The downstream level (DS) into the transponder should be ± 15dBmV. However, for optimal performance, set the level as
close to 0 dBmV as possible
Verifying Installation and Network Connectivity
• Once the rmware initializes, the LED sequence is as follows:
1. POWER LED on; all other LEDs off
2. DS, US ashing intermittently
3. ONLINE LED ashing fast and slow until registration is complete
4. ONLINE LED on solid indicating IP address has been assigned
5. DS ickering as data are sent from transponder to Network Management System
• Once the AM MIBs have been set through the network using SNMP, the network connection can be remotely veried
by entering the IP address into a web browser and conrming the display of correct power supply measurements.
For additional product information, refer to the XP-EDH-A2 technical manual (P/N 745-838-B2).
Generic Power Supplies
Switch the battery breaker OFF.
9VAC
120VAC
TO
220VAC
NEMA 6-15P
220V US
9VAC
3 FT CORD
IEC C13
TO
CBLPS-PWR-02-002
Alpha P/N 875-718-10
CBLPS-PWR-04-001
Alpha P/N 875-717-10
or
Necessary Cables
NOTE:
0A C4 36
DOCSIS Transponder
AlphaNet
To Load
To Batteries
For any power supply that has a compatible
output power connector, the XP-EDH-A2 can
monitor the following parameters:
• Input V
• Output V
• Battery string V
• Individual battery V
• Temperature
System RF
Cable In
To Battery Harness
Provides Input Voltage Monitoring
Power Output Cable
with Transformer
120Vac P/N 875-718-10
220Vac P/N 875-717-10
A
A
The power supply must be disconnected from line
voltage during installation.