7
User Factory Setting
No. Options Default Options Comments
1
Programming
PRO 7 PRO 7
Selectfor7DayProgrammingMode
Mode PRO 52 Selectfor5-2DayProgrammingMode
PRO NO SelectforNon-ProgrammableMode
2 1ststage
0.5
0.5, 1.0,
Selecta1ststagetemperature
differential
2.0 differentialof.5˚,1˚or2˚F(0.2˚,
0.5˚or1˚C)
3
2ndstage
2.0
1.0, 2.0,
Selecta2ndtemperature
differential
3.0, 4.0
, differentialof1˚,2˚,3˚,4˚,5˚or6˚F
(2220Only)
5.0, 6.0
(.5˚,1˚,1.5˚,2˚,2.5˚or3˚C)
LNG
Selectslong(permanent)holdmode
24HRS
Selects24hr.(temporary)holdmode
5
OFF
Disableslterservicemonitorfeature
30, 60, 90
, Selectsanumberofdaysbefore
120, 180, thethermostatwillashaService
365 Filterreminderinthedisplay.
6 OF REC Disablesadaptive(early)
recoverymode
ON REC Enablesadaptive(early)
recoverymode
Table of User Options
Detailed Explanation of User Options:
Programming Mode
(User Option 1)
Selectstheprogrammingmode(choosefrom7day,5-2Day(weekday/
weekend)programmingornon-programmable.
Temperature Differential
(User Option 2 and 3)
Thedifferentialsettingisthetemperaturecontrolrangethatyourthermostat
willprovide.Thesmallerthesetting,thetighteryourrangeoftemperature
controlandcomfortwillbe.The2ndstagedifferentialisonlyforsystems
withasecondstageofheating(auxiliaryheat).
5
Setting User Options
Advanced User Options
Useroptionsallowyoutocustomizesomeofyourthermostat’sfeatures.
Mostuserswillnotneedtomakeanychangestothesettingsinthissection.
To enter the User Options menu, hold down the RETURN button
for
approximately 3 seconds until the screen changes and displays the
first User Option.
PresstheorbuttontochangethesettingforthedisplayedUserOption.
Afteryouhavemadeyourdesiredsetting,pressRETURNtoadvancetothe
nextUserOption.
Thethermostatwillreturntonormalmodeafteryourlastuseroptionis
madeorafternokeyshavebeenpressedfor15seconds.
Extended
HoldPeriod*
Filter
Service
Monitor
LNG
Adaptive
Recovery
Mode(ARM
TM
)*
OF REC
OFF
4