Comelit IPTHPAN02FA is a high-quality device that combines temperature measurement and face recognition capabilities. It's an excellent choice for various applications, including access control, time attendance, and health screening. Here are some of the critical features and possible use cases:

Key Features:

  • Accurate Temperature Measurement: Measures body temperature from a distance of 3-5 cm, providing fast and reliable temperature readings.
  • Facial Recognition: Uses advanced algorithms to recognize faces, allowing for touchless and secure access control.
  • Alarm System: Includes two-channel alarm input and output, enabling integration with external alarm systems for enhanced security.

Comelit IPTHPAN02FA is a high-quality device that combines temperature measurement and face recognition capabilities. It's an excellent choice for various applications, including access control, time attendance, and health screening. Here are some of the critical features and possible use cases:

Key Features:

  • Accurate Temperature Measurement: Measures body temperature from a distance of 3-5 cm, providing fast and reliable temperature readings.
  • Facial Recognition: Uses advanced algorithms to recognize faces, allowing for touchless and secure access control.
  • Alarm System: Includes two-channel alarm input and output, enabling integration with external alarm systems for enhanced security.
Temperature Measurement & Face
Recognition Terminal
Art. IPTHPAN02FA
Please read this manual thoroughly before use and keep it for future
reference
1 Package content
2 Overview
3 Cable connections
Terminal block description
1
2
3
4
5
6
7
8
9
NO2
COM2
NO1
COM1
NO3
COM3
NC3
D+
D-
2CH alarm output Lock interface RS 485
10
11
12
13
14
15
16
17
18
IN1
GND
IN2
GND
D0
D1
GND
BUT
GND
2CH alarm input Wiegand interface Exit button
Device
Quick Start Guide
Tapping Screw×4
Drill Template Plastic Plug ×4
White
light
IR light
161.8
271
Cameras
Display
Speaker
30.8
Wrist
mesurement
module
Micro-SD
card slot
Reset
USB port
Microphone
18-pin
interface
card slot
Power
supply
Note:
The Wiegand terminal is an input terminal. If you want to connect an access controller, you
shall set the Wiegand direction to “Output”.
The RS 485 interface of this device supports security access module. Once the security
module is enabled, the exit button and the lock control are disabled.
Power input
Alarm input 1
Alarm input 2
Alarm output 1
Alarm output 2
RS485
Wiegand interface
Lock
Exit button
Ethernet
Power input
Alarm input 1
Alarm input 2
Alarm output 1
Alarm output 2
RS485
Wiegand
interface
Lock
Exit button
+12V
Earth
GND
Alarm Input Device
Alarm Input Device
Alarm Output Device
Alarm Output Device
Access Control Security Module
RS485+
RS485-
Ethernet
Router
or
Switch
D0
D1
GND
Card
reader
Power
+
Anode/
Magnetic
Lock
-
+
Power
-
-
Cathode
Lock
+
Exit
button
4 Installation
Ambient illumination requirement
Make sure that the faces can be captured clearly.
Avoid direct sunlight and backlight
The device should be at least 2 meters away from the light, and at least 3
meters away from windows or doors
Installation
Height requirement
Paste the drill template
onto the wall and
then drill
the holes according to it.
Use two screws to secure the
bracket on the gang box.
Secure the bracket onto the wall
with 4 screws.
Route and connect the cables,
then install the cable cover
Hang the device onto the
bracket hook and
then tighten the screws.
The recommended installation height
(H) is 1.3 ÷ 1.45m which can cover
human height of 1.4 ÷ 1.9m in the
detection area.
The face recognition distance ranges
is 0.3 ÷ 0.4m.
The best temperature measuring
distance for the wrist is 3-5cm.
Available accessories (optional)
BRKPAN - Swivel backplate
BRKPAN-LA - Floor mounting backplate
BRKPAN-WM - Wall mounting backplate
BRKPAN-SA - Desk base
5 Network
Make sure that the device and the PC are connected via LAN
Install the software Comelit Advance IP Tool and run it as shown
below:
Modify the IP address. The default IP address is 192.168.1.150. Click the
information of the camera listed in the above table to show the network
information on the right hand.
Modify the IP address and gateway of the camera and make sure that its
network address is in the same local network segment of the computer.
After modification, please enter the password of the administrator and click
“Modify” button to modify the settings.
The default Password of the administrator is admin.
Double-click on the device listed in the Comelit Advance IP Tool or
manually enter the IP address in the address bar of Internet Explorer
browser to connect it. Follow the instructions to download and install the
plugin.
Enter the Username and the Password in the login interface.
The default Username is admin; the default Password is admin.
The default network settings are shown below:
IP address: 192.168.1.150
Subnet Mask: 255.255.255.0
Gateway: 192.168.1.1
HTTP: 80
Data port: 9008
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Comelit IPTHPAN02FA User manual

Category
Wall & ceiling mounts accessories
Type
User manual

Comelit IPTHPAN02FA is a high-quality device that combines temperature measurement and face recognition capabilities. It's an excellent choice for various applications, including access control, time attendance, and health screening. Here are some of the critical features and possible use cases:

Key Features:

  • Accurate Temperature Measurement: Measures body temperature from a distance of 3-5 cm, providing fast and reliable temperature readings.
  • Facial Recognition: Uses advanced algorithms to recognize faces, allowing for touchless and secure access control.
  • Alarm System: Includes two-channel alarm input and output, enabling integration with external alarm systems for enhanced security.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI