WARNING - RISK OF SHOCK
DISCONNECT POWER BEFORE INSTALLATION
T: 508 678-5411 | F: 508 678-5408 www.atlantic-lighting.com
Commercial Series LED
4˝ Trimless
Installation Instructions
Page 2
The perforated portion of the Mud-Ring to be covered
during the “mud” process to the top of the Mud Lip and
feathered outward for a smooth ceiling.
After all sanding and painting is complete, remove the
Paint Shield and clean the inside edge of the Mud Lip
prior to installation of the reflector.
5
6
Refer to step 4 of the complete installation instructions
for the LED Commercial Series, 4” & 5” for final
installation of the reflector and other important
information and safety instructions.
7
THIRD ANGLE PROJECTION
A
Mud Lip
Reflector Side
D
C
B
A
A
B
C
D
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
E
F
E
F
E
PLASTER RING section view
REV
SHEET 1 OF 1
1/29/2020
C. PACHECO
J. ESTRELA
G. ESTRELA
GIL MILLER
UNLESS OTHERWISE SPECIFIED
ALL DIMENSIONS ARE INCHES
SCALE: 2:1
WEIGHT:
REV
DWG. NO.
E
SIZE
TITLE:
NAME
DATE
COMMENTS:
Q.A.
MFG APPR.
ENG APPR.
CHECKED
DRAWN
FINISH
MATERIAL
DIMENSIONAL TOLERANCES
.0
.12
.00
.03
.000
.005
.0000
.0002
ANGLES
0" 30' 0"
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
ATLANTIC LIGHTING. ANY
REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OF
ATLANTIC LIGHTING AND GIL MILLER IS
PROHIBITED.
DO NOT SCALE DRAWING
231 COMMERCE DRIVE
FALL RIVER, MA 02720
PHONE: 508-678-5411
FAX: 508-678-5408
A
Mud Lip
Reflector Side
D
C
B
A
A
B
C
D
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
E
F
E
F
E
PLASTER RING section view
REV
SHEET 1 OF 1
1/29/2020
C. PACHECO
J. ESTRELA
G. ESTRELA
GIL MILLER
UNLESS OTHERWISE SPECIFIED
ALL DIMENSIONS ARE INCHES
SCALE: 2:1
WEIGHT:
REV
DWG. NO.
E
SIZE
TITLE:
NAME
DATE
COMMENTS:
Q.A.
MFG APPR.
ENG APPR.
CHECKED
DRAWN
FINISH
MATERIAL
DIMENSIONAL TOLERANCES
.0
.12
.00
.03
.000
.005
.0000
.0002
ANGLES
0" 30' 0"
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
ATLANTIC LIGHTING. ANY
REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OF
ATLANTIC LIGHTING AND GIL MILLER IS
PROHIBITED.
DO NOT SCALE DRAWING
231 COMMERCE DRIVE
FALL RIVER, MA 02720
PHONE: 508-678-5411
FAX: 508-678-5408
Mud Lip
Reflector
Side
THIRD ANGLE PROJECTION
Mud Ring
Alignment Tube
Paint Shield
Screws
10-32 x 1-
1
4
" Long
Flat Head Screws (x4)
D
C
B
A
A
B
C
D
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
E
F
E
F
E
Commercial Trimless parts
REV
SHEET 1 OF 1
3/10/2020
C. PACHECO
J. ESTRELA
G. ESTRELA
GIL MILLER
UNLESS OTHERWISE SPECIFIED
ALL DIMENSIONS ARE INCHES
SCALE: 2:1
WEIGHT:
REV
DWG. NO.
E
SIZE
TITLE:
NAME
DATE
COMMENTS:
Q.A.
MFG APPR.
ENG APPR.
CHECKED
DRAWN
FINISH
MATERIAL
DIMENSIONAL TOLERANCES
.0
.12
.00
.03
.000
.005
.0000
.0002
ANGLES
0" 30' 0"
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
ATLANTIC LIGHTING. ANY
REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OF
ATLANTIC LIGHTING AND GIL MILLER IS
PROHIBITED.
DO NOT SCALE DRAWING
231 COMMERCE DRIVE
FALL RIVER, MA 02720
PHONE: 508-678-5411
FAX: 508-678-5408
WARNING
Risk of Electrical Shock
Disconnect power from circuit breaker or
fuse before installing or servicing any light fixture.
T: 508 678-5411 | F: 508 678-5408 www.atlantic-lighting.com
Page 1
Fig. 2
Fig. 1
120 VOLT
The standard hanger bars supplied with the housing has a notch cut out of the bottom so it can sit on top of the T-grid then simply attach
a wire with the holes provided as shown in Fig. 4.
The other option is using a set of 517 Caddy bars or equal
which are designed to snap onto the top of the T-bar for quick
installation as shown in Fig. 5.
Fig. 4
T-Grid or Drop Ceiling Installation
Wire (by others) is not necessary and is optional (check your local codes).
LED Commercial Series,
4" & 5"
Installation Instructions
Fig. 3
1. As seen in Fig. 1 and 2, extend the hanger bars until they meet the ceiling joist. Frame to be install flush to the top side of ceiling
material. Drive in the self fastener at the end of the hanger bar. Then for a more permanent fastener install a screw or a nail using
the holes provided. For installation of this fixture in a grid or drop ceiling refer to Figures 3 and 4 below.
Frame must be rigid and not allow the fixture to lift while reflector is being installed.
2. Remove the junction box cover and wire in fixture per your local codes. When wiring is complete make sure to attach the junction
box cover securely with the attached clip.
3. LED module should be protected from dust or paint during the ceiling installation process.
4. After the ceiling is installed, the reflector is to be secured to the LED module and inserted into the ceiling opening. Remove any
protective covering from the LED module and position the module on top of the reflector clips with reflector screws accesible.
(as shown in Fig1.A ) Align the key-slots in the reflector over the two reflector screws on the LED module and tighten the screws to
secure. Push reflector up into the ceiling opening untill flange is flush against the ceiling.
5. IMPORTANT: THIS FIXTURE MAY BE EQUIPPED WITH A VOLTAGE SPECIFIC THERMAL DEVICE AND MAY ONLY BE
WIRED ACCORDING TO THE VOLTAGE THAT WAS ORDERED. DO NOT CHANGE THE VOLTAGE SPECIFIED.
REFERENCE EXAMPLE: Model No. COM4-SYL30-35K-1 (or) Model No. COM4-SYL30-35K-2
6. Dimming: Reference our website
atlantic-lighting.com/main/support
for compatible dimmers for the standard
0-10VDC driver or optional drivers.
Fig.1.A
277 VOLT
REFLECTOR SCREWS
01/31/20
LED_Install_Sheet_4_Comm_SYL_013120.pdf