4 Table of Contents WAGO-I/O-SYSTEM 750
750-464 2/4 AI RTD configurable
Manual
Version 1.1.0
4.3.2 Pt200 (acc. IEC 751) ......................................................................... 42
4.3.3 Pt500 (acc. IEC 751) ......................................................................... 43
4.3.4 Pt1000 (acc. IEC 751) ....................................................................... 44
4.3.5 Ni100 (acc. DIN 43760) ..................................................................... 45
4.3.6 Ni120 (Minco) .................................................................................... 46
4.3.7 Ni1000 (acc. DIN 43760) ................................................................... 47
4.3.8 Ni1000 TK5000 ................................................................................. 48
4.3.9 Resistance Measurement 10 Ohm … 1.2 kOhm ............................... 49
4.3.10 Resistance Measurement 10 Ohm … 5.0 kOhm ............................... 50
4.3.11 Potentiometer .................................................................................... 51
4.4.1 Process Data of the Standard Version 750-464
(RTD, configurable) Siemens Format ................................................ 52
4.4.2 Pt100 (acc. IEC 751) ......................................................................... 52
4.4.3 Pt200 (acc. IEC 751) ......................................................................... 53
4.4.4 Pt500 (acc. IEC 751) ......................................................................... 54
4.4.5 Pt1000 (acc. IEC 751) ....................................................................... 55
4.4.6 Ni100 (acc. DIN 43760) ..................................................................... 56
4.4.7 Ni120 (Minco) .................................................................................... 57
4.4.8 Ni1000 (acc. DIN 43760) ................................................................... 58
4.4.9 Ni1000 TK5000 ................................................................................. 59
4.4.10 Resistance Measurement 10 Ohm … 1.2 kOhm ............................... 60
4.4.11 Resistance Measurement 10 Ohm … 5.0 kOhm ............................... 61
4.4.12 Potentiometer .................................................................................... 62
4.5 Data of the Version 750-464/020-000 (NTC, configurable) ................... 63
4.5.1 NTC 10 kOhm ................................................................................... 63
4.5.2 NTC 20 kOhm ................................................................................... 64
4.5.3 NTC 10 kOhm Thermokon ................................................................ 65
4.6 Data of the Version 750-464/020-000 (NTC, configurable) Siemens
Format.................................................................................................... 66
4.6.1 NTC 10 kOhm ................................................................................... 66
4.6.2 NTC 20 kOhm ................................................................................... 67
4.6.3 NTC 10 kOhm Thermokon ................................................................ 68
5 Mounting ................................................................................................... 69
5.1 Mounting Sequence ............................................................................... 69
5.2 Inserting and Removing Devices ........................................................... 70
5.2.1 Inserting the I/O Module .................................................................... 70
5.2.2 Removing the I/O Module.................................................................. 71
6 Connect Devices ....................................................................................... 72
6.1 Connecting a Conductor to the CAGE CLAMP
®
.................................... 72
6.2 Connection Examples ............................................................................ 73
6.2.1 750-464 (RTD) Version, 4-Channel Operation .................................. 73
6.2.1.1 4 x 2-Wire ..................................................................................... 73
6.2.1.2 Special Features in 4-Channel Operation .................................... 73
6.2.1.2.1 Open Input Wiring .................................................................... 73
6.2.1.2.2 Measuring Circuit Line Break Detection ................................... 74
6.2.1.2.3 Influencing a Measuring Circuit Channel through a Quick
Change in Temperature ........................................................... 74
6.2.2 750-464 (RTD) Version, 2-Channel Operation .................................. 74
6.2.2.1 2 x 2-Wire ..................................................................................... 74