Allterco Robotics MyKi Care User manual

Category
Environment thermometers
Type
User manual
MyKiCareThermometer(MCT1.0) USERMANUAL
AlltercoRoboticsLTD.1404Sofia,Bulgariaphone+35929571247www.MyKi.Caresupport@myki.care
Precautionsforuse
Anyformofmodificationtothisdeviceis
forbidden;
Don’tusethedevicetogetherwithMRIor
CTequipment;
Explosiondanger:don’tusethedevicein
flammableanestheticgas;
Don’tsqueezethedevice.Ifthehousingis
broken,pleasestopusingthedevice.
Please
checkdeviceregularlytomake
surethatit makescontactwithskintightly;
otherwisethedatamaybeinaccurate.
Thedeviceisforindooruseonly;
Pleasepayattentiontotheoperation
temperatureandhumidity.Usingthe
thermometerinaconditionthatdoesnot
satisfytherequirementmayleadto
measurementerror;
Theeffectivewirelesstransmission
distanceis10minabarrierfree
environment.Thethermometermaynot
workifattemptingtouseatgreater
distances.Pleaseusethisproductwithin
effectivewirelesstransmissiondistance;
Muscleandfataffectwireless
transmission,sothetransmissionrange
maybeweakenedwhen
obeseadultor
childusesthedevice.
Magneticandelectricalfieldsarecapable
ofinterferingwiththeproperperformance
ofthethermometer.Forthisreasonmake
surethatallexternalequipmentoperated
inthevicinityofthethermometer
complieswiththerelevantEMC
requirement.Mobilephone,Xray
equipmentor
MRIdevicesareapossible
sourceofinterferenceastheymayemit
higherlevelsofelectromagneticradiation.
Thethermometerisnotsterile;
Doctorshoulddiagnoseclinicalsymptoms,
onlywithusingthethermometeras
subsidiary;
Thisproducthasbeencalibrated.No
otherroutinemaintenanceandcalibration
isneededinaddition
tothereplacement
battery;
Ifthesystemupgrade,pleaseupdatethe
program;
Itisveryunlikelythatthethermometeris
notcompatiblewiththemobileappon
yourmobiledevice.Pleasecontactusif
youexperiencethisproblem;
Ifyouhavequestionsconcerningsetting
up,using,maintenanceofthe
thermometeroranyunexpectedevents,
pleasecontactMyKiCaresupportat:
Whenthepatientistheoperator,please
useandmaintainthethermometer
accordingtothismanual.
Werecommendtheuserstousethe
originalmanufacturedadhesivepads.To
getbestreadingonthermometer use ina
coolenvironment.
Ifyoufeelunwell
(uncomfortableorallergic)whenusingthe
adhesivepad,pleasediscardandstop
usingadhesivepadandfollowdoctor’s
advice.
Whenmeasuringforalongtime,please
checkwhetherthereanallergicreaction
withskin.Ifthereisanallergicreaction,
youshouldstopusingthethermometer
immediately.
Pleasedonotrepastetheadhesivepadif
itappearsused,Anewadhesivepadis
required.
Skinpreparationinadvanceisrequired
whenwornbyadult.Pleasemakesure
thatskiniscleananddry.
Pleasecleanthesurfaceofthe
thermometerwith75%concentrated
medical
alcoholbeforeandafterusingit.
Youshouldcleantheskincontactedthe
MyKiCareThermometer(MCT1.0) USERMANUAL
AlltercoRoboticsLTD.1404Sofia,Bulgariaphone+35929571247www.MyKi.Caresupport@myki.care
thermometerwithmedicinalalcoholafter
takingoffthedevice.Thematerialthat
contactsskinisnontoxic,nonirritatingand
willnotcauseallergyoranyotherside
effect.
Onemayexperienceanallergicreaction
orpossibleothersideeffectIfpetsor
peststouchthedevice.Pleasecleanthe
surface
ofthedevicewith75%
concentratedmedicalalcoholbeforeusing
it.
Ifchildrentamperorplaywiththedevice,
thismaydamagethetemperature
measuringprobeandaffectthemeasure
accuracy.
Thethermometerstartsupwhenyou
shakeitintensiveduring3seconds.When
isstrarttheredlightis
blinking5times.If
youshakeitduringtheworktheredlight
isblinkfor3times.Thermometershuts
downautomaticallywhenthe
temperatureisunder35degreeandnot
shackedfor5min.
Thethermometersendstemperatureto
thedeviceevery812seconds.
Thisproducthasoverrun
prompted
function,anduserscansetthealarmlimit
themselves.ThisdevicecomplieswithPart
15oftheFCCRules.Operationissubject
tothefollowingtwoconditions:(1)This
devicemaynotcauseharmfulinterference;
(2)Thisdevicemustacceptany
interferencereceived,including
interferencethatmaycauseundesired
operation.
Theuseriscautionedthat
changesormodificationsnotexpressly
approvedbythepartyresponsiblefor
compliancecouldvoidtheuser'sauthority
tooperatetheequipmentFCC
STATEMENT:
Thisequipmenthasbeentestedand
foundtocomplywiththelimitsforaClass
Bdigitaldevice,pursuanttoPart15
ofthe
FCCRules.Theselimitsaredesignedto
providereasonableprotectionagainst
harmfulinterferenceinaresidential
installation.Thisequipmentgenerates,
usesandcanradiateradiofrequency
energyand,ifnotinstalledandusedin
accordancewiththeinstructions ,may
causeharmfulinterferencetoradio
communications.However,thereis
no
guaranteethatinterferencewillnotoccur
inaparticularinstallation.
Ifthisequipmentdoescauseharmful
interferencetoradioortelevision
reception,whichcanbedeterminedby
turningtheequipmentoffandon,theuser
isencouragedtotrytocorrectthe
interferencebyoneormoreofthe
followingmeasures:‐‐Reorientorrelocate
thereceivingantenna.‐‐Increasethe
separationbetweentheequipmentand
receiver.‐‐Connecttheequipmentintoan
outletonacircuitdifferentfromthatto
whichthereceiverisconnected.‐‐Consult
thedealeroranexperiencedradio/TV
technicianforhe lp.
IntendedUse
Thedeviceisintended
tobeusedfor
measuringandmonitoringhuman
temperaturecontinuously.Itcanstoreand
managethetemperaturedata.Itcanbe
usedtomeasurearmpittemperaturefor
theadult,pediatricandneonatepeople.
Thedeviceisnotwaterproofandcannot
usedtomeasureliquidtemperature.
DownloadAndInstallTheSoftware
The
ThermometeriscompatiblewithiOS
7+andAndroid5+devices.Touseitopen
theAppstoreforiOSorGooglePlayfor
Androidanddownloadtheapplication
MyKiCare.
OperationInstructions
1. OpenMyKiCareapplicationand
createaccount.
MyKiCareThermometer(MCT1.0) USERMANUAL
AlltercoRoboticsLTD.1404Sofia,Bulgariaphone+35929571247www.MyKi.Caresupport@myki.care
2. Logininyouraccountandinput
patientdata.
3. ShaketheThermometerfor3
seconds,duringtheredlightstart
blinkingfor5seconds.
4. PressontheIDofthe
Thermometer
5. PlacetheThermometerunderthe
armwithmetalparttothebody.
6. Put
theadhesivepadcarefully.If
youneedtoreplacechangethe
adhesivepad.
Changeadhesivepadevery2hours
duringthedayand68hoursduringthe
night.
MyKiCareThermometer(MCT1.0) USERMANUAL
AlltercoRoboticsLTD.1404Sofia,Bulgariaphone+35929571247www.MyKi.Caresupport@myki.care
Thermometerneed1215minto
measureandshowthebody
temperature.
Youcanusethermometerformultiple
patientsinoneapplication.Toaddnew
patientjustslidelefttorightandfollow
thescreeninstruction.
Youcanwatchthethermometerdata
fromunlimiteddevicesatsametime.For
that,
alldevicesshouldsharesame
account.
Onlyoneofalldevicesshouldbeupto10
meterstothethermometer.Alldata
automaticallyuploadtothecloudandall
otherdevicescanseewhenevertheyare.
Youshouldtohaveinternetconnectionto
alldevices.
Setcorrectalarmsettingbase
ofyour
requirements.
Thealarmmaybenotworkifyouyour
mobilephonedonothaveinternet,
notificationsisforbidden,yourdeviceisin
DNDmodeornotificationservicesis
temporaryinaccessible.
MyKiCareThermometer(MCT1.0) USERMANUAL
AlltercoRoboticsLTD.1404Sofia,Bulgariaphone+35929571247www.MyKi.Caresupport@myki.care
Productspecifications:

Productname: MyKiCareThermometer
Productmodel: MCT1.0
Weightwithout
battery:
Measure
specifications
Measurescope
34.00Ԩ45.00Ԩ(93.00Ԭ113.00Ԭ)
Measureaccuracy+/‐0.1C(0.18F)
Temperatureunit CorF
Updatetime Every812seconds
Light Bliningwhenshaked
Softwareplatform
iOS 7+version
Android 5+version
Battery
Type CR2025,3V/163mAHbuttonbattery
Worktime 7days/8hperday
Environment
specifications
Temperature Operating:5
+45;
Transportationandstorage:‐20Ԩ+55Ԩ.
Humidity
Operating:25%95%noncondensing)
Transportationandstorage:25%95%
(noncondensing)
Atmospheric
pressure
Operating:700hPa1060hPa;
Transportationandstorage:
500hPa1060hPa.
Possibleproblemsandsolutions:
Symptom Solution
Devicenotwakeup
whenIshakeit.Red
lightdonotappear.
Checkthebattery.Carefullyopenthedevice
andreplacethebatterywithnewone.
Temperatureisnot
correctafter20min
Checkthedeviceposition.Mustbeunderarm
withmetalcapconnectedtothebody.Replace
theadhestivepad.
Thermometerdonot
connecttothemobile
device
Forchildrenmobilephoneshouldmeunder
10meterfromthethermometer.For
adults,mobilephoneshouldbeunder2meters
tothethermometer.
CheckareyourBluetoothisactivated.
Cannotremembermu
accountdetails.
Createnewaccountandaddthemormtertoit
orcontactwith:[email protected]
Guidanceandmanufacture’sdeclarationofEMC
Thedeviceisintendedforuseintheelectromagneticenvironment
specifiedbelow.Thecustomeroftheuserofthedeviceshould
assurethatitisusedinsuchanenvironment.
Emissiontest Compliance
RFemissionsCISPR11 Group1
RFemissionCISPR11 ClassB
HarmonicemissionsIEC6100032
Notapplicable(Battery
operateddevice)
Voltagefluctuations/flicker
emissionsIEC6100033
Notapplicable(Battery
operateddevice)
SAR …………….
MyKiCareThermometer(MCT1.0) USERMANUAL
AlltercoRoboticsLTD.1404Sofia,Bulgariaphone+35929571247www.MyKi.Caresupport@myki.care
Operation Frequency:
Bluetooth: 2402-2480MHz, 40 channels for BLE
Max. RF output power: Bluetooth: -0.70dBm
Hardware Version: MT01CY
Software Version: FW-MT01
Environmental Conditions:
Working Temperature: 5 ~ 45 Working humidity: 25~95%RH
Bluetooth can be used in Europe without restriction.
Hereby, Allterco Robotics, declares that this MyKi Care - Thermometer /
MCT 1.0 is In compliance with the essential Requirements and other
relevant provisions of RE Directive 2014/53/EU.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Allterco Robotics MyKi Care User manual

Category
Environment thermometers
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI