Instruction Manual
Thermo Flame Ionization Detector
FID Analyzer or Analyzer Module (combined with NGA
2000 Platform, MLT or CAT 200)
2
nd
Edition 04/2008
Instruction Manual
90003806
04/2008
TFID Thermo Flame Ionization Detector Instruction Manual
90003806
04/2008
Emerson Process Management
GmbH & Co. OHG
Industriestrasse 1
D-63594 Hasselroth
Germany
T +49 (0) 6055 884-0
F +49 (0) 6055 884-209
Internet: www.EmersonProcess.com
ESSENTIAL INSTRUCTIONS
READ THIS PAGE BEFORE PROCEEDING!
Emerson Process Management (Rosemount Analytical) designs, manufactures and tests
its products to meet many national and international standards. Because these instruments
are sophisticated technical products, you MUST properly install, use, and maintain
them to ensure they continue to operate within their normal specifications. The following
instructions MUST be adhered to and integrated into your safety program when installing,
using and maintaining Emerson Process Management (Rosemount Analytical) products.
Failure to follow the proper instructions may cause any one of the following situations to
occur: Loss of life; personal injury; property damage; damage to this instrument; and warranty
invalidation.
Read all instructions prior to installing, operating, and servicing the product.
If you do not understand any of the instructions, contact your Emerson Process
Management (Rosemount Analytical) representative for clarification.
Follow all warnings, cautions, and instructions marked on and supplied with the product.
Inform and educate your personnel in the proper installation, operation, and
maintenance of the product.
Install your equipment as specified in the Installation Instructions of the appropriate
Instruction Manual and per applicable local and national codes. Connect all products
to the proper electrical and pressure sources.
To ensure proper performance, use qualified personnel to install, operate, update, program,
and maintain the product.
When replacement parts are required, ensure that qualified people use replacement parts
specified by Emerson Process Management (Rosemount Analytical). Unauthorized parts
and procedures can affect the product’s performance, place the safe operation of your
process at risk, and VOID YOUR WARRANTY. Look-alike substitutions may result in fire,
electrical hazards, or improper operation.
Ensure that all equipment doors are closed and protective covers are in place, except
when maintenance is being performed by qualified persons, to prevent electrical
shock and personal injury.
The information contained in this document is subject to change without notice. Misprints
reserved.
1
st
Edition 06/1998
2
nd
Edition 04/2008
©
2008 by Emerson Process Management
CONTENTS
I
90003806(1) NGA-TFID e 16.06.98
Rosemount Analytical
Table of Contents
SAFETY SUMMARY S - 1
General S - 2
Gases and Gas Conditioning (Sample Handling) S - 3
Supply Voltage S - 4
Analyzer specific notes for the user S - 5
Additional notes for service / maintenance S - 6
Electrostatic Discharge S - 7
PREFACE P - 1
DESCRIPTION
1. Technical Description 1 - 1
1.1 Front View 1 - 1
1.2 Rear Panel 1 - 3
1.3 Internal Construction 1 - 4
1.3.1 Thermo-FID Assembly 1 - 5
1.3.2 Printed Circuit Boards 1 - 6
1.4 Applications 1 - 8
2. Theory of Technology and Operation 2 - 1
2.1 Measuring Principle 2 - 1
2.2 TFID Mode of Operation 2 - 3
2.3 Sample Gas Transport 2 - 4
3. (vacant)
4. (vacant)
CONTENTS
II
90003806(1) NGA-TFID e 16.06.98
Rosemount Analytical
OPERATION
5. Preparation 5 - 1
5.1 Installation Site 5 - 2
5.2 Gas Conditioning (Sample Handling) 5 - 3
5.3 Gases 5 - 4
5.3.1 Supply Gases 5 - 4
5.3.2 Gas Connections 5 - 5
6. Switching On 6 - 1
7. Switching Off 7 - 1
8.
- (vacant)
14.
MAINTENANCE
15. Opening the Housing 15 - 1
15.1 Housing Cover 15 - 1
15.2 Front Panel 15 - 1
16.
- (vacant)
18.
19. Cleaning of Housing Outside 19 - 1
CONTENTS
III
90003806(1) NGA-TFID e 16.06.98
Rosemount Analytical
TECHNICAL DATA 20 - 1
20.1 Housing 20 - 1
20.2 Ambient Conditions 20 - 2
20.3 General Specifications 20 - 3
20.4 Voltage supply 20 - 3
20.4.1 Electrical Safety 20 - 4
20.5 Response Factors 20 - 4
SUPPLEMEMT
21. Pin Assignments 21 - 1
21.1 230 or 115 Vac (Input and Output) 21 - 1
21.2 Pt 100 (external heater) 21 - 1
21.3 Option SIO (Standard Input/Output Module) 21 - 2
21.3.1 Analog Signal Outputs 21 - 2
21.3.2 Relay Outputs / Serial Interfaces 21 - 2
21.4 Option DIO (Digital Input/Output Module) 21 - 3
21.4.1 Wiring with external actors 21 - 4
21.5 COM - Ports (for service use only) 21 - 6
INDEX I - 1
List of Figures I - 4
CONTENTS
IV
90003806(1) NGA-TFID e 16.06.98
Rosemount Analytical
SAFETY SUMMARY
S - 1
90003806(1) NGA-TFID e 16.06.98
Rosemount Analytical
Safety Summary
Outside and/or inside TFID or at operation manual resp. different symbols gives you a hint to
special sources of danger.
Source of danger !
See Operation Manual!
High Voltage !
Electrostatic Discharge (ESD) !
Explosives !
Hot components !
Toxic !
Risk to health !
Analyzer specific notes for the user !
In operation manual we will give partly additional informations to these symbols.
Strictly follow these instructions please !
GENERAL
SAFETY SUMMARY
S - 2
90003806(1) NGA-TFID e 16.06.98
Rosemount Analytical
GENERAL
1. General
The following general safety precautions must be observed during all phases of operation,
service and repair of this instrument !
Failure to comply with these precautions or with specific warnings elsewhere in this manual
violates safety standards of design, manufacture and intended use of this instrument !
Failure to comply with these precautions may lead to personal injury and damage to this
instrument !
Fisher-Rosemount GmbH & Co. does not take responsibility (liability) for the customer´s
failure to comply with these requirements !
Do not attempt internal service or adjustment unless other person, capable of rendering first
aid and resuscitation, is present !
Because of the danger of introducing additional hazards, do not perform any unauthorized
modification to the instrument !
Return the instrument to a Fisher-Rosemount Sales and Service office for service or repair
to ensure that safety features are maintained !
Instruments which appear damaged or defective should be made inoperative and secured
against unintended operation until they can be repaired by qualified service personnel.
SAFETY SUMMARY
S - 3
90003806(1) NGA-TFID e 16.06.98
Rosemount Analytical
GENERAL / GASES AND GAS CONDITIONING (SAMPLE HANDLING)
Operating personnel must not remove instrument covers !
Component replacement and internal adjustments must be made by qualified
service personnel only !
Read all operation manuals before attempting to operate with the instrument !
Be sure to observe the additional notes, safety precautions and warnings given
in the individual operation manuals (e. g. platform, analyzer modules and
I/O-modules) !
Do not operate the instrument in the presence of flammable gases or explosive
atmosphere without supplementary protective measures !
At heated components there could be exist hot components !
If any moisture or objects come into the internal of the instrument disconnect
power and all supply gases.
2. Gases and Gas Conditioning (Sample Handling)
Be sure to observe the safety regulations for the respective gases
(sample gas and test gases / span gases) and the gas bottles !
All pneumatic supplies and mains, especially the hydrogen mains, have to be
tight ! All gases used must have the right input pressure !
Inflammable or explosive gas mixtures must not be purged into the instrument
without supplementary protective measures !
To avoid a danger to the operators by explosive, toxic or unhealthy gas
components, first purge the gas lines with ambient air or nitrogen (N
2
) before
cleaning or exchange parts of the gas paths.
SAFETY SUMMARY
S - 4
90003806(1) NGA-TFID e 16.06.98
Rosemount Analytical
SUPPLY VOLTAGE
3. Supply Voltage
The socket outlet shall be installed near the equipment and shall be easily
accessible to disconnect the device from the socket outlet.
Verify before operation whether the line voltage stated on the label of the
instrument ore power supply agrees with that of your mains line!
Do not put any object on the supply voltage cable. Install the line voltage cable
in such a manner that nobody can step on it or fall over it.
Protect the line voltage and signal cables for damage and moisture ingress.
This product is a Safety Class 1 instruments
This product is provided with a protective earth terminal.
To prevent shock hazard, the instrument chassis and cabinet must be connected
to an electrical ground. The instrument must be connected to the AC power
supply mains through a three-conductor power cable, with the third wire firmly
connected to an electrical ground (safety ground) at the power outlet.
If the instrument is to be energized via an external power supply, that goes for the
power supply too.
Any interruption of the protective (grounding) conductor or disconnection of the
protective earth terminal will cause a potential shock hazard that could result in
personal injury. Deliberate disconnection is inadmissible / prohibited !
SAFETY SUMMARY
S - 5
90003806(1) NGA-TFID e 16.06.98
Rosemount Analytical
4. Analyzer specific notes for the user
First of all operations unscrew transfer safety lock (knurled-head screws)
for the optional sucking pump of the analyzer (Item 5. of operation manual) !
The installation site for the instrument has to be dry and remain above freezing
point at all times.
The instrument must be exposed neither to direct sunlight nor to strong sources
of heat. Be sure to observe the permissible ambient temperature !
For outdoor sites, we recommend to install the instrument in a protective cabinet.
At least, the instrument has to be protected against rain (e.g., shelter).
Free flow of air into and out of the equipment must not be hindered by
nearby objects or walls !
For rack installation be sure, that the TFID has space on top and on bottom of
min. 1/2 HU to avoid overheating !
Do not interchange gas inlets and gas outlets !
All gases have to be supplied to the analyzer as conditioned gases !
When the instrument is used with corrosive gases, it is to be verified that there
are no gas components which may damage the gas path components.
The exhaust gas lines have to be mounted in a declining, descending,
pressureless and frost-free and according to the valid emission legislation !
In case it is necessary to open the gas paths, close the analyzers
gas connections with PVC caps immediatly !
Use only from our factory optional delivered cables or equivalent shielded cables
to be in agreement with the CE - conformity.
The customer has to guarantee, that the shield is be connected bothsided.
Shield and connectors housing have to be connected conductive.
Sub.-min.-D-plugs/sockets have to be screwed to the analyzer.
By using of optional delivering terminal strip adapters the analyzer is not be in
agreement with the CE - conformity. In this case CE - conformity is to be declared
by customer as “manufacturer of system”.
ANALYZER SPECIFIC NOTES FOR USER
SAFETY SUMMARY
S - 6
90003806(1) NGA-TFID e 16.06.98
Rosemount Analytical
5. Additional notes for service / maintenance
Operating personnel must not remove instrument covers !
Component replacement and internal adjustments must be made by qualified
service personnel only !
Always disconnect power, discharge circuits and remove external voltage
sources before troubleshooting, repair or replacement of any component !
Any work inside the instrument without switching off the power must be
performed by a specialist, who is familiar with the related danger, only !
In case of exchanging fuses the customer has to be certain that fuses of specified
type and rated current are used. It is prohibited to use repaired fuses or defective
fuse holders or to short-circuit fuse carriers (fire hazard).
In case of exchanging optional sucking pump, verify whether the line voltage
stated on the label of the TFID agrees with that of the sucking pump !
At component replacement or installation the RF shielding contacts must not be
bended !
ADDITIONAL NOTES FOR SERVICE / MAINTENANCE
SAFETY SUMMARY
S - 7
90003806(1) NGA-TFID e 16.06.98
Rosemount Analytical
5.1 Electrostatic Discharge
The electronic parts of the analyzer can be irreparably damaged if exposed to electrostatic
discharge (ESD).
The instrument is ESD protected when the covers have been secured and safety precautions
observed. When the housing is open, the internal components are not ESD protected anymore.
Although the electronic parts are reasonable safe to handle, you should be aware of the following
considerations:
Best ESD example is when you walked across a carpet and then touched an electrical grounded
metal doorknob. The tiny spark which has jumped is the result of electrostatic discharge (ESD).
You prevent ESD by doing the following:
Remove the charge from your body before opening the housing and maintain during work with
opened housing, that no electrostatic charge can be built up.
Ideally you are opening the housing and working at an ESD - protecting workstation.
Here you can wear a wrist trap.
However, if you do not have such a workstation, be sure to do the following procedure exactly:
Discharge the electric charge from your body. Do this by touching a device that is grounded
electrically (any device that has a three - prong plug is grounded electrically when it is plugged into
a power receptacle).
This should be done several times during the operation with opened housing (especially after
leaving the service site because the movement on a low conducting floors or in the air might cause
additional ESDs).
ELECTROSTATIC DISCHARGE
SAFETY SUMMARY
S - 8
90003806(1) NGA-TFID e 16.06.98
Rosemount Analytical
P - 1
PREFACE
90003806(1) NGA-TFID e 16.06.98
Rosemount Analytical
Preface
The Thermo-FID (TFID) as member of the NGA 2000 familiy has all the advantages of a modular
analyzer system. A TFID Analyzer Module (AM) as “blind” analysis unit it can be part of a multiple
NGA analyzer system or special customer-developed control unit. TFID with front panel display/
operator interface is a stand-alone analyzer or central interface (control module) for multiple
analyzer modules.
The TFID is used in several areas of industry, safety of environment, research and develop-ment.
Typical applications are the LEL control, the emission and ambient air control or the exhaust gas
analysis in the chemistry and combustion engine development. But you can also use the TFID to
optimize a process or to control any limits at operating position.
A lot of auxiliary functions are available by the micro electronic of the TFID. The integrated CPU
allows the operation via menu, the automatic self control and error diagnostics. The display shows
all instruction notes and auxiliary reports in plain language. The very small currents of the FID
detector are always evaluated in the optimum range by the processor controlled dynamic amplifier.
The amplified signals will be digitalized directly at the detector and sent out to the CPU. So, a
falsification of the small detector signal will become impossible and the high resistant screened
cable will become unnecessary.
Technical Properties of Measurement
Integrated licensed backfiring flame trap of the “Ex s IIC class”
Electronic control of the sample gas flow
Electronic control of the accelerating voltage
Flame control with automatic ignition
Electronic control of the ignition power
Automatic calibration of the flame size
Self calibration without any other valves or components
Large range of linearization without switching of the coupling
FID amplifier and A/D transformer are connected with the detector directly wireless
Integrated thermic catalyst for burning air, zero gas and stripper
Determination of organic carbon (org. C) in superheat vapor or condensate
Determination of organically bound carbon down to LEL
Determination of organically bound carbon according to “17
th
BImSchV” (in progress)
P - 2
PREFACE
90003806(1) NGA-TFID e 16.06.98
Rosemount Analytical
TECHNICAL DESCRIPTION
1 - 1
90003806(1) NGA-TFID e 22.06.98
Rosemount Analytical
1. Technical Description
All components of analyzer or analyzer module are incorporated into a 1/1 19" housing.
The housing is available as rack mounting (R) or as table-top (T) versions. For analyzer modules
there is mounted a blind plate instead of an operation front panel.
The Flame Ionization Detector (FID) is designed to continuously determine concentrations of
hydrocarbons.
The TFID offers the following Advantages:
a) The instrument is designed modular according to function groups resulting in:
Easy troubleshooting
Fast error removal
High availability
b) The analyzer is sucking automatically sample gas via a pump system being installed behind
the detector.
c) The sample gas is sucked direct into the detector without using a superposed sample gas
pump. Therefrom:
No heated sample gas pump
No additional heating of sample gas inlet (or heated bypass as option)
No “cold” connections leading to condensation; in that way avoiding corrosion and
signal falsification
Fast response (to achieve values)
1.1 Front View
The front panel of the analyzer is the operating front panel (see Fig. 1-1).
Measured values and the entire operating procedure are displayed on a LC display. The operation
and programming of the instrument is performed by using the four cursor keys, the ENTER key
and the five soft keys
For analyzer modules there is mounted a blind plate instead of an operation front panel.
TECHNICAL DESCRIPTION
1 - 2
90003806(1) NGA-TFID e 16.06.98
Rosemount Analytical
Fastening screws for rack mounting or carrying-strap bracket
ENTER key
LC display
Cursor keys
Soft keys
(function is depending on Software Menu)
Fastening screws for rack mounting or carrying-strap bracket
Fig. 1-1: Operation front panel, Front view
FRONT PANEL
Fig. 1-2: TFID, Front view
optional Fan
(together with internal sucking pump option)
Blind plate or
operation front panel
TECHNICAL DESCRIPTION
1 - 3
90003806(1) NGA-TFID e 16.06.98
Rosemount Analytical
REAR PANEL
1.2 Rear Panel
On the rear panel the connector for 230 or 115 Vac supply, the gas connections, the network
connections and the connectors of optional PCBs (see optional, separate Operation Manuals) are
accommodated.
Fig. 1-3: TFID, Rear view
Network connection
(RJ 45 socket)
Input 230 or 115 Vac
Gas connections
(Item 5.3)
optional PCB
[SIO/DIO e.g.]
Connection Pump Control
for optional internal sucking pump
(Sub. Min. D. 9 pin)
Gas connections
(optional internal
sucking pump)
Output 230 or 115 Vac
(max. 4 A)
TECHNICAL DESCRIPTION
1 - 4
90003806(1) NGA-TFID e 22.06.98
Rosemount Analytical
INTERNAL CONSTRUCTION
1.3 Internal Construction
By frontal view, the electronic unit with interconnection PCB and other PCBs is located on the right.
The analysis assembly and other parts are located on the left.
analysis assembly internal power supply optional I/O-boards
ACU PCB
sucking pump
(option)
front panel
Fig. 1-4: TFID, internal construction
PCB LEM 02
(network in)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64

Rosemount NGA 2000 TFID Hydrocarbon Analyzer Module Hardware -2nd Ed. Owner's manual

Category
Power heat guns
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI