SICK Flexi Compact Safety controller Operating instructions

Type
Operating instructions
O P E R A T I N G I N S T R U C T I O N S
Flexi Compact
Safety controller
Described product
F
lexi Compact
Manufacturer
SICK AG
Erwin-Sick-Str. 1
79183 Waldkirch
Germany
Legal information
T
his work is protected by copyright. Any rights derived from the copyright shall be
reserved for SICK AG. Reproduction of this document or parts of this document is
only permissible within the limits of the legal determination of Copyright Law. Any modi‐
fication, abridgment or translation of this document is prohibited without the express
written permission of SICK AG.
The trademarks stated in this document are the property of their respective owner.
© SICK AG. All rights reserved.
Original document
T
his document is an original document of SICK AG.
EtherCA
EtherCAT® and Safety over EtherCAT® are registered trademarks and patented tech‐
nologies, licensed by Beckhoff Automation GmbH, Germany.
The backplane bus is based on EtherCAT® and Safety over EtherCAT®.
2
O P E R A T I N G I N S T R U C T I O N S | Flexi Compact 8024589/2020-11-10 | SICK
Subject to change without notice
Contents
1 About this document........................................................................ 6
1.1 Purpose of this document........................................................................ 6
1.2 Scope......................................................................................................... 6
1.3 Target groups and structure of these operating instructions................ 6
1.4 Further information................................................................................... 7
1.5 Symbols and document conventions...................................................... 7
2 Safety information............................................................................ 9
2.1 General safety notes................................................................................ 9
2.2 Intended use............................................................................................. 9
2.3 Improper use............................................................................................. 9
2.4 Requirements for the qualification of personnel.................................... 9
3 Product description........................................................................... 11
3.1 Configuration of the safety controller...................................................... 11
3.2 Overview of the module............................................................................ 12
3.3 Configuration and function...................................................................... 13
3.4 Status indicators....................................................................................... 14
3.5 Interfaces.................................................................................................. 15
3.5.1 SmartPlug................................................................................. 15
3.5.2 TCP/IP configuration interface (CPUc2)................................. 15
4 Project planning................................................................................ 17
4.1 Manufacturer of the machine.................................................................. 17
4.2 Operating entity of the machine.............................................................. 17
4.3 Design........................................................................................................ 17
4.4 Muting application.................................................................................... 18
4.4.1 Safety notes for muting applications...................................... 18
4.4.2 Overview and general description.......................................... 21
4.4.3 Notes on wiring........................................................................ 26
4.5 Electrical integration................................................................................. 27
4.5.1 Internal circuitry....................................................................... 27
4.5.2 Fault detection using test outputs.......................................... 27
4.5.3 Safety outputs.......................................................................... 28
4.6 Integration into the controller network.................................................... 28
4.6.1 Network topology..................................................................... 28
4.6.2 Integration via the fieldbus interface..................................... 29
4.7 Testing plan............................................................................................... 29
5 Mounting............................................................................................. 30
5.1 Safety......................................................................................................... 30
5.2 Mounting procedure................................................................................. 30
5.3 Mounting the SmartPlug in the main module......................................... 32
5.4 Disassembly.............................................................................................. 33
CONTENTS
8024589/2020-11-10 | SICK O P E R A T I N G I N S T R U C T I O N S | Flexi Compact
3
Subject to change without notice
5.5 Module exchange...................................................................................... 33
6 Electrical installation........................................................................ 35
6.1 Safety......................................................................................................... 35
6.2 Device connection.................................................................................... 35
6.3 Coding........................................................................................................ 37
6.3.1 Coding front connector and module....................................... 38
7 Configuration..................................................................................... 40
7.1 Safety Designer configuration software.................................................. 40
7.1.1 User interface.......................................................................... 40
7.1.2 User groups.............................................................................. 40
7.2 Offline, online and security configuration............................................... 41
7.3 Overview main na
vigation menu................................................................ 43
7.4 Configuration main navigation menu......................................................... 43
7.4.1 Configuring the general settings............................................. 44
7.4.2 Specifying the device identification attributes...................... 44
7.4.3 Protecting the configuration in the SmartPlug with a pass‐
word.......................................................................................... 45
7.4.4 Adding expansion modules..................................................... 45
7.4.5 Input elements......................................................................... 45
7.4.6 Output elements...................................................................... 48
7.4.7 Adding, configuring and expanding elements........................ 50
7.4.8 Creating customized elements............................................... 51
7.4.9 Exporting and importing the module configuration............... 52
7.4.10 Tag name editor....................................................................... 53
7.5 Configuring the network interfaces......................................................... 54
7.5.1 Configuring Modbus connections........................................... 54
7.5.2 Configuring SLMP connections............................................... 54
7.5.3 Configuring the output data (routing to CPU)......................... 54
7.5.4 Configuring the input data (routing to network)..................... 55
7.6 Logic editor main navigation.................................................................... 55
7.6.1 Inputs........................................................................................ 56
7.6.2 Function blocks........................................................................ 57
7.6.3 Outputs..................................................................................... 105
7.6.4 Diagnostics............................................................................... 106
7.6.5 CPU marker.............................................................................. 107
7.6.6 Jump addresses....................................................................... 107
7.6.7 Logic programming in the logic editor.................................... 107
7.6.8 Logic execution time................................................................ 109
7.6.9 I/O matrix................................................................................. 109
7.6.10 I/O summary page................................................................... 109
7.6.11 Logic access protection........................................................... 109
7.7 Report main navigation menu................................................................. 112
7.8 Service main navigation menu................................................................ 112
7.9 Establishing a connection........................................................................ 112
CONTENTS
4
O P E R A T I N G I N S T R U C T I O N S | Flexi Compact 8024589/2020-11-10 | SICK
Subject to change without notice
7.10 Transferring the configuration.................................................................. 112
7.11 Verification................................................................................................ 113
7.11.1 Verifying the configuration content and configuration
t
ransfer at the same time....................................................... 114
7.12 Checksums................................................................................................ 114
7.13 Testing safety functions............................................................................ 115
8 Commissioning.................................................................................. 116
8.1 Check during commissioning and modifications.................................... 116
9 Operation............................................................................................ 117
9.1 Regular thorough check........................................................................... 117
10 Maintenance...................................................................................... 118
10.1 Regular thorough check........................................................................... 118
11 Troubleshooting................................................................................. 119
11.1 Status indicators....................................................................................... 119
11.2 Possible faults........................................................................................... 121
11.3 Diagnostics using Safety Designer.......................................................... 124
11.3.1 Error history.............................................................................. 124
12 Decommissioning............................................................................. 125
12.1 Disposal..................................................................................................... 125
13 Technical data.................................................................................... 126
13.1 Data sheet................................................................................................. 126
13.2 Maximum response time.......................................................................... 131
13.2.1 Calculating the response time................................................ 132
13.2.2 Example response time calculation........................................ 135
13.3 Data exchange in the network................................................................. 138
13.3.1 Modbus® TCP.......................................................................... 138
13.3.2 SLMP........................................................................................ 143
13.4 Dimensional drawings.............................................................................. 146
14 Ordering information........................................................................ 147
14.1 Scope of delivery....................................................................................... 147
14.2 Ordering information for main module.................................................... 147
14.3 Ordering information for expansion module........................................... 147
14.4 Ordering information for accessories...................................................... 147
15 Annex.................................................................................................. 149
15.1 Compliance with EU directives................................................................. 149
16 List of figures..................................................................................... 150
17 List of tables....................................................................................... 151
CONTENTS
8024589/2020-11-10 | SICK O P E R A T I N G I N S T R U C T I O N S | Flexi Compact
5
Subject to change without notice
1 About this document
1.1 Purpose of this document
These operating instructions contain the information required during the life cycle of the
s
afety controller.
Operating instructions of the safety controller must be made available to all people who
work with the device.
1.2 Scope
These operating instructions apply to the Flexi Compact safety controller.
T
his document is included with the following SICK part numbers (this document in all
available language versions):
8024573
Furthermore, the following documents contain information about the safety controller:
T
able 1: Available documents
Document Title Part number
Operating instructions FLX3-XTDI1 expansion module
f
or safety controllers
8024571
Operating instructions FLX3-XTDO1 expansion mod‐
ule for safety controllers
8024570
Operating instructions FLX0-GPNT1 expansion mod‐
ule f
or safety controllers
8024567
Operating instructions FLX0-GETC1 expansion mod‐
ule for safety controllers
8024566
Operating instructions Flexi Loop Safe Series Con‐
nection Hardware
8015834
Operating instructions Flexi Loop in the Safety
D
esigner Software
8018174
Competence brochure Guide for Safe Machinery 8008007
1.3 Target groups and structure of these operating instructions
These operating instructions are intended for the following target groups: project devel‐
oper
s (planners, developers, designers), installers, electricians, safety experts (such as
CE authorized representatives, compliance officers, people who test and approve the
application), operators, and maintenance personnel.
These operating instructions are organized by the life phases of the device: project
planning, mounting, electrical installation, commissioning, operation and maintenance.
The table below shows the target groups and how – for many applications – these are
typically divided up between the manufacturer and the entity operating the machine in
which the device is to be integrated:
1 A
BOUT THIS DOCUMENT
6
O P E R A T I N G I N S T R U C T I O N S | Flexi Compact 8024589/2020-11-10 | SICK
Subject to change without notice
Area of responsibility Target group Specific chapters of these operating instruc‐
t
ions
1)
Manufacturer Project developers
(planners, developers,
designers)
Project planning, page 17
Technical data, page 126
Installers Mounting, pa
ge 30
Electricians Electrical installation, page 35
Safety experts Project planning, pa
ge 17
Commissioning, page 116
Technical data, page 126
Operating entity Operators Troubleshooting, pa
ge 119
Maintenance staff Troubleshooting, page 119
Ordering information, page 147
1)
Chapters not listed here are intended for all target groups. All target groups must follow all of the safety
and warning instructions in all chapters of the operating instructions!
In other applications, the operating organization is also the manufacturer of the equip‐
ment w
ith the corresponding allocation of the target groups.
1.4 Further information
www.sick.com
T
he following information is available via the Internet:
This document in other languages
Data sheets and application examples
CAD files and dimensional drawings
Certificates (such as the EU declaration of conformity)
Guide for Safe Machinery. Six steps to a safe machine
Safety Designer (software for configuring safety solutions made by SICK AG)
1.5 Symbols and document conventions
The following symbols and conventions are used in this document:
Safety notes and other notes
DANGER
Indicates a situation presenting imminent danger, which will lead to death or serious
injuries if not prevented.
WARNING
Indic
ates a situation presenting possible danger, which may lead to death or serious
injuries if not prevented.
CAUTION
Indic
ates a situation presenting possible danger, which may lead to moderate or minor
injuries if not prevented.
NOTICE
Indic
ates a situation presenting possible danger, which may lead to property damage if
not prevented.
ABOUT THIS DOCUMENT 1
8024589/2020-11-10 | SICK O P E R A T I N G I N S T R U C T I O N S | Flexi Compact
7
Subject to change without notice
NOTE
Indic
ates useful tips and recommendations.
Instructions to action
b
T
he arrow denotes instructions to action.
1. The sequence of instructions for action is numbered.
2. Follow the order in which the numbered instructions are given.
The check mark denotes the result of an instruction.
1 A
BOUT THIS DOCUMENT
8
O P E R A T I N G I N S T R U C T I O N S | Flexi Compact 8024589/2020-11-10 | SICK
Subject to change without notice
2 Safety information
2.1 General safety notes
This chapter contains general safety information about the safety controller.
F
urther safety information is provided in the respective chapters to cover the specific
situations in which the product may be used.
DANGER
If t
he device is not integrated in the way intended by the manufacturer, the protective
function of the device can be impaired. The dangerous state may be ended too late.
b
Plan the integration of the safety component in accordance with the machine
requirements, see "Project planning", page 17.
2.2 Intended use
The Flexi Compact safety controller is a freely configurable control for safety applica‐
t
ions. Sensors and switching elements (e.g. light curtains, laser scanners, switches,
sensors, encoders, emergency stop pushbuttons) are connected to the safety controller
and are linked logically. The corresponding actuators of the machines or systems can
be switched off safely via the switching outputs of the safety controller.
Incorrect use, improper modification or manipulation of the module will invalidate any
warranty from SICK; in addition, any responsibility and liability of SICK AG for damage
and secondary damage caused by this is excluded.
The safety controller system is only suitable for use in industrial environments.
2.3 Improper use
Among others, the safety controller is not suitable for the following applications:
Out
doors
Underwater
In explosion-hazardous areas
In residential areas
2.4 Requirements for the qualification of personnel
The protective device must be configured, installed, connected, commissioned, and
ser
viced by qualified safety personnel only.
Project planning
For project planning, a person is considered competent when he/she has expertise and
experience in the selection and use of protective devices on machines and is familiar
with the relevant technical rules and national work safety regulations.
Mechanical mounting, electrical installation, and commissioning
F
or the task, a person is considered qualified when he/she has the expertise and
experience in the relevant field and is sufficiently familiar with the application of the
protective device on the machine to be able to assess whether it is in an operationally
safe state.
SAFETY INFORMATION 2
8024589/2020-11-10 | SICK O P E R A T I N G I N S T R U C T I O N S | Flexi Compact
9
Subject to change without notice
Operation and maintenance
F
or operation and maintenance, a person is considered competent when he/she has
the expertise and experience in the relevant field and is sufficiently familiar with the
application of the protective device on the machine and has been instructed by the
machine operator in its operation.
2 S
AFETY INFORMATION
10
O P E R A T I N G I N S T R U C T I O N S | Flexi Compact 8024589/2020-11-10 | SICK
Subject to change without notice
3 Product description
3.1 Configuration of the safety controller
Configuration of the safety controller
A s
afety controller comprises the following components:
A main module
Up to 12 optional expansion modules (excluding maximum 1 gateway)
I3
I5
Q1
Q7
I4
I6
Q2
Q8
A2
I7
Q3
Q5
A1
I8
Q4
Q6
I2
PWR
I1
I3
I5
Q1
Q7
I4
I6
Q2
Q8
A2
I7
Q3
Q5
A1
I8
Q4
Q6
I2
PWR
I1
I3
I5
Q1
Q7
I4
I6
Q2
Q8
A2
I7
Q3
Q5
A1
I8
Q4
Q6
I2
PWR
I1
I3
I5
Q1
Q7
I4
I6
Q2
Q8
A2
I7
Q3
Q5
A1
I8
Q4
Q6
I2
PWR
I1
I3
I5
Q1
Q7
I4
I6
Q2
Q8
A2
I7
Q3
Q5
A1
I8
Q4
Q6
I2
PWR
I1
I3
I5
Q1
Q7
I4
I6
Q2
Q8
A2
I7
Q3
Q5
A1
I8
Q4
Q6
I2
PWR
I1
I3
I5
Q1
Q7
I4
I6
Q2
Q8
A2
I7
Q3
Q5
A1
I8
Q4
Q6
I2
PWR
I1
I3
I5
Q1
Q7
I4
I6
Q2
Q8
A2
I7
Q3
Q5
A1
I8
Q4
Q6
I2
PWR
I1
I3
I5
Q1
Q7
I4
I6
Q2
Q8
A2
I7
Q3
Q5
A1
I8
Q4
Q6
I2
PWR
I1
I3
I5
Q1
Q7
I4
I6
Q2
Q8
A2
I7
Q3
Q5
A1
I8
Q4
Q6
I2
PWR
I1
I3
I5
Q1
Q7
I4
I6
Q2
Q8
A2
I7
Q3
Q5
A1
I8
Q4
Q6
I2
PWR
I1
1
2
3
FLEXIcompact
CV
I1
I3
I7
X1
I2
I4
I8
X
2
X
4
I5
I9
I11
X3
I6
I10
I12
I15
I17
X5
Q3
I16
I18
X6
Q4
A2
I19
X7
Q1
A1
I20
X8
Q2
I14
PWR
I13
Figure 1: Example maximum configuration
1
Main module
2
Expansion module - gateway
3
IO expansion module
Complementary information
The gateway and IO expansion modules can be arranged arbitrarily.
PRODUCT DESCRIPTION 3
8024589/2020-11-10 | SICK O P E R A T I N G I N S T R U C T I O N S | Flexi Compact
11
Subject to change without notice
3.2 Overview of the module
FLEXIcompact
1
2
3
4
5
CV
I1
I3
I7
X1
I2
I4
I8
X
2
X
4
I5
I9
I11
X3
I6
I10
I12
I15
I17
X5
Q3
I16
I18
X6
Q4
A2
I19
X7
Q1
A1
I20
X8
Q2
I14
PWR
I13
Figure 2: FLX3-CPUC1 module
1
Release elements of the module
2
Status indicators (LEDs)
3
Release elements of the front connector
4
SmartPlug with USB connection
5
Front connector with terminals (spring type)
1
2
3
4
5
6
FLEXIcompact
CV
I1
I3
I7
X1
I2
I4
I8
X
2
X
4
I5
I9
I11
X3
I6
I10
I12
I15
I17
X5
Q3
I16
I18
X6
Q4
A2
I19
X7
Q1
A1
I20
X8
Q2
I14
PWR
I13
Figure 3: FLX3-CPUC2 module
1
Release elements of the module
2
Status indicators (LEDs)
3
Release elements of the front connector
3 PRODUCT DESCRIPTION
12
O P E R A T I N G I N S T R U C T I O N S | Flexi Compact 8024589/2020-11-10 | SICK
Subject to change without notice
4
SmartPlug with USB connection
5
Front connector with terminals (spring type)
6
RJ45 female Ethernet connector
3.3 Configuration and function
Configuration
T
able 2: Interfaces of the module
Description Quantity
Safety capable inputs 20
Safety capable outputs 4
Test outputs
1)
8
RJ45 female connector CPUc1: 0
CP
Uc2: 1
SmartPlug 1
1)
The test outputs can also be used to switch non-safety elements (e.g., lamps).
Function
T
he main module is the central processing unit of the modular safety controller. All
incoming signals are monitored and logically processed in the main module. The out‐
puts are switched based on this processing.
If the main module is used in conjunction with expansion modules, the communication
with the expansion modules is via the backplane bus.
The module offers the following functions:
Monitoring of the connected safety devices
Switching of the connected safety devices
Testing of the connected safety devices and the wiring (short-circuit detection)
Use of the test outputs as non-safe outputs
Programmable logic (binary logic, integer processing, application-specific function
blocks)
CPUc2: Ethernet interface as a TCP/IP configuration interface and data exchange
via Modbus® TCP and SLMP
Special IO functions (e.g., fast shut off)
Flexi Loop safe series connection
Complementary information
Eac
h test output has an independent test pulse generator. This enables differ‐
ent test pulse parameters to be selected and short-circuits in the wiring to be
detected.
The element connected to the output during hardware configuration determines
how the test output will be used. If the test output is used for a non-safety element
(e.g., a lamp), then the test pulse is switched off for the output.
Safety outputs have test pulses for detecting short-circuits in the wiring.
PRODUCT DESCRIPTION 3
8024589/2020-11-10 | SICK O P E R A T I N G I N S T R U C T I O N S | Flexi Compact
13
Subject to change without notice
3.4 Status indicators
Status indicators
FLEXIcompact
CV
I1
I3
I7
X1
I2
I4
I8
X
2
X
4
I5
I9
I11
X3
I6
I10
I12
I15
I17
X5
Q3
I16
I18
X6
Q4
A2
I19
X7
Q1
A1
I20
X8
Q2
I14
PWR
I13
CPUc1
1085349
FLEXIcompact
I13
I15
I17
X5
Q3
I16
I18
X6
Q4
A2A1
I19
X7
Q1 Q2
X8
I20
I14
PWR
I1
I3
I7
X1
I2
I4
I8
X2
X4X3
I5
I9
I11 I12
I10
I6
CV
FLEXIcompact
CV
I1
I3
I7
X1
I2
I4
I8
X
2
X
4
I5
I9
I11
X3
I6
I10
I12
I15
I17
X5
Q3
I16
I18
X6
Q4
A2
I19
X7
Q1
A1
I20
X8
Q2
I14
PWR
I13
CPUc2
1085351
FLEXIcompact
I13
I15
I17
X5
Q3
I16
I18
X6
Q4
A2A1
I19
X7
Q1 Q2
X8
I20
I14
PWR
I1
I3
I7
X1
I2
I4
I8
X2
X4X3
I5
I9
I11 I12
I10
I6
CV
Figure 4: LEDs for indicating the status
T
he arrangement of the status indicators corresponds to the arrangement of the termi‐
nals.
Status indicator
T
able 3: Status indicator
Labeling Color Function
PWR Green/Red Device status
CV Yellow Device configuration status
I1 … I20 Green Safety capable input 1 … 20
X1 … X8 Green Test output 1 … 8
Q1 … Q4 Green Safety capable output 1 … 4
3 PRODUCT DESCRIPTION
14
O P E R A T I N G I N S T R U C T I O N S | Flexi Compact 8024589/2020-11-10 | SICK
Subject to change without notice
Further topics
"T
roubleshooting", page 119
3.5 Interfaces
3.5.1 SmartPlug
SmartPlug
T
he SmartPlug is the system memory plug of the safety controller.
When installed, the SmartPlug is located behind the front connector of the main mod‐
ule. The SmartPlug has a USB connection for connecting the safety controller to a
computer.
The safety controller can only be operated when a SmartPlug is plugged in. The front
connector with the SmartPlug must only be removed when there is no power to the sys‐
tem. The safety controller stops program execution immediately if the front connector
with the SmartPlug is removed.
1 2
1
Figure 5: SmartPlug
1
Micro-USB connection
The SmartPlug performs the following functions:
T
ransferring the configuration from the configuration software into the system
plug.
Importing the configuration from the system plug into the configuration software.
When the module is replaced, the safety controller needs to be reconfigured.
The stored data are also retained in the event of an interruption to the voltage
supply.
Complementary information
If you use a display (e.g., on a gateway) to configure settings on the safety controller
that can also be configured using the configuration software, the configuration in the
SmartPlug is updated accordingly.
Further topics
"Mounting the SmartPlug in the main module", page 32
"Ordering information for accessories", page 147
3.5.2 TCP/IP configuration interface (CPUc2)
Important information
NOTE
T
he IP address must be assigned initially via the configuration software.
PRODUCT DESCRIPTION 3
8024589/2020-11-10 | SICK O P E R A T I N G I N S T R U C T I O N S | Flexi Compact
15
Subject to change without notice
TCP/IP configuration interface (CPUc2)
Y
ou can carry out the following functions over Ethernet via the TCP/IP configuration
interface of the CPUc2:
Transferring the configuration
Reading the configuration from the safety controller
Diagnostics
3 P
RODUCT DESCRIPTION
16
O P E R A T I N G I N S T R U C T I O N S | Flexi Compact 8024589/2020-11-10 | SICK
Subject to change without notice
4 Project planning
4.1 Manufacturer of the machine
DANGER
F
ailure to comply with manufacturer’s obligations
Hazard due to lack of effectiveness of the protective device
b
Carry out a risk assessment before using the safety controller.
b
Do not manipulate, open or modify the components of the safety controller.
b
Make sure the safety controller is only repaired by the manufacturer or by some‐
one authorized by the manufacturer. Improper repair can lead to a loss of the
protective function.
4.2 Operating entity of the machine
DANGER
F
ailure to observe operator obligations
Hazard due to lack of effectiveness of the protective device
b
Changes to the machine and changes to the hardware or the logic programming
of the safety controller necessitate a new risk assessment. The results of this risk
assessment may require the entity operating the machine to meet the obligations
of a manufacturer.
b
Apart from the procedures described in this document, the components of the
safety controller must not be opened or modified.
b
Do not carry out any repair work on components. Improper repair of the safety
controller can lead to a loss of the protective function.
4.3 Design
Mounting
Environment meets the requirements of IP54 or higher, e.g., IP54 control cabinet.
Mounting on a 35 mm × 7.5 mm mounting rail in accordance with IEC 60715.
The mounting rail is connected to the functional earth.
Mounting rail is mounted on a mounting plate.
Mounting plate is connected to functional earth.
Mounting in a vertical orientation (on a horizontal mounting rail).
Take suitable ESD protection measures.
Air circulation
To ensure sufficient air circulation and cooling, sufficient distance must be kept in the
control cabinet above and below the module.
Provide an adequate clearance in front of the module (front side) for the connected
cables.
PROJECT PLANNING 4
8024589/2020-11-10 | SICK O P E R A T I N G I N S T R U C T I O N S | Flexi Compact
17
Subject to change without notice
Figure 6: Clearances for adequate air circulation
R
equired distance:
Above and below the module: ≥ 30 mm
In front of the module: ≥ 25 mm
4.4 Muting application
4.4.1 Safety notes for muting applications
The safety functions of a protective device are bypassed by muting.
WARNING
R
estricted safety through muting
The dangerous state may not be stopped or not be stopped in a timely manner in the
event of non-compliance.
b
Observe the general safety specifications and protective measures.
b
You must always observe the following notes about how to use the muting function
correctly.
General safety notes for muting
b
Al
ways observe the national, regional, and local regulations and standards that are
applicable to the application.
b
Make sure that the application is in line with an appropriate risk analysis and risk
avoidance strategy.
b
Muting must be setup to be carried out automatically but not be dependent on a
single electrical signal.
b
Never use muting to transport a person into the hazardous area.
b
Make sure that muting is only activated for as long as access to the hazardous
area remains blocked by the object responsible for triggering the muting condition.
b
Make sure that the muting condition is terminated as soon as the object has
finished passing through so that the protective device returns to its standard
non-bypassed status (i.e., it must be reactivated).
4 P
ROJECT PLANNING
18
O P E R A T I N G I N S T R U C T I O N S | Flexi Compact 8024589/2020-11-10 | SICK
Subject to change without notice
b
In t
he case of long muting cycles (i.e., those lasting more than 24 hours) or long
machine downtimes, check the muting sensors to make sure they are functioning
correctly.
b
If the total muting time is set to infinite (inactive), use additional measures to
prevent anyone from entering the hazardous area while muting is active.
b
If safety-related information (i.e., remote safety capable input values and/or
remote safety output values) is transmitted via a safety fieldbus network, always
take the associated delay times into account. These delay times may influence
both the system behavior and the minimum safety distance requirements associ‐
ated with the response times.
Safety notes for the electro-sensitive protective equipment (ESPE)
b
A
ccess to the hazardous area must be reliably detected by the ESPE or other
measures must be taken to prevent a person from bypassing, exceeding, crawling
under or crossing the ESPE undetected.
b
Observe the operating instructions for the electro-sensitive protective device that
explain how to install and use the device correctly.
b
Secure the area between the electro-sensitive protective device and the muting
sensors as follows to prevent anyone standing behind:
°
With parallel muting – between the electro-sensitive protective device and
sensors A1 / A2 as well as between the electro-sensitive protective device
and sensors B1 / B2 (see figure 12, page 23).
°
With sequential muting – between the electro-sensitive protective device and
sensor A2 as well as between the electro-sensitive protective device and
sensor B1 (see figure 13, page 24).
°
With cross muting – between the electro-sensitive protective equipment and
sensor A1 as well as between the electro-sensitive protective equipment and
sensor A2 (see figure 14, page 25).
Safety notes for the muting sensors
b
Set up muting so that it is triggered by at least two signals (e.g., from muting
sensors) that are wired independently of one another and it is not fully dependent
on software signals (e.g., from a PLC).
b
Arrange the muting sensors so that if an intervention in the protective field occurs,
the hazardous area can only be reached once the dangerous state has been
eliminated. A condition for this is that the necessary minimum distances between
the ESPE and the hazardous area are maintained, typically in accordance with
EN ISO 13855.
b
Arrange the muting sensors so that material can pass unhindered but so no one
can enter the hazardous area by fulfilling the muting conditions themselves (i.e.,
by activating both muting sensors and thereby meeting the muting requirements).
Figure 7: Safety requirements when mounting the muting sensors
1
It must not be possible to activate sensors that are located opposite one another at
t
he same time.
PROJECT PLANNING 4
8024589/2020-11-10 | SICK O P E R A T I N G I N S T R U C T I O N S | Flexi Compact
19
Subject to change without notice
2
It must not be possible to activate sensors that are located next to one another at
t
he same time.
b
Ar
range the muting sensors so that only the moving material is detected, and not
the transportation equipment (pallet or vehicle).
Figure 8: Detection of material during muting
1
Transported material
2
Transportation equipment
3
Transport level
4
Muting sensor
b
S
et up the muting so that the material to be transported is detected over the entire
stretch. The output signals must not be interrupted.
b
Arrange the muting sensors so that a minimum distance is observed in relation to
the detection zone of the electro-sensitive protective equipment (e.g., in relation
to the light beams of a light curtain) whenever material is detected. The minimum
distance ensures the required processing time until muting is activated.
Safety notes for override
b
Mount t
he control switches for the Override functions outside of the hazardous
area so that they cannot be actuated by anyone who is located inside the haz‐
ardous area. In addition, the operator must have a complete overview of the
hazardous area when actuating a control switch.
b
Before activating the Override function, make sure that the equipment is in perfect
working order, particularly the muting sensors (visual inspection).
b
Make sure that the hazardous area is clear of people both before the Override
function is activated and while it is active.
b
If you have had to activate the Override function, check the functionality of the
equipment and the arrangement of the muting sensors after the event.
Safety notes for the muting/override lamp
b
Use a muting and/or override lamp to signal that the Muting or Override functions
are active. You can either use an external muting/override lamp or one that is
integrated into the electro-sensitive protective device (ESPE).
b
Always attach the muting and/or override lamps so that they are clearly visible.
The muting/override lamp must be visible from every side all the way around the
hazardous area and must be clearly visible to the system operator.
b
Depending on local, regional, and national regulations and standards, it may be
necessary to monitor the muting/override lamp(s). If this is the case, implement
additional measures for this purpose.
Further topics
"N
otes on wiring", page 26
4 PROJECT PLANNING
20
O P E R A T I N G I N S T R U C T I O N S | Flexi Compact 8024589/2020-11-10 | SICK
Subject to change without notice
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156

SICK Flexi Compact Safety controller Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI