Titan Series High Power Microinverter is a small device designed to convert DC power generated by photovoltaic panels into AC power. It features easy installation and monitoring via a dedicated mobile app. The microinverter is suitable for installation on structures underneath solar panels where it works in the shade without touching the rooftop. It offers protection against adverse environmental conditions and ensures efficient operation. The Titan Series microinverter provides reliable solar power conversion for residential and commercial applications.

Titan Series High Power Microinverter is a small device designed to convert DC power generated by photovoltaic panels into AC power. It features easy installation and monitoring via a dedicated mobile app. The microinverter is suitable for installation on structures underneath solar panels where it works in the shade without touching the rooftop. It offers protection against adverse environmental conditions and ensures efficient operation. The Titan Series microinverter provides reliable solar power conversion for residential and commercial applications.

Check the Installation Environment and Position
Installation Steps
Step 3. Connect the AC cable
DANGER
DANGER
WARNING
CAUTION
TITAN MICROINVERTER
QUICK INSTALLATION GUIDE
When choosing the position of installation, comply with the following
conditions:
Choose the best installation position. Use two pairs of screws and
nuts to x the microinveer on the frame. Make sure that the label
of microinveer should be upside.
Take out the AC connector from the package. Get the AC cable
through the shell of AC connecter and connect the cable to the
· To avoid unwanted power derating due to an increase in the
sunlight.
may be present.
correct operation of electronic equipment.
· It's recommended to install microinveer on structures
underneath the photovoltaic modules so that they work in the
shade without touching the rooftop.
· Use a mobile phone to check the Wi-Fi signal strength at the
microinveer installation position. If the Wi-Fi signal is weak,
t to install the micro inveer in another place with better signal,
or move the Wi-Fi router or repeater closer
clearances.
incorrect installation and operation may lead to serious safety and
shock hazards or equipment damage.
·Be aware that installation of this equipment includes risk of electric
shock.
Do not install the equipment in adverse environment conditions such
and humid.
with good ventilation and no directly sunshine.
There are no screws and nuts in the package.
DANGER
WARNING
CAUTION
from the system.
disconnected from the home distribution network and the AC breaker
is open.
·Ensure that all AC cables are correctly wired and that none of the
wires are pinched or damaged.
·Use AWG 12 ( 4 mm²) cable for AC end cable.
·The installation technician is responsible for selecting a kind of AC
distribution network correctly.
L: Live (Brown/Red)
N: Neutral (Blue/Black)
PE: Ground (Yellow-Green)
Step 2. Connect the ground cable
WARNING
·Ensure that all
·Use φ6 screw for .
The micro inveer can also be mounted on the wall (veically)
using the optional suppo. In this case, rst x the bracket to the
wall with a pair of screws and then x the micro inveer to the
bracket with one pair of nut screws.
11061400301 V1.2
Step 4. Connect the DC cable
Step 5. Make an installation map
modules in series.
the information of the solar plant.
a two-minute wait time.
CAUTION
installation site.
direction on the upper left corner means the actual installation
orientation.
DANGER
WARNING
CAUTION
DANGER
CAUTION
Status
Solid Green Standby/Waiting/Checking Status
Working normally
Working abnormally
Fault
Flashing Green (1s)
Flashing Red (1s)
Solid Red
Indicates
TSUNESS Co,. Ltd
WEB : www.tsun-ess.com
7 Download the monitoring App
Talent Home
Talent Home
Follow the user guidance and complete all the operations in
the App.
11061400301 V1.2
6
· When photovoltaic panels are exposed to light, it provides a DC
voltage to the inveer.
· Make sure that all DC cables are correctly connected and that none
of the cables are stripped, pinched or damaged.
· The maximum open circuit voltage of the photovoltaic module (panel)
must not exceed the specication of the maximum input DC voltage of
the micro inveer.
· If the DC cable is sho for installation, use a DC extension cable to
connect PV modules to the micro inveer.
· Use MC4 compatible DC connectors for the DC extension cable on the
micro inveer side or get DC connectors from TSUNESS.
· Only qualied personnel may connect this system to the utility grid.
· Do not connect the microinveer(s) to the grid, nor energize the AC
circuit(s) until you have completed all installation procedures and have
received prior approval from the electricity utility company.
The LED will ash green and red on staup. The LED denition is
shown below:
  • Page 1 1
  • Page 2 2

Titan Series High Power Microinverter User guide

Type
User guide

Titan Series High Power Microinverter is a small device designed to convert DC power generated by photovoltaic panels into AC power. It features easy installation and monitoring via a dedicated mobile app. The microinverter is suitable for installation on structures underneath solar panels where it works in the shade without touching the rooftop. It offers protection against adverse environmental conditions and ensures efficient operation. The Titan Series microinverter provides reliable solar power conversion for residential and commercial applications.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI