  • Hello! I am an AI chatbot trained to assist you with the Braeburn Braeburn 1025NC Wall Thermostat User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
This thermostat requires 24 Volt AC Power or two (2) properly installed
“AA Alkaline batteries for proper operation. When connecting 24 Volt
AC Power the batteries may be installed as a backup.
For use only as described in this manual. Any other use
will void warranty.
1025NC
Single Stage Heat Only
1
Specifications
2
About Your Thermostat
3
Installation
4
System Testing
5
Setting User Options
6
Operating Your Thermostat
7
Thermostat Maintenance
®
Warning
Turn off power to the heating equipment
before installation.
Attention
For installation by experienced service
technicians only.
Read all instructions before proceeding.
This thermostat is compatible with:
• Singlestageheatonlysystems
• 250–750millivoltheatonlysystems
• 2or3wirehydroniczonesystems
Electrical and control specifications:
•ElectricalRating:24VoltAC
•1ampmaximumloadperterminal
•ACPower:18–30VoltsAC
•DCPower:3.0VoltDC(2“AA”AlkalineBatteriesIncluded)
•ControlRange:45°–90°F(7°–32°C)
•TemperatureAccuracy:+/-1°F(+/-.5°C)
Terminations
•1025NC–R,G,W1,V3,C
1
Specifications
1025NCW-100-03
Non-Programmable
Thermostat
Model number is located on back
of thermostat
Detailed
User Guide
2
Single Stage Heat Only
5
Setting User Options
6
Operating Your Thermostat
7
Thermostat Maintenance
For installation by experienced service
technicians only.
2
About Your Thermostat
Room Temperature........... Displaysthecurrentroomtemperature
Reset Button.....................
Resetsthermostatbacktofactorydefaults
Low Battery Indicator...... Indicateswhenthebatteriesneedto
bereplaced
System Switch..................Selectsheatonoroff
Quick Reference
Instructions......................Storedinslotattopofthermostat
Fan Indicator.................... Indicateswhenthesystemfanisrunning
System Status Indicator...Displaysinformationaboutthestatusof
 thesystem
Arrow Buttons.................. Usedtoincreaseordecreasesettings
Set Temperature...............Displaysthecurrentsetpointtemperature
Fan Switch........................Selectsthesystemfanmode
Battery Compartment....... Locatedinthebackofthethermostat
1
2
3
4
5
1
2
3
3
Installation
Warning
Disconnect power before beginning installation.
Thermostat Location
Installthethermostatapproximately5feet(1.5m)abovetheoorinan
areathathasagoodamountofaircirculationandmaintainsanaverage
roomtemperature.
Avoidinstallationinlocationswherethethermostatcanbeaffectedby
drafts,deadairspots,hotorcoldairducts,sunlight,appliances,concealed
pipes,chimneysandoutsidewalls.
7
5
6
8
9
6
7
8
Model number is located on back
of thermostat
10
9
4
10
3
Install your new Braeburn thermostat in 5 basic steps:
1 InstalltheSub-Base
2 ProvidePower
3 ConnectYourWires
4 SetInstallerSwitches
5 AttachThermostattoSub-Base
Install the Sub-Base:
•Removethesub-basefromthebodyofthethermostat.
•Mountthesub-baseasshownbelow:
1
Drill 3/16” pilot holes in
your desired location.
Use supplied anchors for
drywall or plaster.
NOTE: After sub-base installation, you may insert the quick reference card
into the slot on the top of the base.
Provide Power
•For 24 Volt AC power,youmustconnectthecommonsideofthetrans-
formertotheCterminalonthethermostatsub-base.
•For primary or back-up power,insertthe2supplied“AAtypealkaline
batteriesintothebatterycompartmentlocatedintherearhousingofthe
thermostat.MakesuretopositionthePositive(+)andNegative(-)sides
ofthebatteriescorrectlywiththe+/-symbolsinthebatterycompartment.
24VAC Power
Terminal (C)
2
UP UP
C
4
Terminal Function Description
R Input PowerConnection(24VoltACHeating
 TransformerorMillivoltPowerSource)
G Output FanControl
W1 Output ConventionalHeatControl
V3 Output ZoneValvePowerClose
C Input 24VoltACTransformerCommon
Connect Your Wires
3
Wiring Terminations
Heat Only or Millivolt
R PowerConnection
W1 HeatRelay
G FanControl [note 3]
C 24VoltACTransformerCommon[note 2]
Typical Wiring Configurations
Conventional Systems
5
NOTES - Conventional Systems
[1]Fora2-wirezonevalveyouwillnotconnectV3
[2]Ifbatteriesareinstalled,the24VoltACcommonconnectionisoptional
[3]Ifneededforsystem
Provide disconnect and overload protection as required.
3 Wire Hydronic Zone Valve
R
PowerConnection
W1
ZoneValvePowerOpen
V3 ZoneValvePowerClose[note 1]
G FanControl [note 3]
C 24VoltACTransformerCommon[note 2]
Typical Wiring Configurations
Conventional Systems (cont.)
Factory Setting
Switch Default Options Comments
6
F/C F
HE/HG HG
Set Installer Switches
4
F Selectforfahrenheittemperaturescale
C Selectforcelsiustemperaturescale
 HG Selectforgasheatorhydronicsystems
  withoutfan
 HE Selectforelectricheatorhydronic
  systemswithfan
Attach Thermostat to Sub-Base
5
1.Lineupthethermostatbodywiththesub-base.
2.Carefullypushthethermostatbodyagainstthesub-baseuntilitsnaps
intoplace.
3.Insertquickreferencecardintoslotontopofthermostat.
NOTE: The reset button should be pressed after making any changes to the
installer switches.
UP UP
7
4
System Testing
Warning
Read Before Testing
• Donotshort(orjumper)acrossterminalsonthegasvalveoratthe
 systemcontrolboardtotestthethermostatinstallation.Thiscould
damagethethermostatandvoidthewarranty.
1 MovetheSYSTEMswitchtoONmode.
2 Presstoraisethesettemperatureaminimumof3degreesabove
thecurrentroomtemperature.Thesystemshouldstartwithinafew
seconds.Withagasheatingsystem,thefanmaynotstartrightaway.
3 MovetheSYSTEMswitchtotheOFFmode.Allowtheheatingsystemto
fullyshutdown.
4 MovetheFANswitchtotheONmode.Thesystemfanshouldstart(on
systemswhereafanisinstalled)withinafewseconds.
5 MovetheFANswitchtotheAUTOmode.Allowthesystemfanto
turnoff.
5
Setting User Options
Advanced User Options
Useroptionsallowyoutocustomizesomeofyourthermostatsfeatures.
Thedefaultuseroptionsarecompatiblewithmostapplications,thereforeit
isnotrequiredthatyouadjustthem.
To access the User Options menu, hold down both the and buttons
for approximately 3 seconds until the screen changes and displays
the User Option.
PresstheorbuttontochangethesettingforthedisplayedUserOption.
Afteryouhavemadeyourdesiredsetting,pressandtogetherto
returntothenormalmode.
Thethermostatwillalsoreturntonormalmodeafteryourlastuseroption
ismadeorafternokeyshavebeenpressedfor15seconds.
8
User Factory Setting
No. Options Default Options Comments
1 1ststage
0.5
0.5, 1.0
Selecta1ststagetemperature
differential
or 2.0 differentialof.5˚,1˚or2˚F(.25˚,5˚
or2˚C)
Table of User Options
Detailed Explanation of User Options:
Temperature Differential
Thedifferentialsettingisthetemperaturecontrolrangethatyourthermostat
willprovide.Thesmallerthesetting,thetighteryourrangeoftemperature
controlandcomfortwillbe.
6
Operating Your Thermostat
Setting the System Control Mode
TheSystemControlhastwomodesofoperation–OFFandHEAT.Themodecan
beselectedbymovingtheSYSTEMswitchtotheappropriateposition.
OFF Heatingsystemisoff.
HEAT Yourheatingsystemwilloperate.
Setting the Fan Control Mode
The Fan Control has 2 modes of operation – AUTO
and ON. The mode can be selected by moving the
FAN switch to the appropriate position.
AUTO Thefanwillrunwhenrequiredby
thesystem.
ON Thefanwillruncontinually.
NOTE: Some system types do not have a fan control mode.
9
Detailed Explanation of User Options:
Temperature Differential
Thedifferentialsettingisthetemperaturecontrolrangethatyourthermostat
willprovide.Thesmallerthesetting,thetighteryourrangeoftemperature
controlandcomfortwillbe.
Temperature Adjustment
Presstheorbuttontoadjustthecurrentsetpointtemperature.
Status Indicators
Statusindicatorsappearinthedisplaytolet
youknowifyoursystemisonoroff.
HEAT ON
Indicatesyourheatingsystemisrunning.
Resetting the Thermostat
Thisthermostatprovidesyouwitharesetbuttonthatwilleraseallofyour
usersettings.
Toresetthethermostat,useasmallobjectsuchasatoothpickorpaper-
clipandgentlypressthebuttonlocatedinsidethesmallholeonthefrontof
thethermostathousinglabeled“reset”.
7
Thermostat Maintenance
Changing the Batteries
Dependingonyourparticularinstallation,this
thermostatmaybeequippedwithtwo(2)“AA”
typealkalinebatteries.
If batteries are installed and they become low,
a low battery indicator will appear in the display.
You
shouldchangeyourbatteriesimmediately
whenyouseethelowbatterysignalbyfollowing
theseinstructions.
NOTE: We recommend replacing the thermostat batteries annually or if the
thermostat will be unattended for an extended period of time.
1.Removethermostatbodybygentlypullingitfrombase.
2.Removeoldbatteriesandreplacewithnewbatteries.
3.Makesuretocorrectlypositionthe(+)and(-)symbols.
4.Gentlypushthermostatbodybackontobase.
Thermostat Cleaning
Neversprayanyliquiddirectlyonthethermostat.Usingasoftdampcloth
wipetheouterbodyofthethermostat.Neveruseanyabrasivecleansersto
cleanyourthermostat.
For troubleshooting tips, visit braeburnonline.com.
BraeburnSystemsLLC
2215CornellAvenue•Montgomery,IL60538
TechnicalAssistance:www.braeburnonline.com
Callustoll-free:866-268-5599(U.S.)
630-844-1968(OutsidetheU.S.)
©2014BraeburnSystemsLLC•AllRightsReserved•MadeinChina.
®
Store this manual for future reference.
1025NCW-100-03
Limited Warranty
Wheninstalledbyaprofessionalcontractor,thisproductisbackedbya5year
limitedwarranty.Limitationsapply.Forlimitations,termsandconditions,you
mayobtainafullcopyofthiswarranty:
·Visitusonline:www.braeburnonline.com/warranty
·Phoneus:866.268.5599
·Writeus:BraeburnSystemsLLC
2215CornellAvenue
Montgomery,IL60538
+
+
5
YEAR
WARRANTY
LIMITED
/