Sencore SDI2X User manual

Category
Supplementary music equipment
Type
User manual
April 2021
8089C www.sencore.com | 1.605.978.4600 Revision 1.2
SDI2X
SDI to IP Gateway
User Manual
SDI2X User Manual
Page 2 (61)
Copyright
© 2021 Sencore, Inc. All rights reserved.
3200 Sencore Drive, Sioux Falls, SD USA
www.sencore.com
This publication contains confidential, proprietary, and trade secret information. No part of this document may
be copied, photocopied, reproduced, translated, or reduced to any machine-readable or electronic format
without prior written permission from Sencore. Information in this document is subject to change without notice
and Sencore Inc. assumes no responsibility or liability for any errors or inaccuracies. Sencore, Sencore Inc,
and the Sencore logo are trademarks or registered trademarks in the United States and other countries. All
other products or services mentioned in this document are identified by the trademarks, service marks, or
product names as designated by the companies who market those products. Inquiries should be made directly
to those companies. This document may also have links to third-party web pages that are beyond the control
of Sencore. The presence of such links does not imply that Sencore endorses or recommends the content on
those pages. Sencore acknowledges the use of third-party open source software and licenses in some
Sencore products. This freely available source code can be obtained by contacting Sencore Inc.
About Sencore
Sencore is an engineering leader in the development of high-quality signal transmission solutions for the
broadcast, cable, satellite, IPTV, telecommunications, and professional audio/video markets. The
company’s world-class portfolio includes video delivery products, system monitoring and analysis solutions,
and test and measurement equipment, all designed to support system interoperability and backed by best-
in-class customer support. Sencore meets the rapidly changing needs of modern media by ensuring the
efficient delivery of high-quality video from the source to the home. For more information, visit
www.sencore.com.
SDI2X User Manual
Page 3 (61)
Revision History
Date (DD/MM/YYYY)
Version
Description
Author
09/25/2018
1.0
Initial Release
TDH
03/14/2019
1.1
Corrected typo and added Default IP values
TDH
04/23/2021
1.2
Update for 1.2.2 Feature Release
JDN
SDI2X User Manual
Page 4 (61)
Safety Instructions
Read these instructions
Keep these instructions
Heed all warnings
Follow all instructions
Do not use this apparatus near water
Clean only with dry cloth
Do not block any ventilation openings. Install in accordance with the
manufacturer’s instructions
Do not install near any heat sources such as radiators, heat registers, stoves, or
other apparatus (including amplifiers) that produce heat
Do not defeat the safety purpose of the polarized or grounding-type plug. A
polarized plug has two blades with one wider than the other. A grounding type
plug has two blades and a third grounding prong. The wide blade or the third
prong is provided for your safety. If the provided plug does not fit into your outlet,
consult an electrician for replacement of the obsolete outlet.
Protect the power cord from being walked on or pinched particularly at plugs,
convenience receptacles, and the point where they exit from the apparatus.
Only use attachments/accessories specified by the manufacturer.
Unplug this apparatus during lightning storms or when unused for long periods of
time.
Refer all servicing to qualified service personnel. Servicing is required when the
apparatus has been damaged in any way, such as power-supply cord or plug is
damaged, liquid has been spilled or objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture, does not operate normally, or
has been dropped.
Do not expose this apparatus to dripping or splashing and ensure that no objects
filled with liquids, such as vases, are placed on the apparatus.
To completely disconnect this apparatus from the AC Mains, disconnect the
power supply cord plug from the AC receptacle.
The mains plug of the power supply cord shall remain readily operable.
Damage Requiring Service: Unplug this product from the wall outlet and refer
servicing to qualified service personnel under the following conditions:
o When the power-supply cord or plug is damaged.
o If liquid has been spilled, or objects have fallen into the product.
o If the product has been exposed to rain or water.
o If the product does not operate normally by following the operating
instructions. Adjust only those controls that are covered by the
operating instructions as an improper adjustment of the controls may
result in damage and will often require extensive work by a qualified
technician to restore the product to its normal operation.
o If the product has been dropped or damaged in any way.
o The product exhibits a distinct change in performance.
Replacement Parts: When replacement parts are required, be sure the service
technician uses replacement parts specified by Sencore, or parts having the
same operating characteristics as the original parts. Unauthorized part
substitutions made may result in fire, electric shock or other hazards.
SDI2X User Manual
Page 5 (61)
SAFETY PRECAUTIONS
There is always a danger present when using electronic equipment.
Unexpected high voltages can be present at unusual locations in defective
equipment and signal distribution systems. Become familiar with the equipment
that you are working with and observe the following safety precautions.
Every precaution has been taken in the design of your SDI2X to ensure that it is
as safe as possible. However, safe operation depends on you the operator.
Always be sure your equipment is in good working order. Ensure that all points
of connection are secure to the chassis and that protective covers are in place
and secured with fasteners.
Never work alone when working in hazardous conditions. Always have another
person close by in case of an accident.
Always refer to the manual for safe operation. If you have a question about the
application or operation call Sencore for assistance.
WARNING To reduce the risk of fire or electrical shock never allow your
equipment to be exposed to water, rain or high moisture environments. If exposed
to a liquid, remove power safely (at the breaker) and send your equipment to be
serviced by a qualified technician.
To reduce the risk of shock the SDI2X must be connected to a mains socket outlet
with a protective earthing connection.
For the SDI2X the mains plug is the main disconnect and should remain readily
accessible and operable at all times.
The SDI2X is equipped with an internal system battery. The SDI2X must be sent
to Sencore service for replacement of this battery.
When installing the SDI2X utilizing the DC power supply, the power supply MUST
be used in conjunction with an over-current protective device rated at 50 V, 5 A,
type: Slow-blo, as part of battery-supply circuit.
To reduce the risk of shock and damage to equipment, it is recommended that the
chassis grounding screw located on the rear of the SDI2X be connected to the
installation’s rack, the vehicle’s chassis, the battery’s negative terminal, and/or
earth ground.
CAUTION Danger of explosion if battery is incorrectly replaced. Replace only
with the same or equivalent type.
SDI2X User Manual
Page 6 (61)
FCC Class A Information
The SDI2X has been tested and found to comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is
likely to cause harmful interference in which case the user will be required to correct the
interference at his or her own expense.
Shielded cables must be used with this unit to ensure compliance with the Class A FCC
limits.
Warning: Changes or modifications to this unit not expressly approved by the
party responsible for compliance could void the user’s authority to operate the
equipment.
Dolby Digital Information
This product has been manufactured under license from Dolby Laboratories.
Dolby Digital, AC-3”, and Dolby Digital Plus are licensed trademarks of Dolby
Laboratories.
SDI2X User Manual
Page 7 (61)
Package Contents
The following is a list of the items that are included along with the SDI2X:
1. AC Power Cable
2. Quick Start Guide
Note: If any option cables were ordered with the SDI2X, they will be included in the box
as well.
If any of these items were omitted from the packaging of the SDI2X please call 1-800-
SENCORE to obtain a replacement. Manuals for Sencore products can be downloaded at
www.sencore.com
1) AC Power Cable
2) Quick Start Guide
SDI2X User Manual
Page 8 (61)
Table of Contents
Section 1 Overview ........................................................................................... 10
1.1 Product Introduction ................................................................................................... 11
1.2 Front Panel Overview ................................................................................................ 11
1.3 Rear Panel Overview ................................................................................................. 12
1.4 Cooling ....................................................................................................................... 12
1.5 Rack Information ........................................................................................................ 13
Section 2 Installation ........................................................................................ 14
2.1 Installation .................................................................................................................. 15
2.2 AC Power Connection ............................................................................................... 15
2.3 Maintenance .............................................................................................................. 15
2.4 Management Network Setup via Front Panel ............................................................ 15
Section 3 Operating the Front Panel ............................................................... 18
3.1 SDI2X Front Panel Overview ..................................................................................... 19
Section 4 Operating the Web Interface ........................................................... 20
4.1 SDI2X Web Interface Overview ................................................................................. 21
4.1.1 Logging into the SDI2X Web Interface ................................................................. 21
4.1.2 Control Panels ...................................................................................................... 21
4.1.3 Title ribbons .......................................................................................................... 22
4.1.4 Buttons and Status Indicators............................................................................... 22
Section 5 Web Interface Control Panels ......................................................... 23
5.1 SMPTE Control Panel ................................................................................................ 24
5.1.1 HDMI Monitoring Output ....................................................................................... 24
5.1.2 Channel Configuration .......................................................................................... 25
5.1.3 Configuring the Video/IP ports (SDI IP) ........................................................... 26
5.1.4 Configuring the Video/IP ports (IP SDI) ........................................................... 29
5.2 Admin Control Panel .................................................................................................. 34
5.2.1 Changing Unit Password ...................................................................................... 34
5.2.2 Profiles .................................................................................................................. 34
5.2.3 SNMP MIB files .................................................................................................... 36
5.2.4 Diagnostics ........................................................................................................... 36
5.2.5 Updating the SDI2X software ............................................................................... 37
5.2.6 Reboot the unit .................................................................................................... 39
5.2.7 Reset to Defaults ................................................................................................. 39
5.2.8 UID Indicator ......................................................................................................... 40
5.2.9 Unit Alias............................................................................................................... 40
5.2.10 Configuring the Network Ports ............................................................................. 41
5.2.11 Configuring SNMP ................................................................................................ 46
5.2.12 Syslog ................................................................................................................... 47
5.3 Reporting Panel ......................................................................................................... 47
5.3.1 Alarms ................................................................................................................... 48
5.3.2 Configuring the Alarms ......................................................................................... 49
5.3.3 Event Logs ............................................................................................................ 51
5.3.4 Configuring the Logs ............................................................................................ 52
5.4 About Control Panel ................................................................................................... 52
5.4.1 System Information ............................................................................................... 52
5.4.2 Contact Information .............................................................................................. 53
5.4.3 Hardware .............................................................................................................. 53
5.4.4 Third Party Software Information .......................................................................... 53
5.4.5 System Recovery ................................................................................................. 53
SDI2X User Manual
Page 9 (61)
Section 6 Appendices ....................................................................................... 54
Appendix A Error and Event List ........................................................... 55
Appendix B Acronyms and Glossary .................................................... 56
Appendix C Specifications ..................................................................... 57
Appendix D Warranty ............................................................................. 58
Appendix E Support and Contact Information ..................................... 58
Appendix F Open Source Software ....................................................... 59
SDI2X User Manual
Page 10 (61)
Section 1 Overview
Introduction
This section includes the following topics:
1.1 Product Introduction ................................................................................................... 11
1.2 Front Panel Overview ................................................................................................ 11
1.3 Rear Panel Overview ................................................................................................. 12
1.4 Cooling ....................................................................................................................... 12
1.5 Rack Information ........................................................................................................ 13
SDI2X User Manual
Page 11 (61)
1.1 Product Introduction
The new SDI2X is a simple solution to bridge the gap between traditional SDI and IP
infrastructure. The SDI2X maintains the long standing Sencore tradition of coupling ease
of use, with a straight-forward web interface to give the user complete control of the unit
and signals being processed.
The SDI2X supports both SDI to IP and IP to SDI workflows, and with its powerful
processor, chosen with future standards in mind, the SDI2X will be a convenient tool for
years to come.
Designed flexibly to support SMPTE 2022-6 and TR-03/SMPTE 2110. The SDI2X is a
must have for those considering baseband A/V over IP deployments.
The SDI2X platform supports one or more channels which can be configured to convert
SDI video inputs into IP output streams, or IP input streams into SDI video outputs. The
user can configure the direction (SDI->IP or IP->SDI) for each channel independently.
The platform will encapsulate or de-encapsulate the SDI video according to SMPTE
2022-6 standard.
The platform also supports redundancy using SMPTE 2022-7 seamless switching
standard.
1.2 Front Panel Overview
The SDI2X front panel will provide the user with:
1. Error Indicator
2. LCD Screen
3. Up, Down, Left, Right Buttons
4. Back and Ok Buttons
5. Unit Identification LED
1
SDI2X User Manual
Page 12 (61)
1.3 Rear Panel Overview
The SDI2X comes standard with all of the hardware listed below except where noted as
a factory installed option. back panel will provide the user with the following
connections:
1. RJ45 Management Port
2. Unit Identification LED
3. Four 3G/HD/SD-SDI Bi-directional ports
4. HDMI Output
5. Data Path 1: One of two SFP ports for SMPTE 2022-6/2110 uncompressed video
over IP
6. Data Path 2: One of two SFP ports for SMPTE 2-22-6/2110 uncompressed video
over IP
Sencore offers three (3) optional SFP adaptors that will allow the user the following
port configurations
10G Fiber (Sencore part SDI2X-10G-SFP-FIBER)
1G Fiber (Sencore part SDI2X-1G-SFP-FIBER)
1G RJ45 Copper (Sencore part SDI2X-RJ45-COPPER)
1.4 Cooling
The SSDI2X is cooled via forced induction through the front of the unit and exhausted
through the vents in the rear. The unit is equipped with a internal temperature sensor.
If the internal temperature exceeds 60°C the “Error” LED will illuminate on the front
panel and an error message will appear in the “Error List.”
2
1
3
5
6
SDI2X User Manual
Page 13 (61)
1.5 Rack Information
The SDI2X is versatile and was designed to be deployed as a ‘throw down’ device for
easy installation into locations with limited space. With the optional rack mount kit, the
user can deploy three (3) SDI2X in a standard 19” rack and occupy slightly more than
1RU of rack space.
SDI2X User Manual
Page 14 (61)
Section 2 Installation
Introduction
This section includes the following topics:
2.1 Installation .................................................................................................................. 15
2.2 AC Power Connection ............................................................................................... 15
2.3 Maintenance .............................................................................................................. 15
2.4 Management Network Setup via Front Panel ............................................................ 15
SDI2X User Manual
Page 15 (61)
2.1 Installation
The SDI2X is small enough to be deployed as a standalone device, or placed into a rack
system using the optional rack mount (Sencore part number 7C1489) hardware which
will allow up to three (3) SDI2X to occupy a space slightly more than 1 rack unit.
2.2 AC Power Connection
The SDI2X is powered by a single connection to a 120V 60Hz source.To hook up the
power use the following steps:
1. Locate the AC power cord that was included.
2. Plug the female end (end with no prongs) of power cord into the back of the unit.
3. Locate a protected outlet to plug the male end of the power cable into.
2.3 Maintenance
The SDI2X is virtually a maintenance-free piece of equipment. There are no user
serviceable parts on the inside of the unit
2.4 Management Network Setup via Front Panel
By default the management IP address will be static, and use the following settings
Address = 10.0.0.61; Subnet Mask = 255.255.255.0; Default Gateway = 0.0.0.0
The SDI2X can be setup on a network connection to allow remote management and
SNMP configuration. For these features to work, the network settings for the SDI2X must
first be configured properly for the network it is connected to.
Static IP Address
To setup the SDI2X with a static IP address, use the following steps:
1. Press the button.
2. Use the and buttons to
move the cursor to “Admin”, then
press the button.
SDI2X User Manual
Page 16 (61)
3. Use the and buttons to
move the cursor to “Unit Network”,
then press the button.
4. Use the and buttons to
move the cursor to “Mode”, then
press the button.
Use the and buttons to
change the selection to “Static” then
press the button.
IP Address/Subnet Mask/Gateway
1. Use the and buttons to
move the cursor to “IP Address”,
then press the button.
2. Use the and buttons to
select the column to edit and use the
and buttons to change
the location value. Press the
button to save the selection and the
button to return to setting
selection.
3. Repeat steps 1 and 2 for “Subnet
Mask” and “Gateway” configuration
settings.
DHCP
The SDI2X can be configured to use DHCP to obtain an IP address/Subnet
Mask/Gateway.
SDI2X User Manual
Page 17 (61)
1. Use the and buttons to
move the cursor to “Mode:” then
press the button.
2. Use the and buttons to
change the selection to “DHCP”
then press the button to save
the selection.
Note: It may take up to a minute for the SDI2X to obtain an IP address. During this
time the unit will display a “busy” message next to DHCP.
SDI2X User Manual
Page 18 (61)
Section 3 Operating the Front
Panel
Introduction
This section includes the following topics:
3.1 SDI2X Front Panel Overview ..................................................................................... 19
SDI2X User Manual
Page 19 (61)
3.1 SDI2X Front Panel Overview
The SDI2X front panel allows the user to configure all settings that are present in the
web interface using the buttons located on the front of the unit. The screen below is the
idle screen of the SDI2X and provides the user with the following details at a glance
1. IP address of management port
2. Current path configuration of each available channel.
3. Stream processing condition of each path.
When viewing the menu screens, it is important to observe some of the important
features that have been noted below. They are common to all screens and provide
helpful information. The button allows the user to return to the home screen,
cancel settings and go back a menu. The button is used to select and save
selections.
1. Screen title.
2. Icons indicate which control buttons are currently valid for entry.
3. Cursor shows which line is active.
4. When editing, active character or item is highlighted.
1
4
2
3
1
3
SDI2X User Manual
Page 20 (61)
Section 4 Operating the Web
Interface
Introduction
This section includes the following topics:
4.1 SDI2X Web Interface Overview ................................................................................. 21
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61

Sencore SDI2X User manual

Category
Supplementary music equipment
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI