  • Hello! I am an AI chatbot trained to assist you with the Gefen GEF-DVI-32432 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
1080P
www.gefenpro.com
32x32 DVI Matrix
GEF-DVI-32432
User Manual
ASKING FOR ASSISTANCE
Technical Support:
Telephone (818)772-9100
(800)545-6900
Fax (818)772-9120
Technical Support Hours:
8:00AMto5:00PMMondaythroughFriday,PacicTime
For24/7support,seethebackoftheproductforthesupportnumber
Write To:
Gefen,LLC
c/oCustomerService
20600NordhoffSt
Chatsworth,CA91311
www.gefenpro.com
Notice
GefenLLCreservestherighttomakechangesinthehardware,packagingandany
accompanyingdocumentationwithoutpriorwrittennotice.
32x32 DVI Matrix isatrademarkofGefenLLC
©2012Gefen,LLC.Allrightsreserved.
Alltrademarksarethepropertyoftheirrespectiveowners.
Rev A3
CONTENTS
1 Introduction
2 OperationNotes
3 Features
4 FrontPanelLayout
5 FrontPanelDescriptions
6 BackPanelLayout
7 BackPanelDescriptions
8 Connectingthe32x32DVIMatrix
8 WiringDiagram
9 Operatingthe32x32DVIMatrix
9 MainDisplay
9 DisplayingAdditionalInformation
10 DisplayingtheCurrentRoutingState
11 ModeButtons
11 RoutingSources
13 SystemLockMode
14 CancellingaFunction
15 CyclingbetweenInformationScreens
16 SavingthecurrentRoutingState
18 RecallingastoredRoutingState
20 MaskingOutputs
22 EDIDManagement
22 SavingtheDownstreamEDIDdatatoLocalmemory
24 SavingtheDefaultEDIDtoLocalmemory
26 RS-232Control
27 IPConguration
28 RS-232/TelnetCommands
28 EDIDManagement
37 IPConguration
48 Masking
50 Routing
56 System
67 WebInterface
67 Routing
77 Status
79 ManageEDID
83 Conguration
87 FirmwareUpdate
91 RackMountSafetyInformation
92 Specications
93 Warranty
94 Licensing
1
Congratulationsonyourpurchaseofthe32x32DVIMatrix.Yourcompletesatisfactionis
veryimportanttous.
GefenPRO
Intherealmofvideodistribution,certainfeaturesareinvaluableinacommercialor
broadcastenvironment.Accommodationssuchasabuild-inpowersupplyandatblack
rack-mountenclosuressetGefenPROapartfromourtraditionalproducts.Complex
distributionunitsallowforprofessionalDVI,3G-SDI,andHDMIsignalstoberoutedand
convertedeasilyandseamlessly,whilebeingbackedupbyarenownedanddependable
technicalsupportteam.GefeninvitesyoutoexploretheGefenPROproductlineandhopes
thatyoundthesolutionthattsyourneeds.
The Gefen 32x32 DVI Matrix
TheGefenPRO32x32DVIMatrixisamodulardesignforprofessionals.Eachinputcan
routedifferentresolutionsatanytimetoanydisplaybyswitchingfromtheincludedIR
Remote,IPcontrol,RS-232,orbyusingthefront-panelpushbuttons.Thefront-panel
displayprovidesinformationonroutingstatus.Removableinputandoutputmodulesand
dual(redundant)hot-swappablepowersuppliesallowtheMatrixtobeusedinthemost
demandingenvironments,offeringmaximumexibilityforallapplications.
How It Works
TheGefenPRO32x32DVIMatrixhas32DVIinputsand32DVIoutputs.UsingDVIcables,
connect32sourcestotheDVIinputportsontheGefenPRO32x32DVIMatrix.Connectthe
GefenPRO32x32DVIMatrix’s32DVIoutputstothemonitors.ConnectanEthernetcable
fromthenetworktotheRJ-45connectortousethebuilt-inIPinterfacetocontrolrouting,
EDID,andothercommands.ConnectanRS-232cablefromanRS-232controldeviceto
controltheMatrixviaRS-232.PluginthepowercordandpowerontheGefenPRO32x32
DVIMatrix.Theconnectedmonitorswillshowvideoaccordingtotheroutingselection.
INTRODUCTION
2
READ THESE NOTES BEFORE INSTALLING OR
OPERATING THE 32X32 DVI MATRIX
• Thereisnointernalscalinginthe32x32DVIMatrix.Alloftheattachedmonitors
mustbeabletodisplaytheresolutionsoutputbythesourcedevices.Formaximum
compatibilityitisrecommendedthatonlyonecompatible/commonresolutionbeused
byallofthesourcedevices.
• Routingfeaturescanbeaccessedusingtheserialcontrolinterface,Telnet,orthe
built-inWebInterface.Seepage26-86formoreinformation.
OPERATION NOTES
IMPORTANT:Iftheunitisinstalledinaclosedormulti-rack
assembly,donotblocktheventilationholesoftheenclosure.
3
Features
• Combine32cross-platformcomputersand32digitaldisplays
• Supportsresolutionsupto1080pFullHDand1920x1200
• AdvancedEDIDmanagementpermitsuploadofcustomsettings
• RS-232Serialinterfaceforremotecontrolviaacomputerorcontrolautomation
systems
• LCDstatuswindow
• Front-panelpushbuttonsforlocalswitching
• IP/TelnetControlwithbuilt-inWebserver
• Routingstatescanbestoredandrecalledatthetouchofabutton
• Built-indual(redundant)hot-swappablepowersupplies
• Outputmaskingcommand
• Standbymode
• Groundingscrew
• Fanmodule(optional)
• Filtermodule(optional)
• PowerON/OFFswitch
• SupportsDDWGstandardsforDVI
• Rack-mountable
Package Includes
(1)GefenPRO32x32DVIMatrix
(2)ACpowercords
(1)QuickStartGuide
FEATURES
4
FRONT PANEL LAYOUT
Front Panel
2
5
3 41
GEFEN
32x32 DVI MATRIX
5
FRONT PANEL DESCRIPTIONS
Front Panel
1 ModeButtons
Thesebuttonsareusedtocontrolotherfeaturesontheproduct.Seepages11-25for
moreinformation.
2 OutputButtons(1-32)
UsedforroutinganInputtoanOutput.EachofthesebuttonsrepresentsanOutput.
Seepage11formoreinformationonroutingDVIsources.
3 PowerIndicator
ThisLEDindicatorwillglowredwhenthepoweristurnedon.
4 LCDDisplay
DisplaysthecurrentroutingstatusoftheMatrixandisalsousedtomanagesource
routing.
5 InputButtons(1-32)
UsedforroutinganInputtoanOutput.EachofthesebuttonsrepresentsanInput.
Seepage11formoreinformationonroutingDVIsources.
6
BACK PANEL LAYOUT
Back Panel
1
2
3
4
5
6 7
7
BACK PANEL DESCRIPTIONS
Back Panel
1 Out(1-32)
ConnectDVIdisplaystotheseports.
2 In(1-32)
ConnectcomputersorotherDVIsourcedevicestotheseports.
3 RS-232SerialPort
ConnectstotheRS-232controldevice.The32x32DVIMatrixmaybeswitchedremotely
usingthisport.Seepage26formoreinformation.
4 IP/TelnetControl
Connectthe32x32DVIMatrixtoanetworkinordertouseIP/Telnetcontrol.
5 IR
ConnectanIRextendertothisIRport.
6 Power
ThisLEDindicatorglowsbrightredwhenthematrixispoweredon.
7 PowerSupply(1-2)
ConnecttheincludedACpowercordsfromthesereceptacletoanavailableelectrical
outlet.Theredundant(secondary)powercableshouldbeconnectedtoanelectricaloutlet
onadifferentcircuit.Eachpowersupplyis110/220VAC.
8
DVI Displays
DVI CABLE
32x
DVI Sources
32x
Matrix
RS-232 CABLE
ETHERNET CABLE
EXT-DVI-32432
RS-232 Controller
IP Control
How to Connect the 32x32 DVI Matrix
1. Connectupto32DVIsourcedevicestotheDVIinputsontherearpanelofthe32x32
DVIMatrixusingDVIcables.
2. Connectupto32DVIdisplaystotheDVIoutputsontherearpanelofthe32x32DVI
Matrix.
3. Connecttheincludedpowercordtothepowerinputreceptacleontherearpanelof
the32x32DVIMatrix.Connecttheoppositeendofthecableintoaopenwallpower
socket.
Wiring Diagram for the GefenPRO 32x32 DVI Matrix
CONNECTING THE 32X32 DVI MATRIX
WARNING:Thisproductshouldalwaysbeconnectedtoa
groundedelectricalsocket.
9
Booting Up / Standby Screen
Thefront-panelLCDofthe32x32DVIMatrixisa16character2linedisplay.Thisdisplay
isusedtoaidinperformingroutingcommands,aswellasdisplayingadditionalsystem
information.Whentheunitispoweredon,thefollowingscreensaredisplayed:
Afterafewmoments,thestandbyscreenisdisplayed:
OPERATING THE 32X32 DVI MATRIX
EDID LOADING
PLEASE WAIT
EDID LOADING
COPY COMPLETED
GEFEN
32x32 DVI MATRIX
10
Displaying the Current Routing State
TodisplaythecurrentroutingstatusoftheMatrix,pressanyoneoftheInputorOutput
buttonsonthefrontpanel.
Intheexampleabove,InputA1isroutedtoOutputA4,OutputA5,OutputA7,OutputA8,
OutputB1,OutputB2,OutputB3,OutputC3,OutputC5,andOutputC6.Asourcedoes
notneedtobeconnectedtotheMatrixtodisplaythecurrentroutingstate.Bydefault,all
inputsareroutedtotheirrespectiveoutputs(e.g.A1-A1,A2-A2,C3-C3,D5-D5,etc).
OPERATING THE 32X32 DVI MATRIX
Outputbuttons
Inputbuttons
11
Routing Sources
1. Tochangethecurrentroutingstate,presstheSetbuttontoactivateRoutingMode.
Thefront-panelLCDwillindicatethatRoutingModehasbeenselected:
2. PressthedesiredOutputbutton(s)fromthetoptworowsofpush-buttons.Oneor
moreOutputbuttonsmaybeselected.
MODE BUTTONS
PresstheSetbutton
ROUTING MODE
12
MODE BUTTONS
3. SelectanyInputfromthebottomtworowsofbuttons(A1-D8),correspondingtothe
sourcetobedisplayedontheoutput(s).
4. PresstheSetbuttonagaintocompletetheoperation.
Thefront-panelLCDdisplaywillindicatethattheroutingprocessiscomplete:
PresstheSetbutton
ROUTING COMPLETE
13
MODE BUTTONS
System Lock Mode
LockingtheMatrixpreventschangestoanyoftheMatrixsettings.Thisfeatureisuseful
incaseanyofthefrontpanelbuttonsarepressedbyaccident.LockingtheMatrixalso
preventschangesusingtheIRRemoteControlUnit.
1. PresstheLockbuttontoactivateSystemLockMode.
Thefront-panelLCDscreenwilldisplaythefollowingwhileinSystemLockMode:
2. PresstheLockbuttonasecondtimetodeactivateSystemLockMode.
PresstheLockbutton
LOCK MODE
GEFEN
32x32 DVI MATRIX
14
Cancelling a Function
PresstheCancelbutton,whileinanymode,toreturntocancelthecurrentfunctionand
displaytheStandbyModescreen.
The32x32DVIMatrixfront-panelLCDscreenasitappearsinStandbymode:
MODE BUTTONS
Cancelbutton
GEFEN
32x32 DVI MATRIX
15
Cycling between Information Screens
PresstheCancelbuttonmorethanonce,whileinStandbyMode,tocyclethrougheachof
theinformationscreens:
MODE BUTTONS
PresstheCancelbutton
GEFEN
32x32 DVI MATRIX
IP ADDRESS
192.168.2.235
MAC ADDRESS
0.1C.91.2.80.0
FW 0.2
BOLO 0.0
GEFEN
32x32 DVI MA
16
MODE BUTTONS
Saving the current Routing State
1. Settheroutingstate(seepage11),thenpressthePreSetbuttontwice toactivate
PresetMode.
AfterpressingthePreSetbuttononce,thefollowingwillbedisplayedonthefront-
panelLCDscreen:
PressthePreSetbuttonagain.Thefollowingwillbedisplayedonthe
front-panelLCDscreen:
PressthePreSetbuttontwice
PRESET MODE
RECALL SAVED STATE
PRESET MODE
SAVE CURRENT SET
/