Jumper functions
Jumper ON OFF
J01
Upslope
Upslope angle is constant, time is dependant
on the set value.
Upslope set time remains constant, not
depending on the set value.
J02
Downslope
Downslope angle is constanttime is
dependant on the set value.
Downslope set time remains constant, not
depending on the set value.
J03
TIG antifreeze
TIG antifreeze is on. TIG antifreeze is not on.
J04
AC balance
Manual AC balance adjustment. Balance automatics is on.
J05
Tacking automatics
Tacking automatics is disabled. Tacking automatics is enabled.
J06
Downslope cut-off
level
The downslope drops to minimum current
(3A DC, 10A AC).
The downslope drops to the end level,
which is 20% of the welding current.
J07
OCV
OCV is 39V. (22V/VRD) OCV is 70V.
J08
“china logic”
In the ending of the 4T function the
downslope is started by pressing the torch
switch. The downslope is on while the
switch is pressed, welding current is cut-off
when the switch is released. If it is pressed
for a longer time than the downslope, then
the current remains on the end current level
(see J06).
Normal 4T function.
J09
Inverter frequency
Inverter frequency is 18 kHz on the whole
current level.
Inverter frequency is 18kHz/36kHz on
MMA.
J10
2T hot/soft-start
Hot/soft–start is in use wit TIG 2T-function. Hot/soft–start is not in use with TIG 2T-
function.
J11
2T hot/soft–start
time adjustment
Hot/soft–start time with 2T-function.
Adjustment range is 0,0- 9,9 s.
J12
2T downslope
On 2T the downslope is not cut-off by a
short (nor long) press on the switch.
On 2T the welding is stopped by a short
pres on the switch during the downslope.
J13
AC-welding positive
half-cycle
On AC-TIG the height of the pos. half-cycle
is the same as the negative half-cycle´s
height.
On AC-TIG the height of the pos. half-
cycle depends on the set value and balance
adjustments.
J14
Start switch short
press
Torch switch short press time limit is 0,3 s. Torch switch short press time limit is 0,7 s.
J15
AC-TIG start cycle
AC-TIG-welding is started with a negative
half-cycle.
AC-TIG-welding is started with a positive
half-cycle.
J16
AC-TIG start cycle
length
Length adjustment for the DC start of the
positive half cycle in AC-TIG 0.0 .... 2.0.
Factory setting is 1.
J17
MMA ignition pulse
MMA ignition pulse height adjustment 0.0
..... 2.0.
Factory setting is 1.
J18 --
J19 --
11