Braeburn Systems Braeburn 3020 3220 Wall Thermostat User manual

Category
Heat pumps
Type
User manual

This manual is also suitable for

Detailed
Installer Guide
Non-Programmable Thermostats
1
Specifications
2
Installation and Wiring
3
Quick Reference
4
Installer Settings
5
System Testing
• Possible electric shock or damage to equipment can occur.
• Disconnect power before beginning installation.
Caution
This thermostat requires 24 Volt AC Power or 2 properly installed “AAAlkaline
batteries for
proper operation. When connecting 24 Volt AC Power the batteries may
be installed as a backup.
For use only as described in this manual. Any other use will void warranty.
3020
Single Stage Heat / Cool Conventional
or Heat Pump
3220
Up to 3 Heat / 2 Cool Heat Pump
Up to 2 Heat / 2 Cool Conventional
Warning
For installation by experienced service technicians only.
®
This thermostat is compatible with:
• Singlestageheat/coolconventionalandheatpumpsystems
• Conventionalsystemsupto2stagesofheatingand2stagesofcooling(3220only)
• Heatpumpsystemsupto3stagesofheatingand2stagesofcooling(3220only)
• 250–750millivoltheatingonlysystems
• 2or3wirehydroniczonesystems
Electrical and control specifications:
• ElectricalRating:24VoltAC
• 1ampmaximumloadperterminal
• ACPower:18–30VoltsAC
• DCPower:3.0VoltDC(2“AAAlkalineBatteriesIncluded)
• ControlRange:45°–90°F(7°–32°C)
• TemperatureAccuracy:+/-1°F(+/-.5°C)
• OutdoorTemperatureDisplayRange:-40°-120°F(-40°-49°C)
Terminations
• 3020:G,Rc,Rh,W1,O/B/V3,Y1,C,S1,S2
• 3220:G,Rc,Rh,W1/E/W3,W2,O/B/V3,Y1,Y2,C,L,S1,S2
1
Specifications
3020W-100-02
Model number is located on back of thermostat.
PREMIER
SERIES
Thermostat Location
Installthethermostatapproximately5feet(1.5m)abovetheoorinanareathathasagoodamountofair
circulationandmaintainsanaverageroomtemperature.
Avoidinstallationinlocationswherethethermostatcanbeaffectedbydrafts,deadairspots,hotorcoldair
ducts,sunlight,appliances,concealedpipes,chimneysandoutsidewalls.
Installer Guide 2
Install your new Braeburn thermostat in 4 basic steps:
1 InstalltheSub-Base
2 ProvidePower
3 ConnectYourWires
4 AttachThermostattoSub-Base
Install the Sub-Base:
•Removethesub-basefromthebodyofthethermostat.
•Mountthesub-baseasshownbelow:
Warning
Disconnect power before beginning installation.
2
Installation and Wiring
1
UP
UP
Drill 3/16” pilot holes in your
desired location. Use supplied
anchors for drywall or plaster.
3 Installer Guide
Provide Power
C
24VAC Power Terminal (C)
2
Wiring Terminations for model 3020
Terminal Function Description
 Rc Input 24VoltACCoolingTransformer
(DualTransformerSystemsOnly)
 Rh Input PowerConnection(24VoltACHeating
TransformerorMillivoltPowerSource)
G Output FanControl
W1 Output ConventionalHeatRelay
O/B/V3 Output (O)CoolActiveReversingValve
(B)HeatActiveReversingValve
(V3)ZoneValvePowerClose
Y1 Output CompressorRelay
C Input 24VoltACTransformerCommon
S1
S2
Connect Your Wires
3
Input OptionalRemoteSensor(indoororoutdoor)
+
+
For24VoltACpower,youmustconnectthecommonsideofthetransformertotheCterminalonthethermostatsub-base.In
dualtransformerinstallations,thetransformercommonmustcomefromthecoolingtransformer.
• Forbatterypower,insertthe2supplied“AA”typealkalinebatteriesintothebatterycompartmentlocatedintherear
housingofthethermostat.MakesuretopositionthePositive(+)andNegative(-)sidesofthebatteriescorrectlywith
the+/-symbolsinthebatterycompartment.
Batteries Installed as Shown
Installer Guide 4
Wiring Terminations for model 3220
Terminal Function Description
  Rc Input 24VoltACCoolingTransformer
(DualTransformerSystemsOnly)
Rh Input PowerConnection(24VoltACHeating
TransformerorMillivoltPowerSource)
G Output FanControl
W1/E/W3 Output (W1)1stStageConventionalHeat,
  (E)EmergencyHeat,
(W3)3rdStageAuxiliaryHeat
W2 Output 2ndStageConventionalHeat
O/B/V3 Output (O)CoolActiveReversingValve
(B)HeatActiveReversingValve
(V3)ZoneValvePowerClose
  Y1 Output 1stStageCompressor
  Y2 Output 2ndStageCompressor
  L Input SystemMalfunctionIndicator
C Input 24VoltACTransformerCommon
  S1
  S2
Connecting Your Wires (continued)
3
Input OptionalRemoteSensor(indoororoutdoor)
5 Installer Guide
Heat Only or Millivolt
Set System Type to 11CONV
Rh PowerConnection
W1 HeatRelay
G FanRelay[note 4]
C 24VoltACTransformerCommon[note 1]
1 HEAT / 1 COOL Single or Dual Transformer
Set System Type to 11CONV
Rh
24VoltACPower(heatingtransformer)[note 2]
Rc
24VoltACPower(coolingtransformer)[note 2]
W1 HeatRelay
Y1 CompressorRelay
G FanRelay
C 24VoltACTransformerCommon[note 1, 3]
NOTES - Conventional Systems
[1]Optional24VoltACcommonconnection.
[2]Removefactoryinstalledjumperfordual
transformersystems.
[3]Indualtransformersystems,transformer
commonmustcomefromcoolingtransformer.
[4]Ifneededforsystem.
Provide disconnect and overload protection as required.
2 HEAT / 2 COOL Single or Dual transformer
Set System Type to 22CONV
Rh
24VoltACPower(heatingtransformer)[note 2]
Rc
24VoltACPower(coolingtransformer)[note 2]
W1 HeatRelayStage1
W2 HeatRelayStage2
Y1 CompressorRelayStage1
Y2 CompressorRelayStage2 [note 4]
G FanRelay
C 24VoltACTransformerCommon[note 1, 3]
Typical Wiring Congurations
NOTE: The “System Type” option will be configured in the Installer Settings section. The 3020 is a single stage
thermostat and not intended for multi stage equipment.
Conventional Systems
NOTE: Additional options are configured in the
Installer Settings section.
S1
S2
NOTES - Additional Wiring Options
[1]Theseterminalscanbeusedtoconnecta
Braeburn
®
indoororoutdoorremotesensor.
Additional Wiring Options
IndoororOutdoorRemoteSensor[note 1]
Hydronic Heat Only
Set System Type to 1HD
Rh
24VoltACPower(heatingtransformer)
W1 ZoneValvePowerOpen
V3 ZoneValvePowerClose
G FanRelay[note 4]
C 24VoltACTransformerCommon[note 1]
Hydronic Heat / 1 Cool
Set System Type to 11HD
Rh
24VoltACPower(heatingtransformer)[note 2]
Rc
24VoltACPower(coolingtransformer)[note 2]
W1 ZoneValvePowerOpen
V3 ZoneValvePowerClose
Y1 CompressorRelay
G FanRelay(coolingfanonly)
C 24VoltACTransformerCommon[note 1, 3]
Installer Guide 6
1 HEAT / 1 COOL - No Auxiliary Heat
Set System Type to 11HP
Rh 24VoltACPower
Rc ConnectedtoRhwithsuppliedJumperWire
O/B
ChangeoverValve [note 2]
Y1 CompressorRelay
G FanRelay
C 24VoltACTransformerCommon [note 1]
3 HEAT / 2 COOL – Including Auxiliary Heat
Set System Type to 32HP
Rh 24VoltACPower
Rc
ConnectedtoRhwithsuppliedJumperWire
O/B ChangeoverValve [note 2]
Y1
Compressor1Relay(1ststageheating/cooling)
Y2
Compressor2Relay(2ndstageheating/cooling)
E/W3
AuxiliaryHeatRelay(3rdstageheating)[note 5]
G FanRelay
C 24VoltACTransformerCommon[note 1]
L OptionalSystemFaultMonitor[note 4]
2 HEAT / 1 COOL - Including Auxiliary Heat
Set System Type to 22HP
Rh 24VoltACPower
Rc ConnectedtoRhwithsuppliedJumperWire
O/B
ChangeoverValve[note 2]
Y1 CompressorRelay(1ststageheating/cooling)
W2
AuxiliaryHeatRelay(2ndstageheating)[note 3]
E EmergencyHeatRelay[note 3]
G FanRelay
C 24VoltACTransformerCommon[note 1]
L OptionalSystemFaultMonitor[note 4]
2 HEAT / 2 COOL - No Auxiliary Heat
Set System Type to 32HP
Rh 24VoltACPower
Rc ConnectedtoRhwithsuppliedJumperWire
O/B
ChangeoverValve[note 2]
Y1
Compressor1Relay(1ststageheating/cooling)
Y2
Compressor2Relay(2ndstageheating/cooling)
G FanRelay
C 24VoltACTransformerCommon[note 1]
L OptionalSystemFaultMonitor[note 4]
NOTES - Heat Pump Systems
[1] Optional24VoltACcommonconnection.
[2] O(coolactive)orB(heatactive)isselectedin
theInstallerSettingsmenu.
[3] Installaeldsuppliedjumperbetweenthe
W2andW1/E/W3terminalsifthereis
noseparateemergencyheatrelayinstalled.
[4] IftheLterminalisused,the24VoltACcommon
mustbeconnected(Cterminal).
[5] Ifaseparateemergencyheatrelayisinstalled,the
W1/E/W3terminalshouldhaveboththeauxiliary
heat1relayandemergencyheatrelayconnected.
Provide disconnect and overload protection as required.
Typical Wiring Congurations
NOTE: The “System Type” option will be configured in the Installer Settings section. The 3020 is a single
stage thermostat and not intended for multi stage equipment.
Heat Pump Systems
NOTE: Additional options are configured in the
Installer Settings section.
S1
S2
NOTES - Additional Wiring Options
[1]Theseterminalscanbeusedtoconnecta
Braeburn
®
indoororoutdoorremotesensor.
Additional Wiring Options
IndoororOutdoorRemoteSensor[note 1]
INSTRUCTIONS
7 Installer Guide
NOTE: This thermostat ships congured as a 1H/1C conventional
thermostat. Conrm installer settings. See page 9.
UP
UP
4
Attach Thermostat to Sub-Base
3) InsertQuickReferenceCardintoslot
ontopofthermostat.
1) Lineupthethermostatbodywiththesub-base.
2) Carefullypushthethermostatbodyagainstthe
sub-baseuntilitsnapsinplace.
Installer Guide 8
INSTRUCTIONS
Room Temperature...................... Displaysthecurrentroomtemperature
Set Temperature.......................... Displaysthecurrentsetpointtemperature
Reset Button ...............................Resetscurrenttime,programandusersettings
SYSTEM Button............................ Selectsthesystemyouwanttocontrol
BACK Button................................. Movesbackininstaller/usersetupmodes
NEXT Button.................................Movesforwardininstaller/usersetupmodes
RETURN Button............................Returnstonormalmodefrominstaller/usersetupmodes
Service Indicators ...................... Displaysvariousservice/maintenanceinformation
FAN Button................................... Selectsthesystemfanmode
Quick Reference Instructions...... Storedinslotlocatedattopofthermostat
Low Battery Indicator.................. Indicateswhenthebatteriesneedtobereplaced
Fan Indicator................................ Indicateswhenthesystemfanisrunning
System Status Indicator ............. Displaysinformationaboutthestatusofthesystem
Lock Mode Indicator ................... Indicatesifthethermostatislocked
SpeedBar
®
...................................Increasesordecreasessettings(time,temperature,etc.)
Outdoor Temperature Indicator....
Displaysalongwiththeoutdoortemperaturereading(seenotebelow)
Battery Compartment ................. Locatedinthebackofthermostat
3
Quick Reference
1
2
3
5
15
7
14
16
13
12
11
10
1
2
3
4
5
6
7
8
9
10
11
Thermostat and Display
12
13
14
6
8
4 9
15
16
NOTE: If a Braeburn
®
outdoor sensor was connected you can view the outdoor temperature by
pressing the BACK and NEXT buttons at the same time.
INSTRUCTIONS
TheInstallerSettingsmustbeproperlyconguredinorderforthisthermostattooperatecorrectly.TheInstaller
Settingsaremenudriven.Theportionofthesesettingsthatdonotapplytoyoursetupwillbeskipped.These
settingsareindicatedbelowwithcomments.Moredetailoneachsettingfollowsthistable.
1. PressandholddowntheRETURNand
buttonsfor3seconds.
2. Releasebothbuttonsandtherstinstaller
settingwillbedisplayed.
3. Changesettingsasrequiredusingthe
orportionoftheSpeedBar
®
.
4. PressNEXTorBACKtomovetothenext
orprevioussetting,pressRETURNtoexit.
No. Installer Setting Factory Setting Comments
(
Notes follow this table) Default Options (More information follows this table)
1 TemperatureScale F DEG F DEG SelectforFahrenheitdisplay
C DEG SelectforCelsiusdisplay
2 AutoChangeover oF AUTO oF AUTO DisablesAutoChangeovermode
ON AUTO EnablesAutoChangeovermode
11CONV Selectfor1H/1CConventionalsystem
22CONV Selectfor2H/2CConventionalsystem
3 SystemType 11CONV 11HP Selectfor1H/1CHeatPumpsystem
22HP Selectfor2H/2CHeatPumpsystem
32HP Selectfor3H/2CHeatPumpsystem
1HD SelectforHeatOnlyHydronicsystem
11HD SelectforHydronicHeat/1Csystem
4 1stStageDifferential 0.5 DIF1 0.5, 1.0or Selecta1ststagetemperaturedifferentialof.5°,
2.0 DIF1 1°or2°F(0.2°,0.5°or1°C)
5 2ndStageDifferential 2.0 DIF2 1.0, 2.0, 3.0, Selecta2ndstagetemperaturedifferentialof1°,
[note 1] 4.0, 5.0or 2°,3°,4°,5°or6°F(0.5°,1°,1.5°,2°,2.5°or3°C)
6.0 DIF2
6 3rdStageDifferential 2.0 DIF3 1.0, 2.0, 3.0, Selecta3rdstagetemperaturedifferentialof1°,2°,
[note 1] 4.0, 5.0or
3°,4°,5°or6°F(0.5°,1°,1.5°,2°,2.5°or3°C)
6.0 DIF3
7 1stStageFanControl HG FAN 1 HG FAN 1 Selectfor1ststageGasheating
[note 2] HE FAN 1 Selectfor1ststageElectricheating
8 EmergencyHeat] HE EMER HE EMER SelectforElectricEmergencyHeat
FanControl[note 3] HG EMER SelectforGasEmergencyHeat
9 ReversingValve REVO REVO SelectforcoolactiveReversingValve(Oterminal)
(O/BTerminal)[note 4] REVB SelectforheatactiveReversingValve(Bterminal)
10 FossilFuel AE AUX AE AUX SelectforElectricAuxiliaryheat(withcompressor)
BackupHeat[note 3] AG AUX SelectforGasAuxiliaryheat(withoutcompressor)
4
Installer Settings
9 Installer Guide
NOTE: Shaded areas below do not apply to the 3020.
No. Installer Setting Factory Setting Comments
(
Notes follow this table) Default Options (More information follows this table)
11
CompressorPowerOutage
oF CPOP oF CPOP DisablesPowerOutageLockoutDelay
Protection [notes 3, 5] on CPOP EnablesPowerOutageLockoutDelay
12 ACPowerInterrupt
AC oF MONR
AC oF MONR DisablesACPowerInterruptWarning
Warning[note 5] AC on MONR EnablesACPowerInterruptWarning
13 CompressorShort 5 CSCP 5, 4, 3, 2or Selectacompressorshortcycleprotectiondelayof5,
CycleProtection[note 6] 0 CSCP 4,3,2or0minutes
14 ResidualCooling 60 FAN 90, 60, 30 SelectaResidualCoolingFanDelayof90,60,
FanDelay[note 6] or0 FAN 30or0seconds.
15 IndoorRemoteSensor I SENS I SENS Temperatureissensedfromthermostatonly.
Control*[note 7] E SENS Temperatureissensedfromremotesensoronly.
A SENS Temperatureiscombinedwiththethermostatand
theremotesensor.
16 LockoutSecurityLevel 2 LOCK 2 LOCK Iflocked–Completelockoutisenabled
1 LOCK Iflocked–Partiallockoutisenabled(SpeedBar
®
is
stillfunctional)
17 AutoChangeover 3 BAND 2, 3, 4or5 SelectaDeadBandof2°,3°,4°or5˚F
DeadBand[note 8] BAND (1°,2°or3°C)forAutoChangeovermode.
18 CompressorBalance NO BALC NO BALC DisablesBalancePoints
Point[notes 3, 9] 15-50 BALC SelectaCompressorBalancePointof15°-50°F
(-9°-10°C)
19 AuxiliaryHeatBalance NO BALA NO BALA DisablesBalancePoints
Point[notes 3, 9]
70-40 BALA
SelectaAuxiliaryHeatBalancePointof70°-40°F
(21°-4°C)
20
HeatSetPointUpperLimit
90LIM 90-60 LIM
SelectaHeatSetPointUpperLimitof90°-60°F(32°-10°C)
21
CoolSetPointLowerLimit
45LIM 45-80 LIM
SelectaCoolSetPointLowerLimitof45°-80°F(7°-27°C)
[note 6]
*WhenaBraeburn
®
outdoorsensorisconnected,thethermostatautomaticallyrecognizesit.PressBACKandNEXTatthesame
timetodisplayoutdoortemperature.
NOTE: Additional options such as Service Monitors, Setting the lock code, etc. are located in the User Settings –
See User manual for information on setting these options.
NOTES - Installer Settings
1 Onlyavailableifa2or3stagesystemtypewasselectedinoption3.
2 OnlyavailableifaConventionalsystemwasselectedinoption3.
3 Onlyavailableifa2or3stageHeatPumpsystemwasselectedinoption3.
4 OnlyavailableifaHeatPumpsystemwasselectedinoption3.
5 Onlyavailableifthe24VoltACcommonwireisconnectedtotheCterminal.
6 NotavailableifaHeatOnlyHydronicsystemisselectedinoption3.
7 OnlyavailableifaBraeburn®indoorremotesensorwasconnected.
8 Onlyavailableifautochangeoverwasenabledinoption2.
9 OnlyavailableifaBraeburnoutdoorsensorwasconnected.
Detailed Explanation of Installer Settings (also see NOTES above):
1 Temperature Scale–Selectsatemperaturescaleofeither°For°C.
2 Auto Changeover–Selectsautochangeoveronoroff.Whenautochangeovermodeisenabledand
selected,thesystemautomaticallyswitchesbetweenheatingandcoolingmodes.Thereisa5minutedelay
whenswitchingfromheatingtocoolingorcoolingtoheatinginautochangeovermode.
NOTE: Also see “Auto Changeover Dead Band” in option 17.
Installer Guide 10
3 System Type–Selectsthesystemtypeforyourinstallation.NOTE: Changes made to this option will reset
options 4 through 11 back to their default values dependant on the system type.
4 1st Stage Differential–Selectsa1ststagetemperaturedifferential.
5 2nd Stage Differential [note 1]–Selectsa2ndstagetemperaturedifferential.
6 3rd Stage Differential [note 1]–Selectsa3rdstagetemperaturedifferential.
7 1st Stage Fan Control [note 2]–Selectsa1ststagefancontrolofeithergasorelectricheat.
8 Emergency Heat Fan Control [note 3]–Selectsemergencyheatfancontrolofeithergasorelectricheat.
9 Reversing Valve [note 4]–SelectstheoutputstateoftheO/Bterminal.SelectOforthisterminaltobe
activeinthecoolmodeorselectBforthisterminaltobeactiveintheheatmode.
10 Auxiliary Fossil Fuel Heat Pump Control [note 3]–Whensettoelectric(AEAUX),boththecompressor
(1ststage)andauxiliarystage(s)willrunwhenacallforauxiliaryheatismade.Whensettogas(AGAUX),
thecompressorstage(s)willbelockedoutoneminuteafteracallforauxiliaryheat.NOTE: This option can
be overridden if setting an auxiliary heat balance point in Option 19.
11 Compressor Power Outage Protection [notes 3, 5]–Selectspoweroutageprotectiononoroff.When
enabled,thisthermostatwillprovidecoldweathercompressorprotectionbylockingoutthecompressor
stage(s)ofheatingforaperiodoftimeafterapoweroutagegreaterthan60minutes.
12 AC Power Interrupt Warning [note 5]–Whenenabled,thethermostatwilldisplayanoutagewarning
whenACpowertothethermostatislost.
13 Short Cycle Protection [note 6]–Selectsthenumberofminutesthecoolingcompressorwillbelocked
outafterturningoff.Thisshortcycleprotectionisalsoactiveintheheatmodeifaheatpumpsystemwas
selectedinOption3.
14 Residual Cooling Fan Delay [note 6]–Selectsadelayforthesystemfanafterthecoolingcompressor
hasturnedoff.Thisdelaywillhelpremovetheremainingcoolairoutoftheductworkprovidingadditional
efciency.
15 Indoor Remote Sensor Control [note 7]–IfaBraeburn
®
indoorremotesensorisconnectedduring
installation,thethermostatwillautomaticallydetectthesensor.Whenanindoorsensorisdetected,youmay
selectbetweenthermostatonly(ISENS),remotesensoronly(ESENS)orcombiningthethermostatandthe
remotesensor(ASENS).NOTE: This option does not apply to a Braeburn outdoor sensor. When an outdoor
sensor is connected the thermostat automatically recognizes it and no further configuration is necessary.
16 Lockout Security Level–Selectsthelevelofkeypadlockoutwhenthethermostatislocked.Level2locks
theentirethermostat(includingthefrontresetbutton).Level1lockseverythingexcepttheSpeedBar
®
allowingforupanddowntemperatureadjustment.NOTE: The lock code is set in the User Settings mode
(see User Manual).
17 Auto Changeover Dead Band [note 8]–Whenautochangeovermodeisenabledinoption2and
selected,thesystemautomaticallyswitchesbetweenheatingandcoolingwhentheroomtemperature
meetsthenormalcriteriaforeitheraheatingorcoolingcall.Thereisaforcedseparation(deadband)
betweentheheatingandcoolingsetpointssothatthesystemsdonotworkagainsteachother.This
optionselectstheamountofthisdeadbandindegreeswiththedefaultbeing3°F.
18 Compressor Balance Point [notes 3, 9]–Locksouttheuseofthecompressorheatstagewhenthe
outsideairtemperatureislessthantheselectedsettingof15°Fto50°F(-9°Cto10°C).
19 Auxiliary Heat Balance Point [notes 3, 9]–Locksouttheuseoftheauxiliaryheatstagewhenthe
outsideairtemperatureexceedstheselectedsettingof70°Fto40°F(21°Cto4°C).NOTE: This balance
point overrides the fossil fuel compressor lockout in option 10. If this option is set to gas and the outdoor
temperature is over the auxiliary balance point, the compressor will remain on during a call for auxiliary heat.
11 Installer Guide
12 Installer Guide
20 Heat Set Point Upper Limit–Selectstheheatingsetpointupperadjustmentlimit.
21 Cool Set Point Lower Limit [note 6]–Selectsthecoolingsetpointloweradjustmentlimit.
Warning
Read Before Testing
• Donotshort(orjumper)acrossterminalsonthegasvalveorattheheatingorcoolingsystemcontrolboard
totestthethermostatinstallation.Thiscoulddamagethethermostatandvoidthewarranty.
• DonotselecttheCOOLmodeofoperationiftheoutsidetemperatureisbelow50ºF(10ºC).Thiscould
possiblydamagethecontrolledcoolingsystemandmaycausepersonalinjury.
• Thisthermostatincludesanautomaticcompressorprotectionfeaturetoavoidpotentialdamagetothe
compressorfromshortcycling.Whentestingthesystem,makesuretotakethisdelayintoaccount.
NOTE: The compressor delay can be bypassed by pressing the reset button on the front of the thermostat.
All user settings will be returned to factory default, however all Installer settings will remain as originally
programmed in section 4.
1 PresstheSYSTEMbuttonuntilthethermostatisinHEATmode.
2 UsingtheSpeedBar
®
raisethesettemperatureaminimumof3degreesabovethecurrentroom
temperature.Thesystemshouldstartwithinafewseconds.Withagasheatingsystem,thefanmay
notstartrightaway.
3 PressSYSTEMuntilthethermostatisintheOFFmode.Allowtheheatingsystemtofullyshutdown.
4 PressSYSTEMuntilthethermostatisintheCOOLmode.
5 UsingtheSpeedBarlowerthesettemperatureaminimumof3degreesbelowthecurrentroom
temperature.Thesystemshouldstartwithinafewseconds(unlesscompressorshortcycleprotection
isactive–Seenoteabove).
6 PressSYSTEMuntilthethermostatisintheOFFmode.Allowthecoolingsystemtofullyshutdown.
7 PressFANuntilthethermostatisinFANONmode.Thesystemfanshouldstartwithinafewseconds.
8 PressFANuntilthethermostatisinFANAUTOmode.Allowthesystemfantoturnoff.
5
System Testing
®
Store this manual for future reference.
Limited Warranty
Wheninstalledbyaprofessionalcontractor,thisproductisbackedbya5yearlimited
warranty.Limitationsapply.Forlimitations,termsandconditions,youmayobtainafull
copyofthiswarranty:
·Visitusonline:www.braeburnonline.com/warranty
·Phoneus:866.268.5599
·Writeus:BraeburnSystemsLLC
2215CornellAvenue
Montgomery,IL60538
5
YEAR
WARRANT Y
LIMITED
BraeburnSystemsLLC
2215CornellAvenue•Montgomery,IL60538
TechnicalAssistance:www.braeburnonline.com
Callustoll-free:866-268-5599(U.S.)
630-844-1968(OutsidetheU.S.)
©2013BraeburnSystemsLLC•AllRightsReserved•MadeinChina.
®
3020W-100-02
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13

Braeburn Systems Braeburn 3020 3220 Wall Thermostat User manual

Category
Heat pumps
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI