Part 1 General Information .................................................................................................... 1
Part 2 Indoor Units ................................................................................................................. 5
Part 3 Outdoor Units............................................................................................................. 23
Part 4 Installation.................................................................................................................. 29
Part 5 Electrical Control System......................................................................................... 63
The specifications, designs, and information in this book are subject to change without notice for
product improvement.
2
General Information
Part 1
General Information
1. Model Lists................................................................................................3
1.1 Indoor Units
1.2 Outdoor Units
2. Nomenclature ......................... .................................................................4
3
1.1 Indoor Units
R410A ( ) Capacity x 1000 Btu/h
Type Function 12 18 24
4-way cassette Cooling and heating
Duct Cooling and heating
Ceiling-floor Cooling and heating
Console Cooling and heating
1.2 Outdoor Units
Universal Outdoor unit Model Compressor type Matched indoor units
KSIL012-H219-0
Rotary TOSHIBA
KDIM012-H2
KFIM012-H2
KTIM012-H2
KUIM012-H2
Rotary TOSHIBA
Rotary TOSHIBA
4
Compressor Brand
KTIM
KDIM
KUIM
KFIM
KSIL018-H219-0
KSIL024-H219-0
KDIM018-H2
KTIM018-H2
KUIM018-H2
KDIM024-H2
KTIM024-H2
KUIM024-H2
Indoor Units
2. Nomenclature
2.1 Indoor Unit
3.2 Outdoor Unit
5
Brand
K: Klimaire
Model
D: Ceiling recessed
F: Console
T: Ceiling cassette
U: Floor-ceiling
Unit Type
I: Inverter
Product Series
M
Nominal Capacity (kBtu/h)
Operational Information
C: Cooling only
H: Heat pump
Power Supply
1: 115 V / 1 ph /60 Hz
2: 208-230 V / 1 ph / 60 Hz
K T I M
012
-
H 2
K S I M 024-H 2 19 - O C
Brand
K: Klimaire
Model
S: System
Unit Type
I: Inverter
Product Series
Nominal Capacity (kBtu/h)
Operational Information
C: Cooling only
H: Heat pump
Power Supply
1: 115 V / 1 ph / 60 Hz
2: 208-230 V / 1 ph / 60 Hz
Efficiency SEER
Usage
O: Outdoor
Application
C: Commercial
Indoor Units
Part 2
Indoor Units
4-way Cassette Type........................................................7
Duct Type........................................................................10
Ceiling & Floor Type .......................................................16
Console Type..................................................................21
6
4-way Cassette Type
4-way Cassette Type
1. Service Space ..................................................... 7
2. Wiring Diagrams ................................................. 8
3. Field Wiring .......................................................... 9
7
1. Service Space
8
>39"
>39"
>39"
>39"
>90"
A>11"
0.39"- 0.47"
6.9"
1.3"
4-way Cassette Type
Wiring Diagrams
2. Wiring Diagrams
KTIM012-H2 KTIM018-H2
KTIM024-H2
9
Field Wiring
3. Field Wiring
10
KTIM012-H2 KTIM018-H2
KTIM024-H2
Duct Type LISAS-A-1211
Duct Type
1. Service Space........................................................11
2. Wiring Diagrams .................................................. 1 2
3. Static Pressure......................................................14
4. Field Wiring ......................................................... 15
11
Service Space
3. Service Space
Ensure enough space required for installation and m aintenance.
All the indoor units reserve the hole to joint the fresh air pipe. The hole size as following:
12
7.8" or more 11.8" or more
23.6" x 23.6"
3.5"
3.1"
3.1"
4.9"
6.2"
Wiring Diagrams
2. Wiring Diagrams
13
KDIM012-H2 KDIM018-H2
Wiring Diagrams
14
KDIM024-H2
Static Pressure
3. Static Pressure
12,000 Btu/h 18,000 Btu/h
Super high speed
0
900
600
500
Mid speed
High speed
External static pressure (Pa)
3
Air volume(m /h)
Pa
90
80
70
60
50
40
30
20
10
Low speed
300 400
700
800
Super high speed
500400300
200
Low speed
10
20
30
40
50
60
70
80
90
Pa
600 700 800 900 1000 1100
Air volume(m /h)
3
External static pressure (Pa)
High speed
Mid speed
1200
24,000 Btu/h
Super high speed
14001300
Low speed
10
20
30
40
50
60
70
80
90
Pa
800 900 1000 1100
Air volume(m /h)
3
External static pressure (Pa)
High speed
Mid speed
1200
1500
700
15
Field Wiring
4. Field Wiring
16
KDIM012-H2 KDIM018-H2
KDIM024-H2
Field Wiring
Ceiling & Floor Type
1. Service Space............................................................ 17
2. Wiring Diagrams ........................................................ 18
3. Field Wiring ................................................................ 20
17
Service Space
1. Service Space
12K,18K
C
24K~48K
18
1.37"
1.37"
1.37"
40"
>1.37"
>1.37"
>1.37"
40"
Wiring Diagrams
2. Wiring Diagrams
19
KUIM012-H2 KUIM018-H2
Wiring Diagrams
20
KUIM024-H2
/