This manual is also suitable for

AssuredSAN 2333
Setup Guide
P/N 83-00006619-10-01
Revision A
February 2013
Copyright © 2013 Dot Hill Systems Corp. All rights reserved. Dot Hill Systems Corp., Dot Hill, the Dot Hill logo, AssuredSAN, AssuredSnap,
AssuredCopy, AssuredRemote, R/Evolution, and the R/Evolution logo are trademarks of Dot Hill Systems Corp. All other trademarks and registered
trademarks are proprietary to their respective owners.
The material in this document is for information only and is subject to change without notice. While reasonable efforts have been made in the
preparation of this document to assure its accuracy, changes in the product design can be made without reservation and without notification to its
users.
AssuredSAN 2333 Setup Guide 3
About this guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Intended audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Prerequisites. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Related documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Document conventions and symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
1 Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
12-drive enclosure front panel components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Controller enclosure — rear panel layout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2333 controller module — rear panel components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3130 drive enclosure rear panel components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Component installation and replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Cache . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
CompactFlash . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Super-capacitor pack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
2 Installing the enclosures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Installation checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Network Equipment-Building System (NEBS) Level 3 compliance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Generic Requirements (GRs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Exceptions to GRs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Product documentation requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Connecting the controller enclosure and drive enclosures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Cable requirements for drive enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Summary of drive enclosure cabling illustrations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Testing enclosure connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Powering on/powering off. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Power Cords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
AC PSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
3 Connecting hosts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Host system requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Cabling considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Connecting the enclosure to hosts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
iSCSI host ports (1Gb) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Connecting direct attach configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Single-controller configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Dual-controller configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Connecting switch attach configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Connecting a management host on the network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Updating firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Obtaining IP values. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Setting network port IP addresses using DHCP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Setting network port IP addresses using the CLI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
4 Basic operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Accessing RAIDar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Configuring and provisioning the storage system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
5 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
USB CLI port connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Fault isolation methodology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Basic steps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Options available for performing basic steps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Use RAIDar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Contents
4Contents
Use the CLI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Monitor event notification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
View the enclosure LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Performing basic steps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Gather fault information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Determine where the fault is occurring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Review the event logs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Isolate the fault . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
If the enclosure does not initialize . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Correcting enclosure IDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Stopping I/O. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Diagnostic steps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Is the enclosure front panel Fault/Service Required LED amber?. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Is the controller back panel FRU OK LED off? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Is the controller back panel Fault/Service Required LED amber? . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Are both disk drive module LEDs off? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Is the disk drive module Fault LED amber?. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Is a connected host port’s Host Link Status LED off? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Is a connected port’s Expansion Port Status LED off?. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Is a connected port’s Network Port link status LED off? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Is the power supply’s Input Power Source LED off? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Is the Voltage/Fan Fault/Service Required LED amber? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Isolating a host-side connection fault . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Isolating a controller module expansion port connection fault. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Resolving voltage and temperature warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Sensor locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Power supply sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Cooling fan sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Temperature sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Power supply module voltage sensors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
A LED descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
12-drive enclosure front panel LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Disk drive LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Controller enclosure — rear panel layout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
2333 controller module — rear panel LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Cache Status LED details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Power supply LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
3130 drive enclosure rear panel LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
B Environmental requirements and specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Safety requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Site requirements and guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Site wiring and AC power requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Weight and placement guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Electrical guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Ventilation requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Cabling requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Management host requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Physical requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Environmental requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Electrical requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Site wiring and power requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Power cable requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
C Electrostatic discharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Preventing electrostatic discharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Grounding methods to prevent electrostatic discharge. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
AssuredSAN 2333 Setup Guide 5
D USB device connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Rear panel USB ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
USB CLI port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Emulated serial port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Supported host applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Command-line Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Device driver/special operation mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Microsoft Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Obtaining the software download. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Linux . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Setting parameters for the device driver. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
6Contents
AssuredSAN 2333 Setup Guide 7
Figures
1 CompactFlash . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2 Cabling connections between a controller enclosure and one drive enclosure . . . . . . . . . . . . . . . . . . 20
3 Fault-tolerant cabling between a dual-controller enclosure and four drive enclosures. . . . . . . . . . . . . . 21
4 Reverse cabling between a dual-controller enclosure and seven drive enclosures . . . . . . . . . . . . . . . . 22
5 AC PSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
6 AC power cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
7 Connecting hosts — one server/one HBA/dual path . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
8 Connecting hosts — two servers/one HBA per server/dual path . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
9 Connecting hosts — switch attach: multiple servers/switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
10 Connecting a USB cable to the CLI port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
11 USB device connection — CLI port. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
8Figures
AssuredSAN 2333 Setup Guide 9
Tables
1 Related documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2 Document conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3 Installation checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4 Summary of SAS cabling to attach drive enclosures to the controller enclosure . . . . . . . . . . . . . . . . . . 19
5 Terminal emulator display settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
6 Terminal emulator connection settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
7 Diagnostics LED status — Front panel “Fault/Service Required” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
8 Diagnostics LED status — Rear panel “FRU OK” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
9 Diagnostics LED status — Rear panel “Fault/Service Required” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
10 Diagnostics LED status — Disk drives (LFF and SFF modules) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
11 Diagnostics LED status — Disk drive fault status (LFF and SFF modules) . . . . . . . . . . . . . . . . . . . . . . . . 39
12 Diagnostics LED status — Rear panel “Host Link Status” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
13 Diagnostics LED status — Rear panel “Expansion Port Status” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
14 Diagnostics LED status — Rear panel “Network Port Link Status” . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
15 Diagnostics LED status — Rear panel power supply “Input Power Source”. . . . . . . . . . . . . . . . . . . . . . 41
16 Diagnostics LED status — Rear panel power supply “Voltage/Fan Fault/Service Required”. . . . . . . . . . 41
17 Power supply sensor descriptions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
18 Cooling fan sensor descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
19 Controller module temperature sensor descriptions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
20 Power supply temperature sensor descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
21 Voltage sensor descriptions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
22 LEDs — 2U12 enclosure front panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
23 LEDs — Disk with a dongle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
24 LEDs — Disks in LFF enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
25 LEDs — Vdisks in LFF enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
26 LEDs — 2333 controller module — rear panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
27 LEDs — Power supply units — rear panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
28 LEDs — 3130 rear panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
29 Power requirements - AC Input. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
30 Rackmount enclosure dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
31 Rackmount controller enclosure weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
32 Rackmount compatible drive enclosure weights (ordered separately) . . . . . . . . . . . . . . . . . . . . . . . . . 58
33 Operating environmental specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
34 Non-operating environmental specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58
35 Supported terminal emulator applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
36 USB vendor and product identification codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64
10 Tables
AssuredSAN 2333 Setup Guide 11
About this guide
This guide provides information about initial hardware setup for the AssuredSAN™ 2333 storage product
shown below:
Internet SCSI (1Gb) Controller Enclosure: 2333
AssuredSAN 2333 enclosures are designed to meet NEBS Level 3, MIL-STD-810G (storage requirements),
and European Telco requirements. The 2333 is a large form factor (LFF 12-disk) 2U controller enclosure
equipped with two controller modules and two AC power supplies.
The 2333 can optionally be cabled to 3130 drive enclosures for adding storage. The 3130 is an LFF 12-disk
2U expansion enclosure equipped with two expansion modules and two AC power supplies.
See the Dot Hill web site for more information about specific storage product models and uses:
http://www.dothill.com
.
Intended audience
This guide is intended for storage system administrators.
Prerequisites
Prerequisites for installing and using this product include knowledge of:
Servers and computer networks
Network administration
Storage system installation and configuration
Storage area network (SAN) management and direct attach storage (DAS)
Internet SCSI (iSCSI), Serial Attached SCSI (SAS), and Ethernet protocols
Related documentation
This guide refers to related documentation as shown in Table 1 below. Many of the related documents are
from AssuredSAN 3000 Series.
Table 1 Related documents
For information about See
Enhancements, known issues, and late-breaking
information not included in product documentation
Release Notes
Overview of product shipkit contents and setup tasks Getting Started
*
Installing and using optional host-based software
components (CAPI Proxy, MPIO DSM, VDS Provider,
VSS Provider, SES Driver)
AssuredSAN Installing Optional Software for Microsoft
Windows® Server
Using a rackmount bracket kit to install an enclosure
into a rack
AssuredSAN Rackmount Bracket Kit Installation
*
or
AssuredSAN 2-Post Rackmount Bracket Kit Installation
*
Obtaining and installing a license to use licensed
features
AssuredSAN 3000 Obtaining and Installing a License
Certificate File
Using the web interface to configure and manage the
product
AssuredSAN 3000 Series RAIDar User Guide
Using the command-line interface (CLI) to configure
and manage the product
AssuredSAN 3000 Series CLI Reference Guide
12 About this guide
* Printed document included in product shipkit.
For additional information, see Dot Hill’s Customer Resource Center web site: http://crc.dothill.com.
Document conventions and symbols
WARNING! Indicates that failure to follow directions could result in bodily harm or death.
CAUTION: Indicates that failure to follow directions could result in damage to equipment or data.
IMPORTANT: Provides clarifying information or specific instructions.
NOTE: Provides additional information.
TIP: Provides helpful hints and shortcuts.
Event codes and recommended actions AssuredSAN Event Descriptions Reference Guide
Identifying and installing or replacing field-replaceable
units (FRUs)
AssuredSAN 3000 Series FRU Installation and
Replacement Guide
Table 1 Related documents (continued)
For information about See
Table 2 Document conventions
Convention Element
Blue text Cross-reference links and e-mail addresses
Blue, underlined
text Web site addresses
Bold text Key names
Text typed into a GUI element, such as into a box
GUI elements that are clicked or selected, such as menu and list
items, buttons, and check boxes
Italic text Text emphasis
Monospace text File and directory names
System output
Code
Text typed at the command-line
Monospace, italic
text Code variables
Command-line variables
Monospace, bold text Emphasis of file and directory names, system output, code, and text
typed at the command-line
AssuredSAN 2333 Setup Guide 13
1Components
12-drive enclosure front panel components
NOTE: Front panel LEDs and rear panel LEDs for controller enclosures are described in LED descriptions.
Controller enclosure — rear panel layout
The diagram and table below display and identify important component items that comprise the rear panel
layout of an AssuredSAN 2333 controller enclosure.
A controller enclosure accommodates an AC power supply FRU in each of the two power supply slots (see
two instances of callout No.1 above). The controller enclosure accommodates two controller module FRUs
of the same type within the I/O module (IOM) slots (see callouts No.2 and No.3 above).
1 Enclosure ID LED
2 Disk drive status LED: OK to Remove
3 Disk drive status LED: Power/Activity/Fault
4 3.5" disk or drive blank (typical 12 slots)
5 Enclosure status LED: Unit Locator
6 Enclosure status LED: Fault/Service Required
7 Enclosure status LED: FRU OK
8 Enclosure status LED: Temperature Fault
OKOK
OK
21
5
34
6
7
8
Left ear
Right ear
Note: Integers on disks indicate drive slot numbering sequence.
0
4
8
1
5
9
2
6
10
3
7
11
1 AC power supplies
2 Controller module A
3 Controller module B
4 1Gb iSCSI ports: host interface
5 Reserved for future use
6 CLI port (USB - Type B) [see Appendix D]
7 Host port (USB - Type A; reserved for future use)
8 Network port
9 Service port (used by service personnel only)
10 Disabled button (used by engineering/test only)
[Not present on newer controller module versions]
11 Expansion port
SERVICE
CACHE
CLI
CLI
HOST
SERVICE
CACHE
CLI HOST
6Gb/s
6Gb/s
ACT
LINK
ACT
LINK
CLI
L
0 1
ALA
L
0 1
ALA
154689 117 10 1
2
3
2333 model is shown as a locator
14 Components
IMPORTANT: The 2333 controller enclosures support dual-controller configuration only. Single-controller
support is provided only when a controller fails over to its partner controller (also see the “About data
protection in a single-controller storage system” topic in the RAIDar User Guide. A controller module must
be installed in each I/O module slot to ensure sufficient airflow through the enclosure during operation.
The diagrams with tables that immediately follow provide descriptions for the different controller modules
and power supply modules that can be installed into the rear panel of a 2333 controller enclosure.
Showing controller modules and power supply modules separately from the enclosure enables improved
clarity in identifying the component items called out in the diagrams and described in the tables.
A description of the optional 3130 drive enclosure — supported by 2333 controller enclosures — is also
provided. When used with a 2333, the 3130 is equipped with dual-IOMs.
2333 controller module — rear panel components
3130 drive enclosure rear panel components
AssuredSAN 2333 controller enclosures support 3130 drive enclosures for expansion of storage capacity.
These drive enclosures use mini-SAS (SFF-8088) connectors to facilitate backend SAS expansion. See
Cable requirements for drive enclosures on page 19 for cabling information.
1 1Gb iSCSI ports: host interface
2 Reserved for future use
3 CLI port (USB - Type B) [see Appendix D]
4 Host port (USB - Type A; reserved for future use)
5 Network port
6 Service port (used by service personnel only)
7 Expansion port
L
SERVICE
0
CACHE
CLI
CLI
HOST
6Gb/s
1
ALA
ACT
LINK
2 3 6 7
45
1
1 Power supplies (AC shown)
2 Expansion module A
3 Expansion module B
4 Disabled button (used by engineering/test only)
5 Service port (used by service personnel only)
6 SAS In port
7 SAS Out port
00
IN OUT
00
IN OUT
1
5
6 74
1
2
3
AssuredSAN 2333 Setup Guide 15
Component installation and replacement
Installation and replacement of 2333 FRUs (field-replaceable units) is addressed in the AssuredSAN 3000
Series FRU Installation and Replacement Guide within the “Procedures” chapter.
FRU procedures facilitate replacement of a damaged chassis or chassis component:
Replacing a controller or expansion module
Replacing a disk drive module
Replacing a power supply unit (AC and DC units with integrated cooling fans)
(DC power supplies are not applicable to the 2333; however, they apply to 3000 Series)
Replacing ear bezels
Replacing a Fibre Channel transceiver (applies to 3000 Series only)
Replacing a 10GbE SFP+ transceiver (applies to 3000 Series only)
Replacing a controller enclosure chassis
See Dot Hill’s Customer Resource Center web site for additional information: http://crc.dothill.com
.
Select AssuredSAN & R/Evolution Products > 3000 Series to download the FRU I&R guide.
Cache
To enable faster data access from disk storage, the following types of caching are performed:
Write-back or write-through caching. The controller writes user data into the cache memory in the
controller module rather than directly to the disks. Later, when the storage system is either idle or aging
— and continuing to receive new I/O data — the controller writes the data to the disks.
Read-ahead caching. The controller detects sequential data access, reads ahead into the next
sequence of data — based upon settings — and stores the data in the read-ahead cache. Then, if the
next read access is for cached data, the controller immediately loads the data into the system memory,
avoiding the latency of a disk access.
TIP: See the “About volume cache options” and “Changing system cache settings” topics in the RAIDar
User Guide for setting options.
CompactFlash
During a power loss or controller failure, data stored in cache is saved off to non-volatile memory
(CompactFlash). The data is restored to cache, and then written to disk after the issue is corrected.
CompactFlash provides unlimited cache memory backup time. To protect against writing incomplete data
to disk, the image stored on the CompactFlash is verified before committing to disk.
The CompactFlash card is located at the midplane-facing end of the controller module as shown below. Do
not remove the card; it is used for cache recovery only.
Figure 1 CompactFlash
IMPORTANT: Customer removal of CompactFlash will void the product warranty.
CompactFlash card
Controller module
16 Components
Super-capacitor pack
To protect controller module cache in case of power failure, each controller enclosure model is equipped
with super-capacitor technology, in conjunction with CompactFlash memory, built into each controller
module to provide unlimited cache memory backup time. The super-capacitor pack provides energy for
backing up unwritten data in the write cache to the CompactFlash, in the event of a power failure.
Unwritten data in CompactFlash memory is automatically committed to disk media when power is restored.
In the event of power failure, while cache is maintained by the super-capacitor pack, the Cache Status LED
flashes at a rate of 1/10 second on and 9/10 second off.
AssuredSAN 2333 Setup Guide 17
2Installing the enclosures
Installation checklist
The following table outlines the steps required to install the enclosures, and initially configure and provision
the storage system. To ensure successful installation, perform the tasks in the order presented.
1
Also see AssuredSAN 3000 Series FRU Installation and Replacement Guide for illustrations showing installation of enclosure ear
caps (some enclosure models use an enclosure bezel instead of ear caps).
2
For more about hosts, see theAbout hosts” topic in the AssuredSAN 3000 Series RAIDar User Guide.
3
RAIDar is introduced in Accessing RAIDar on page 33. See the RAIDar User Guide or online help for additional information.
NOTE: Additional installation notes:
Controller modules within the same enclosure must be of the same type.
For optimal performance, do not mix 6Gb and 3Gb disk drives within the same enclosure.
Network Equipment-Building System (NEBS) Level 3 compliance
Generic Requirements (GRs)
Meets the NEBS requirement of GR-1089-CORE Issue 5, port types 2, 7 & 8.
Meets the NEBS requirements of GR-63-CORE Issue 3, for the product’s intended use.
NOTE: Table 4 on page 19 shows NEBS-compliance for individual storage enclosures.
Table 3 Installation checklist
Step Task Where to find procedure
1. Install the controller enclosure and optional
drive enclosures in the rack, and attach ear
caps or enclosure bezel.
1
See the rack-mount bracket kit installation instructions
pertaining to your enclosure. If your product uses a bezel,
see its bezel kit installation instructions.
2. Connect controller enclosure and optional
drive enclosures.
See Connecting the controller enclosure and drive enclosures
on page 18.
3. Connect power cords. See Powering on/powering off on page 23.
4. Test enclosure connectivity. See Testing enclosure connections on page 23.
5. Install required host software. See Host system requirements on page 25.
6. Connect hosts.
2
See Connecting the enclosure to hosts on page 25.
7. Connect remote management hosts.
2
See Connecting a management host on the network,
page 28.
8. Obtain IP values and set network port IP
properties on the controller enclosure.
See Obtaining IP values on page 29.
For USB CLI port and cable use, see Appendix D.
Also see the ship kit CD.
9. Perform initial configuration tasks
3
:
Sign-in to the web-based storage
management application (RAIDar).
Initially configure and provision the system
using RAIDar.
Topics below correspond to bullets at left:
See “Getting Started” in the web-posted AssuredSAN 3000
Series RAIDar User Guide.
See “Configuring the System” and “Provisioning the System
topics in the RAIDar User Guide or online help.
18 Installing the enclosures
Exceptions to GRs
Exceptions to the overall NEBS GR-63-CORE Issue 3 requirements include:
Heat Dissipation: Environmental Criteria Section 4.1.6, Operational Requirement O4-20. This product
exceeds the Optional Requirements shown in Table 4-5 for Forced-Air Fan Shelf equipment.
Airborne Contaminants: This product is designed for indoor use only, and has not been tested for
Outdoor Contaminant Levels (Table 4-11); per Requirement R4-86 (Environmental Criteria section
4.5.2.2).
Equipment — Fan Filters: Environmental Criteria Section 4.5.4. This product does not have a fan filter,
and has not been tested by any requirements in section 4.5.4. The following requirements have not
been tested: R4-87 [138]; R4-88 [139]; R4-89 [176]; R4-90 [140]; R4-91 [141]; R4-92 [142];
R4-93 [143]; O4-94 [144] and O4-95 [145].
This product does not meet the requirements of Spatial Requirements, Section 2.
Exceptions to the overall NEBS GR-1089-CORE Issue 5 requirements include:
None reported
Product documentation requirements
NEBS product documentation requirements applying to AssuredSAN 2333 controller and drive enclosures
are listed beneath “NEBS (Level 3)” in the Index — under either GR-1089-CORE Issue 5 or GR-63-CORE
Issue 3 — together with adjacent page locations. NEBS topics are integrated within the overall content of
this setup guide. The requirement designators in the Index have been codified for use within index marker
tags according to the following example:
NEBS generic requirement number “R2-7 [7]” appears as “R2-7.7” within the Index.
Each codified string (e.g., R2-7.7) is followed by a hyphen and brief description of the requirement. Within
the Index, click on the blue page number link to navigate to the corresponding NEBS topic.
Connecting the controller enclosure and drive enclosures
AssuredSAN 2333 controller enclosures — available in12-drive (3.5") chassis — support up to eight
enclosures (including the controller enclosure), or a maximum of 96 disk drives. 2333 enclosures support
both straight-through and reverse SAS cabling. Reverse cabling allows any drive enclosure to fail — or be
removed — while maintaining access to other enclosures. Fault tolerance and performance requirements
determine whether to optimize the configuration for high availability or high performance when cabling.
AssuredSAN 2333 controller modules support both 3-Gbps and 6-Gbps internal disk drive speeds
together with 3-Gbps and 6-Gbps expander link speeds.
CAUTION: Some 6-Gbps disks might not consistently support a 6-Gbps transfer rate. If this happens, the
system automatically adjusts transfers to those disks to 3 Gbps, increasing reliability and reducing error
messages with little impact on system performance. This rate adjustment persists until the controller is
restarted or power-cycled.
Cabling diagrams in this section show fault-tolerant cabling patterns. Controller and expansion modules
are identified by <enclosure-ID><controller-ID>. When connecting multiple drive enclosures, use
reverse cabling to ensure the highest level of fault tolerance, enabling controllers to access remaining drive
enclosures if a drive enclosure fails.
For example, the illustration on the left in Figure 3 on page 21 shows reverse cabling, wherein
controller 0A (i.e., enclosure-ID = 0; controller-ID = Able) is connected to expansion module 1A, with a
chain of connections cascading down (blue). Controller 0B is connected to the lower expansion
module (B) of the last drive enclosure in the chain, with connections moving in the opposite direction
(green). Several cabling examples are provided on the following pages.
AssuredSAN 2333 Setup Guide 19
NOTE: AssuredSAN 2333 controller enclosures support hot-plug replacement of redundant controller modules,
fans, power supplies, and I/O modules. Hot-add of drive enclosures is also supported.
Cable requirements for drive enclosures
2333 enclosures support 6-Gbps or 3-Gbps expansion port data rates. Observe the following guidelines
when installing SAS cables (see Table 4 below):
Use only AssuredSAN or OEM-qualified SAS cables appropriate for connecting the drive enclosure:
For 6-Gbps drive enclosures, use cables providing 6-Gbps data rate per lane with four lanes (4x)
per SAS connector:
When connecting a controller enclosure to a drive enclosure, the cable length should not exceed
2.0 meters
When connecting drive enclosures to one another, cable lengths should not exceed 2.0 meters
Qualified cables of 0.6 meter length may be used for cabling stacked components in cascaded
fashion
Mini-SAS to mini-SAS cables denote SFF-8088 to SFF-8088 connectors
You may need to order additional or longer cables when reverse-cabling a fault-tolerant configuration
(see Figure 4 on page 22).
TIP: Requirements for cabling 2333 controller enclosures and supported drive enclosures are
summarized in Table 4 on page 19.
Table 4 summarizes key characteristics of controller enclosures and compatible drive (expansion)
enclosures relative to cabling, including: the cable type needed for attaching one specific enclosure
model to another specific enclosure model; internal disk drive speeds; number of disks of given size
(SFF or LFF) supported per enclosure model; and SAS expander data rates. Enclosure form factor
(2U24/2U12) and NEBS compliance information are also provided.
NOTE: Additional cabling notes:
Cables required, if not included, must be separately purchased.
Spanning a single drive enclosure requires a 0.6 m (1.97') cable.
When adding more than two drive enclosures, you may need to purchase additional 1 m or 2 m
cables:
Spanning 3, 4, or 5 drive enclosures requires 1 m (3.28') cables.
Spanning 6, 7, 8, or 9 drive enclosures requires 2 m (6.56') cables.
Table 4 Summary of SAS cabling to attach drive enclosures to the controller enclosure
Enclosure models
2U12 controller enclosure
2U24 drive enclosure 2U12 drive enclosure
2333 1Gb iSCSI
Not applicable
Not applicable
mini-SAS to mini-SAS
3130 (LFF 12-drive) mini-SAS to mini-SAS mini-SAS to mini-SAS
Enclosure chassis designators:
2U24: Enclosure measuring two rack units high, providing 24 SFF (2.5") disks (Not used with
2333
).
2U12: Enclosure measuring two rack units high, providing 12 LFF (3.5") disks.
Compatible product models featuring 6 Gbit/s internal disk and SAS expander link speeds:
2333: 1Gb iSCSI dual-IOM controller enclosure (3.5" disks in 2U12 chassis) [NEBS]
3130 dual-IOM drive enclosure: 12-drive expansion enclosure (3.5" disks in 2U12 chassis) [NEBS]
See Physical requirements on page 57 for more information about 2U24 and 2U12 enclosures.
20 Installing the enclosures
NOTE: For clarity, the schematic diagrams show only relevant details such as face plate outlines and
expansion ports. For detailed illustrations, see Controller enclosure — rear panel layout on page 13. Also
see the controller module face plate illustration that follows the rear panel layout.
Summary of drive enclosure cabling illustrations
The following illustrations show both straight-through and reverse cabling examples featuring 2333
controller enclosures and 3130 (2U12) drive enclosures. All enclosures use mini-SAS connectors.
NOTE: 2333 controller enclosures and compatible 3130 drive enclosures support mini-SAS SFF-8088
connectors for adding storage. See Table 4 on page 19 for SAS cable requirements.
Figure 2 Cabling connections between a controller enclosure and one drive enclosure
The diagram above shows a 2333 controller enclosure equipped with dual-controller modules cabled to a
3130 drive enclosure equipped with dual-expansion modules.
IMPORTANT: The 2333 controller enclosures support dual-controller configuration only. Single-controller
support is provided only when a controller fails over to its partner controller. A controller module must be
installed in each I/O module slot to ensure sufficient airflow through the enclosure during operation.
See “Replacing a controller or expansion module” within the AssuredSAN 3000 Series FRU Installation
and Replacement Guide for additional information.
Controller
enclosure
0
Drive
enclosure
1
In Out
In Out
0B
0A
1A
1B
Controller A
Controller B
Enclosures equipped with dual IOMs
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70

Seagate Assuredsan- 2333 Series Installation guide

Category
Gateways/controllers
Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI