
the unit to turn off automatically after you go to bed.
The air conditioner will stop automatically at the set
time.
To stop the air conditioner in 10 hours.
1. Press the TIMER OFF button, the last setting of
stopping operation time and the signal "HOUR" will
show on the display area.
2. Press the TIMER OFF button to display "10" on
the TIMER OFF display of the remote controller.
3. Wait for 3 seconds and the TIMER OFF indicator
stops flashing and this function is activated. The
digital display area will show the temperature
again.
TIMER OFF
Example:
On
Stop
2 hours later
after setting
Set
To stop the air conditioner 2 hours after setting
and start it again 10 hours after setting.
1. Press the TIMER OFF button.
2. Press the TIMER OFF button again to
display 2.0 HOUR on the TIMER OFF display.
3. Press the TIMER ON button.
4. Press the TIMER ON button again to
display 10 HOUR on the TIMER ON display .
5. Wait for the remote control to display
the setting temperature.
TIMER OFF TIMER ON
(On Stop Start operation)
This feature is useful when you want to stop the air
conditioner after you go to bed, and start it again in
the morning when you wake up or when you return
home.
Example:
COMBINED TIMER
(Setting both ON and OFF timers simultaneously)
Start
10 hours later
after setting
TIMER
HOUR
OFF
TIMER
HOUR
ON OFF
1414
Example:
TIMER ON TIMER OFF
(Off Start Stop operation)
This feature is useful when you want to start
the air conditioner before you wake up and
stop it after you leave the house.
To start the air conditioner 2 hours after
setting, and stop it 5 hours after setting.
1. Press the TIMER ON button.
2. Press the TIMER ON button again to
display 2.0 HOUR on the TIMER ON display.
3. Press the TIMER OFF button.
4. Press the TIMER OFF button again to
display 5.0 HOUR on the TIMER OFF display .
5. Wait for the remote control to display
the setting temperature.
Off
Stop
Start
2 hours later
after setting
5 hours later
after setting
Set
TIMER
HOUR
ON OFF
The design and specifications are subject to change without prior notice
for product improvement. Consult with the sales agency or manufacturer
for details.
Tel: (305)594-4972 Fax (305) 499 4378
www.klimaire.com [email protected]
2190 NW 89 Place, Doral, FL 33172 - USA
The Klimaire logo is a registered Trademark of Klimaire Products inc.
Copyright 2010 Klimaire Products inc.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15

Klimaire KTIR24H2 User manual

Category
Split-system air conditioners
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI