Danfoss NRV CO2 Installation guide

Type
Installation guide
Installation Guide
Check valve for high pressure
Type NRV 10s H
© Danfoss A/S (AC-MCI sw) 2013-04 DKRCC.PI.FE0.D2.02 / 520H7634 1
020R9504
020R9504
Refrigerant:
R744 (CO
2
)
Media temperature:
T
min
: -50 °C ( -58 °F)
T
max
: 140 °C (285 °F)
Max. working pressure:
PS/MWP = 90 bar (1305 psig)
Max. 660 °C / 1220 °F
Min. 5% Ag
Danfoss
R64-3000.10
When the NRV is used together with GBC in parallel as a pressure
relief valve, it is recommend to install the NRV above the GBC.