BRAVILOR BONAMAT RLX 41 Owner's manual

Type
Owner's manual

This manual is also suitable for

GB
Bravilor Bonamat
RLX
HOTWATER/STEAM MODULE
700.403.277
Bravilor Bonamat
122001
Bravilor Bonamat
Pascalstraat 20
1704 RD Heerhugowaard
The Netherlands
Table of contents
GB
version 1.0 ECopyright Bravilor Bonamat B.V.
II
1. Modules 4 and 8 (hot water/steam) 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.1 Introduction 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.1.1 General description 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.1.2 Main components 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.2 Technical data 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.3 First use 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.3.1 Flushing 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.4 Daily use 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.4.1 Controls 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.4.2 Operation 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.4.2.1 Preparing steam 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.4.2.2 Tapping hot water 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.4.2.3 Heating with steam 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.5 Programming the module 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.6 Maintenance 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.6.1 General 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.6.2 Regular cleaning of the steam outlet 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.6.3 Descaling 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.7 Correcting malfunctions 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.7.1 Troubleshooting hotwater module 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.7.2 Error messages 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GB
version 1.0ECopyright Bravilor Bonamat B.V.
1
1. MODULES 4 AND 8 (HOT WATER/STEAM)
1.1 Introduction
In this document, the specific information for
the abovementioned module is discussed.
Please also thoroughly read the general user
instructions.
1.1.1 General description
These modules are designed for the preparation
of hot water and steam. The water is heated and
the boiler is brought up to pressure as soon as
the module is switched on using the ON/OFF
switch. The water is drawn off using the
hotwater drawoff tap. Drinks may be heated up
by steam, using the steamdrawoff tap.
1.1.2 Main components
1
2
3
1
2
5
4
Fig. 1 Main components hotwater/steam modules
1. ON/OFF switch
2. operating panel
3. steam tap
4. hotwater tap
5. outlet safety valve
1.2 Technical data
D See table 1 for additional technical information
about the steam modules.
Modules 4 and 8
Boiler capacity 22,5 litre
hourly capacity 24,6 litre
water reserve 21,6 litre
overpressure (steam pressure) 20,6 bar
Table 1 Technical information
1.3 First use
1.3.1 Flushing
1. Switch on the module.
The module will first take water to the
maximum level, after which the pressure is
brought up to 0.6 bar.
2. Drain off the water using the hot water
drawoff tap.
After this, the steam module is ready for use.
1.4 Daily use
1.4.1 Controls
A
B
C
D
Fig. 2 Control panel hotwater/steam modules
A. descaling indication
Will flash to show that the machine needs to
be descaled.
B. [] button
Push button to change the values during
programming.
C. [+] button
Push button to change the values during
programming.
D. Display
Displays the overpressure.
GB
version ECopyright Bravilor Bonamat B.V.2 1.0
1.4.2 Operation
1.4.2.1 Preparing steam
1. Switch on the module.
The boiler is filled and the water is heated
up.
During the filling and the heating process,
the display shows little marks that are
turning around.
2. Wait until the display indicates the pressure of
the steam.
The module is now ready to heat up drinks using
steam.
1.4.2.2 Tapping hot water
1. Place a cup or a jug under the hot water tap.
2. Open the tap.
3. Turn off the tap as soon as sufficient water
has been drawn off.
WARNING
n If all the water is drawn from the boiler, it may
come spluttering out until finally only
condensation comes out of the drawoff tap.
1.4.2.3 Heating with steam
1. Place the container with the drink to be
heated underneath the steamdrawoff tap.
2. Make sure to insert the steam outlet a couple
of centimetres into the liquid.
3. Open the tap gradually.
The drink will now be heated by the steam
that is passed through the liquid under
pressure.
4. Turn off the tap as soon as the drink has
reached the desired temperature.
5. Remove the container with the drink.
6. Draw off a little more steam to ensure that
any of the drink that remains behind in the
outlet is removed.
TIP
Clean the steam outlet regularly to ensure
that the flavour of the heated drink is not
affected.
WARNING
n Never touch the steam outlet.
1.5 Programming the
module
The operating panel is also used for programming
purposes.
During programming, the [] button (B.) serves to
lower certain values, and the [+] button (C.) to
raise them.
P1 (counter position descaling):
Setting the counter position, at which the
descaling signal is to start flashing.
P2 (total):
Reading the total number of litres of water that
has run through the module.
Factory setting Set by you
P1 3
1. Simultaneously press the [+] button (C.) and
the [] button (B.) to start the programming
mode.
2. Keep them pressed for about 10 seconds,
until P1 appears on the display.
3. Let go of the buttons.
The value for P1 appears.
4. Adjust, if desired, the value.
5. Press both buttons again for a short moment
to select the next P values.
6. Wait for about 60 seconds.
The programming mode will automatically
be switched off, storing the set value.
GB
version 1.0ECopyright Bravilor Bonamat B.V.
3
1.6 Maintenance
1.6.1 General
D See §1.5 of the General user instructions.
1.6.2 Regular cleaning of the
steam outlet
1. Unscrew the steam outlet from the steam tap.
2. Clean the steam outlet with a brush under
running water.
3. If any of the holes are blocked, prick them
until they are open again.
1.6.3 Descaling
Specialist knowledge is required when
descaling the steam module. Have your
service technician do this!
1.7 Correcting malfunctions
D See §1.6.1 of the General user instructions.
1.7.1 Malfunctioning analysis hotwater/steam module
LIST OF MALFUNCTIONS
Symptom: Possible cause: Actions:
1. [ ] Stays turning in the
display.
The module is not (yet) on
pressure.
Wait until the modul is on
pressure (ca. 10 min.).
Reset boil dry device.
2. When using the steamtap,
water comes out instead of
steam.
Replace magnetic valve.
3. Descaling signal is flashing. Descaling counter has reached
the maximum number of litres.
Descale the hot water/steam
modules.
4. Water drips out of outlet
safety valve.
Check valve on scale.
1.7.2 Display messages
DISPLAY MESSAGES
Possible cause: Actions:
E1 The overflow protection was activated. Check the supply hose for any kinks.
Check the water pressure at the same time.
Reset the system afterwards: set the
ON/OFF switch to the off position and then
switch it on again.
Call in service.
GB
version ECopyright Bravilor Bonamat B.V.4 1.0
Notes
FR
Bravilor Bonamat
RLX
MODULE EAU CHAUDE/VAPEUR
700.403.277
Bravilor Bonamat
122001
Bravilor Bonamat
Pascalstraat 20
1704 RD Heerhugowaard
Pays Bas
FR
version ECopyright Bravilor Bonamat B.V.4 1.0
Notes
DE
Version ECopyright Bravilor Bonamat B.V.4 1.0
Notizen
NL
Bravilor Bonamat
RLX
HEETWATER/STOOM MODULE
700.403.277
Bravilor Bonamat
122001
Bravilor Bonamat
Pascalstraat 20
1704 RD Heerhugowaard
Nederland
NL
versie ECopyright Bravilor Bonamat B.V.4 1.0
Notities
SE
version ECopyright Bravilor Bonamat B.V.4 1.0
Notiser
NO
versjon
ECopyright Bravilor Bonamat B.V.4 1.0
Notater
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38

BRAVILOR BONAMAT RLX 41 Owner's manual

Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI