I Alarms
3. Servo/Spindle Alarms
I - 14
S01 Machine side dtc: Error 7 :PR 0029 (Axis name)
Details
An error was detected by the detector connected to the motor side.
The error details are different according to the connected detector. R
- AT343, AT543(Mitutoyo)
Static capacity type error
- LC191M,LC491M,RCN723,RCN223, APE391M(HEIDENHAIN)
Absolute position data error
- Futaba absolute position scale (Futaba)
Waveform error
- MP scale, MPI scale (Mitsubishi Heavy Industries)
Gain fault
- Resetting methods :PR
(Note) A driver processes all reset types of alarms as 'PR'. However, 'AR' will be applied
according to the detector.
- Stop method :Dynamic stop
S01 Machine side dtc: Error 8 :PR 002A (Axis name)
Details
An error was detected by the detector connected to the motor side.
The error details are different according to the connected detector.
- AT343, AT543(Mitutoyo)
Photoelectric type error
- LC191M,LC491M,RCN723,RCN223, APE391M(HEIDENHAIN)
Relative position data error
- Futaba absolute position scale (Futaba)
Overspeed Absolute position is lost
- MP scale, MPI scale (Mitsubishi Heavy Industries)
Phase fault
- MJ831(SONY)
Detector alarm
- Resetting methods :PR
(Note) A driver processes all reset types of alarms as 'PR'. However, 'AR' will be applied
according to the detector.
- Stop method :Dynamic stop
S01 Motor side dtc: Error 1 :PR 002B (Axis name)
Details
An error was detected by the detector connected to the motor side.
The error details are different according to the connected detector.
- OSA17,OSE104,OSE105,OSA104,OSA105,OSA405,OSA166(MITSUBISHI)
Memoryalarm
- OSA18(MITSUBISHI)
CPU alarm
- MDS-B-HR(MITSUBISHI)
Memory error
- AT343, AT543(Mitutoyo)
Initialization error
- LC191M,LC491M,RCN723,RCN223, APE391M(HEIDENHAIN)
Initialization error
- MP scale, MPI scale (Mitsubishi Heavy Industries)
Installation accuracy fault
- Resetting methods :PR
(Note) A driver processes all reset types of alarms as 'PR'. However, 'AR' will be applied
according to the detector.
- Stop method :Dynamic stop
S01 Motor side dtc: Error 2 :PR 002C (Axis name)
Details
An error was detected by the detector connected to the motor side.
The error details are different according to the connected detector.
- OSA17,OSE104,OSE105,OSA104,OSA105,OSA405,OSA166(MITSUBISHI)
LED alarm
- AT343, AT543(Mitutoyo)
EEPROM error
- LC191M,LC491M,RCN723,RCN223, APE391M(HEIDENHAIN)
EEPROM error
- Resetting methods :PR
(Note) A driver processes all reset types of alarms as 'PR'. However, 'AR' will be applied
according to the detector.
- Stop method :Dynamic stop
S01 Motor side dtc: Error 3 :PR 002D (Axis name)
Details
An error was detected by the detector connected to the motor side.
The error details are different according to the connected detector.
- OSA17,OSE104,OSE105,OSA104,OSA105,OSA405,OSA166(MITSUBISHI)
Data alarm
- OSA18(MITSUBISHI)
Data alarm
- MDS-B-HR(MITSUBISHI)
Data error
- AT343, AT543(Mitutoyo)
Photoelectric type, static capacity type data mismatch
- LC191M,LC491M,RCN723,RCN223, APE391M(HEIDENHAIN)
Relative/absolute position data mismatch
- MP scale, MPI scale(Mitsubishi Heavy Industries)
Detection position deviance
- Resetting methods :PR
(Note) A driver processes all reset types of alarms as 'PR'. However, 'AR' will be applied
according to the detector.
- Stop method :Dynamic stop