Crown Audio CE SERIES User manual

Category
Supplementary music equipment
Type
User manual
Operation Manual
CE 1000
Obtaining Other Language Versions:
To obtain information in another language about the use of this product, please contact your
local Crown Distributor. If you need assistance locating your local distributor, please contact Crown at 574-294-8000.
This manual does not include all of the details of design, production, or variations of the equipment. Nor does it cover every possible
situation which may arise during installation, operation or maintenance.
The information provided in this manual was deemed accurate as of the publication date. However, updates to this information may have
occurred.
To obtain the latest version of this manual, please visit the Crown website at www.crownaudio.com.
Trademark Notice:
Crown and Amcron are registered trademarks of Crown International. Other trademarks are the property of their
respective owners.
Some models may be exported under the name Amcron.
®
©2003 by Crown Audio Inc., P.O. Box 1000, Elkhart, Indiana 46515-1000 U.S.A. Telephone: 574-294-8000
125645-8
8/03
CE Series
CE 2000
Operation Manual
CE Series Power Amplifiers
page 2
1) Read these instructions.
2) Keep these instructions.
3) Heed all warnings.
4) Follow all instructions.
5) Do not use this apparatus near water.
6) Clean only with a dry cloth.
7) Do not block any ventilation openings. Install
in accordance with the manufacturer’s instruc-
tions.
8) Do not install near any heat sources such as
radiators, heat registers, stoves, or other
apparatus that produce heat.
9) Do not defeat the safety purpose of the polar-
ized or grounding-type plug. A polarized plug
has two blades with one wider than the other.
A grounding-type plug has two blades and a
third grounding prong. The wide blade or the
third prong is provided for your safety. If the
provided plug does not fit into your outlet,
consult an electrician for replacement of the
obsolete outlet.
10) Protect the power cord from being walked on
or pinched, particularly at plugs, convenience
receptacles, and the point where they exit from
the apparatus.
11) Only use attachments/accessories specified
by the manufacturer.
12) Use only with a cart, stand, bracket, or table
specified by the manufacturer, or sold with the
apparatus. When a cart is used, use caution
when moving the cart/apparatus combination
to avoid injury from tip-over.
13) Unplug this apparatus during lightning storms
or when unused for long periods of time.
14) Refer all servicing to qualified service person-
nel. Servicing is required when the apparatus
has been damaged in any way, such as power-
supply cord or plug is damaged, liquid has
been spilled or objects have fallen into the
apparatus, the apparatus has been exposed to
rain or moisture, does not operate normally,
or has been dropped.
15) To reduce the risk of fire or electric shock, do
not expose this apparatus to rain or moisture.
TO PREVENT ELECTRIC SHOCK DO NOT REMOVE
TOP OR BOTTOM COVERS. NO USER SERVICE-
ABLE PARTS INSIDE. REFER SERVICING TO
QUALIFIED SERVICE PERSONNEL.
À PRÉVENIR LE CHOC ÉLECTRIQUE N’ENLEVEZ
PAS LES COUVERCLES. IL N’Y A PAS DES PAR-
TIES SERVICEABLE À L’INTÉRIEUR. TOUS REPA-
RATIONS DOIT ETRE FAIRE PAR PERSONNEL
QUALIFIÉ SEULMENT.
IMPORTANT
CE Series amplifiers require Class 2 output wiring.
MAGNETIC FIELD
CAUTION! Do not locate sensitive high-gain equip-
ment such as preamplifiers or tape decks directly
above or below the unit. Because this amplifier has
a high power density, it has a strong magnetic field
which can induce hum into unshielded devices that
are located nearby. The field is strongest just above
and below the unit.
If an equipment rack is used, we recommend locat-
ing the amplifier(s) in the bottom of the rack and the
preamplifier or other sensitive equipment at the top.
WATCH FOR THESE SYMBOLS:
The lightning bolt triangle is used to alert the user
to the risk of electric shock.
The exclamation point triangle is used to alert the
user to important operating or maintenance instruc-
tions.
Important Safety
Instructions
FCC COMPLIANCE NOTICE
This device complies with part 15 of the FCC rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
CAUTION: Changes or modifications not expressly approved by the party responsible for
complicance could void the user’s authority to operate the euqipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or televi-
sion reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
page 3
CE Series Power Amplifiers
Operation Manual
DECLARATION of CONFORMITY
Crown International, Inc.
TCF Technical Certificate No: C975CRI1.ABS
Sue Whitfield
574-294-8289
European Representative's Name and Address:
Nick Owen
19 Clos Nant Coslech
Pontprennau
Cardiff
CF23 8ND United Kingdom
Competent Body’s Name and Address:
Technology International (Europe) Limited
41-42 Shrivenham Hundred Business Park,
Shrivenham, Swindon, Wilts, SN6 8TZ
Equipment Type: Commercial Audio Power Amplifiers
Family Name: CE1000, CE2000, CE2000TX
Model Names: CE1000 Series, CE2000 Series, CE2000TX Series
EMC Standards:
EN 55103-1:1995 Electromagnetic Compatibility - Product Family Standard for Audio, Video, Audio-Visual and Entertainment Lighting Control Apparatus for Professional Use, Part 1: Emissions
EN 55103-1:1995 Magnetic Field Emissions-Annex A @ 10 cm and 1 M
EN 61000-3-2:1995+A14:2000 Limits for Harmonic Current Emissions (equipment input current 16A per phase)
EN 61000-3-3:1995 Limitation of Voltage Fluctuations and Flicker in Low-Voltage Supply Systems Rated Current 16A
EN 55022:1992 + A1: 1995 & A2:1997 Limits and Methods of Measurement of Radio Disturbance Characteristics of ITE: Radiated, Class B Limits; Conducted, Class B
EN 55103-2:1996 Electromagnetic Compatibility - Product Family Standard for Audio, Video, Audio-Visual and Entertainment Lighting Control Apparatus for Professional Use, Part 2: Immunity
EN 61000-4-2:1995 Electrostatic Discharge Immunity (Environment E2-Criteria B, 4k V Contact, 8k V Air Discharge)
EN 61000-4-3:1996 Radiated, Radio-Frequency, Electromagnetic Immunity (Environment E2, criteria A)
EN 61000-4-4:1995 Electrical Fast Transient/Burst Immunity (Criteria B)
EN 61000-4-5:1995 Surge Immunity (Criteria B)
EN 61000-4-6:1996 Immunity to Conducted Disturbances Induced by Radio-Frequency Fields (Criteria A)
EN 61000-4-11:1994 Voltage Dips, Short Interruptions and Voltage Variation
Safety Standard:
EN 60065: 1998 Safety Requirements - Audio Video and Similar Electronic Apparatus
I certify that the product identified above conforms to the requirements of the EMC Council Directive 89/336/EEC as amended by 92/31/EEC, and the Low Voltage Directive 73/23/EES as amended by 93/68/EEC.
Larry Coburn
Signed
Title: Senior Vice President of Manufacturing
Date of Issue: March 28, 2000
Issued By: Crown International, Inc.
1718 W. Mishawaka Road
Elkhart, Indiana 46517 U.S.A.
Technical Construction File Route
Operation Manual
CE Series Power Amplifiers
page 4
Important Safety Instructions .......................................................2
Declaration of Conformity ...........................................................3
1 Welcome .................................................... 5
1.1 Features .........................................................................5
1.2 How to Use This Manual ................................................5
2 Setup ......................................................... 6
2.1 Unpack Your Amplifier ....................................................6
2.2 Install Your Amplifier ......................................................6
2.3 Ensure Proper Cooling ....................................................6
2.4 Choose Input Wire and Connectors .................................7
2.5 Choose Output Wire and Connectors ..............................8
2.6 Wire Your System ...........................................................9
2.6.1 Stereo Mode ...........................................................9
2.6.2 How to Parallel the Inputs .......................................9
2.6.3 Bridge-Mono Mode ................................................10
2.7 Input Sensitivity Switch ...................................................11
2.8 Connect to AC Mains ......................................................11
2.9 Startup Procedure ...........................................................11
3 Operation .................................................... 12
3.1 Precautions .....................................................................12
3.2 Controls, Indicators and Connectors ...............................13
3.3 Front Panel Controls and Indicators ................................14
3.4 Back Panel Controls ........................................................14
4 Advanced Features and Options ......................... 15
4.1 Protection Systems .........................................................15
4.1.1 Bias Servo ..............................................................15
4.1.2 Fault .......................................................................15
4.1.3 Ultrasonic and Radio Frequency Protection ............15
4.1.4 Drive Protection.......................................................15
4.1.5 Compression ..........................................................15
4.1.6 Power Circuit Breaker .............................................15
4.1.7 Proportional-speed Fan ..........................................15
4.2 Advanced Features ..........................................................15
4.2.1 Crown SST Modules ..............................................15
4.2.2 Fault Monitoring .....................................................17
4.3 Options ............................................................................18
4.3.1 Accessories ............................................................18
4.3.2 Alternate Output Connectors ...................................18
4.3.3 Tamper-Resistant Hole Plugs .................................18
4.3.4 Optional 0.775 V Input Sensitivity Setting ..............18
5 Principles of Operation ................................... 19
6 Troubleshooting ............................................ 21
7 Specifications .............................................. 22
8 Service ....................................................... 23
8.1 Worldwide Service ...........................................................23
8.2 US and Canada Service ...................................................23
8.2.1 Service at a US or Canada Service Center ...............23
8.2.2 Factory Service .......................................................23
8.2.3 Factory Service Shipping Instructions ....................23
9 Warranty ..................................................... 24
Crown Factory Service Information Form ....................................27
Table of Contents
page 5
CE Series Power Amplifiers
Operation Manual
1 Welcome
Crown
®
CE Series amplifiers provide profes-
sional audio amplification for a wide range of
applications, including digital cinema. The
amplifiers are very affordable, and feature front-
panel controls for easy setup and use. They can
be removed for security.
Modern power amplifiers are sophisticated
pieces of engineering capable of producing
extremely high power levels. They must be
treated with respect and correctly installed if
they are to provide the many years of reliable
service for which they were designed.
In addition, CE Series amplifiers include a
number of features which require some expla-
nation before they can be used to their maxi-
mum advantage.
Please take the time to study this manual so
that you can obtain the best possible service
from your amplifier.
1.1 Features
Accurate, undistorted sound.
Bridge-mono/stereo mode switch allows
you to set up your amps/speakers in the
configuration that best suits your needs.
Versatile; handles a wide range of speaker
impedances and outputs.
Advanced protection circuitry guards
against shorted outputs, open circuits, DC,
mismatched loads, general overheating,
high-frequency overloads and internal
faults.
Genuine Neutrik
®
Speakon
®
connectors.
Choice of 1/4-inch, XLR or barrier strip
inputs.
Removable front-panel level control
knobs.
Selectable input sensitivity.
Proportional-speed fan optimizes cooling
efficiency.
Can be mounted in EIA standard 19-in.
(48.3-cm) rack, shallow 14-in. (35.5) rack,
or stacked on top of each other.
Three Year, No-Fault, Fully-Transferable
Warranty completely protects your invest-
ment and guarantees its specifications.
Crown’s advance-replacement Profit Pro-
tection Plan provides quick, no-questions-
asked replacement of covered amps.
1.2 How to Use This Manual
This manual provides you with the necessary
information to safely and correctly setup and
operate your amplifier. It does not cover every
aspect of installation, setup or operation that
might occur under every condition. For addi-
tional information, please consult Crown’s
Amplifier Application Guide (available online at
www.crownaudio.com), Crown Technical Sup-
port, your system installer or retailer.
We strongly recommend you read all instruc-
tions, warnings and cautions contained in this
manual. Also, for your protection, please send
in your warranty registration card today. And
save your bill of sale — it’s your official proof
of purchase.
Operation Manual
CE Series Power Amplifiers
page 6
2.1 Unpack Your Amplifier
Please unpack and inspect your amplifier for
any damage that may have occurred during
transit. If damage is found, notify the transpor-
tation company immediately. Only you can ini-
tiate a claim for shipping damage. Crown will
be happy to help as needed. Save the shipping
carton as evidence of damage for the shipper’s
inspection.
We also recommend that you save all packing
materials so you will have them if you ever
need to transport the unit. Never ship the
unit without the factory pack.
YOU WILL NEED (not supplied):
Input wiring cables
Output wiring cables
Rack and rack-mounting hardware for mount-
ing amplifier (or a stable surface for stacking)
WARNING: Before you start to set up
your amplifier, make sure you read and
observe the Important Safety Instruc-
tions found at the beginning of this
manual.
2.2 Install Your Amplifier
CAUTION: Before you begin, make sure
your amplifier is disconnected from the
power source, with power switch in the
“off” position and all level controls
turned completely down (counterclock-
wise).
Use a standard 19-inch (48.3 cm) equipment
rack. See Figure 2.1 for amplifier dimensions.
You may also stack amps without using a
cabinet.
NOTE: When transporting, amplifiers should be
supported at both front and back.
2.3 Ensure Proper Cooling
When using an equipment rack, mount units
directly on top of each other. Close any open
spaces in rack with blank panels. DO NOT
block front or rear air vents. The side walls of
the rack should be a minimum of 2 inches (5.1
cm) away from the amplifier sides, and the back
of the rack should be a minimum of 4 inches
(10.2 cm) from the amplifier back panel.
Figure 2.2 illustrates standard amplifier airflow.
2 Setup
Figure 2.1 CE 1000 and CE 2000 Dimensions
Figure 2.2 Airflow
page 7
CE Series Power Amplifiers
Operation Manual
2.4 Choose Input Wire
and Connectors
You have three choices of input connectors:
1/4-inch (6.35-mm) phone, 3-pin XLR, or
barrier strip. You can also use either balanced or
unbalanced wiring.
Figure 2.3 shows balanced connector pin
assignments for XLR and phone. Figure 2.4
shows unbalanced connector pin assignments
for XLR and phone.
Figure 2.5 shows barrier strip input wiring for a
balanced signal. Both channels should be wired
using a common center terminal for ground con-
nection.
NOTE: Custom wiring should only be
performed by qualified personnel.
Figure 2.3 Balanced Input
Connector Wiring
Figure 2.4 Unbalanced Input
Connector Wiring
2 Setup
Figure 2.5 Barrier Strip Input Wiring:
Balanced Signal In
Operation Manual
CE Series Power Amplifiers
page 8
2.5 Choose Output Wire and Con-
nectors
Crown recommends using pre-built or profes-
sionally wired, high-quality, two- or four-con-
ductor, heavy gauge speaker wires. They should
be terminated with Neutrik Speakon NL4FC con-
nectors (Figure 2.6) at one end and appropriate
connectors to fit your speakers at the other end.
If your CE Series amplifier came equipped with
the CEAS1 (barrier strip) or CEAS2 (5-way bind-
ing post) optional output connectors, you may
wire your output to these connectors instead.
Optional output connectors can also be ordered
as a Service Option for installation on existing
CE Series amplifiers.
If the CEAS1 Output Module is installed, use ter-
minal forks or bare wire for your output connec-
tors (see Figure 2.7).
To prevent the possibility of short-cir-
cuits, replace the cover on the barrier
strip after completing the output wiring.
If the CEAS2 Output Module is installed, connect
to it with bare wires, spade lugs or banana plugs
on the speaker cables (Figure 2.8).
Using the guidelines below, select the appropri-
ate size of wire based on the distance from
amplifier to speaker.
CAUTION: Never use shielded cable for
output wiring.
Distance Wire Size
up to 25 ft. 16 gauge
26-40 ft. 14 gauge
41-60 ft. 12 gauge
61-100 ft. 10 gauge
101-150 ft. 8 gauge
151-250 ft. 6 gauge
Figure 2.7 Output Connector Wiring for Stereo
with Optional CEAS1 Output Module.
2 Setup
Figure 2.6 Neutrik
®
Speakon
®
Connector
Figure 2.8 Optional CEAS2 5-way Binding Post Output Connector (Left)
Each Pair of Posts Connects to a Dual Banana Plug (Right)
page 9
CE Series Power Amplifiers
Operation Manual
2.6 Wire Your System
2.6.1 Stereo Mode
Make sure the amplifier is turned off and the
level controls are turned down before you wire
the system.
Typical input and output wiring is shown in
Figure 2.9.
INPUTS: Connect input wiring for each channel.
OUTPUTS: Maintain proper polarity (+/–) on
output connectors.
Connect Channel-1 positive (+) speaker load to
Channel-1 positive terminal of amp; repeat for
negative (–). Repeat each channel wiring as for
Channel 1. Refer to Section 3.5 for output con-
nector pin assignments. Make sure the Mode
switch is set to the “Stereo” position when oper-
ating in Stereo mode.
2.6.2 How to Parallel the Inputs
There are three ways to feed the same signal to
each amplifier channel:
1. Buy a "Y" cable. Plug the female end into your
signal cable, and plug the split male ends into
both amplifier inputs.
2. Feed your signal to the Channel-1 input
(either barrier-block or combo). Connect a
jumper wire (Figure 2.10) between the barrier-
block Channel-1 (+) screw terminal and the
Channel-2 (+) screw terminal. Connect another
jumper wire between the Channel-1 (–) screw
terminal and the Channel-2 (–) screw terminal.
3. Feed your signal to the Channel-1 input screw
terminals. Using a mic cable or phone-to-phone
cable, connect Channel-1 combo jack to Chan-
nel-2 combo jack.
See the next page for Bridge-Mono wiring.
2 Setup
Figure 2.9 Typical System Wiring, Stereo Mode
Figure 2.10
Jumper Placement
to Parallel the Inputs
Operation Manual
CE Series Power Amplifiers
page 10
2 Setup
Figure 2.11 Typical System Wiring, Bridge-Mono Mode
2.6.3 Bridge-Mono Mode
Make sure the amplifier is turned off and the
level controls are turned down before you wire
the system.
Typical input and output wiring is shown in
Figure 2.11.
INPUTS: Connect input wiring to CH 1.
OUTPUTS: Connect the speaker across the posi-
tive (+) output terminals. Do not use the negative
(–) terminals when the amplifier is being oper-
ated in Bridge-Mono mode. Refer to Section 2.5
for output connector pin assignments. Make
sure the Mode switch is set to the “Bridge” posi-
tion when operating in Bridge-Mono mode.
NOTE: Turn down (full CCW) the Channel
2 level control when operating the
channel pair in Bridge-Mono mode, as
the Channel 1 level control works both
channels.
NOTE: Crown provides a reference of wiring pin
assignments for commonly used connector
types in the Crown Amplifier Application Guide
available at www.crownaudio.com.
page 11
CE Series Power Amplifiers
Operation Manual
2.8 Connect to AC Mains
Connect your amplifier to the AC mains power
source (power outlet) with the supplied AC power
cordset. First, connect the IEC end of the cordset to
the IEC connector on the amplifier; then, plug the
other end of the cordset to the AC mains.
WARNING: The third prong of this connec-
tor (ground) is an important safety feature.
Do not attempt to disable this ground con-
nection by using an adapter or other meth-
ods.
Amplifiers don’t create energy. The AC mains volt-
age and current must be sufficient to deliver the
power you expect. You must operate your amplifier
from an AC mains power source with not more than
10% variation above or below the amplifier’s speci-
fied line voltage and within the specfied frequency
requirements (indicated on the amplifier’s back
panel label). If you are unsure of the output voltage
of your AC mains, please consult your electrician.
2.9 Startup Procedure
Use the following procedure when first turning on
your amplifier:
1. Turn down the level of your audio source.
2. Turn down the level controls of the amplifier.
3. Turn on the “Power” switch. The Power indicator-
should glow.
4. Turn up the level of your audio source to an opti-
mum level.
5. Turn up the Level controls on the amplifier until
the desired loudness or power level is achieved.
6. Turn down the level of your audio source to its
normal range.
If you ever need to make any wiring or installation
changes, don’t forget to disconnect the power cord.
For help with determining your system’s optimum
gain structure (signal levels) please refer to the
Crown Amplifier Application Guide, available online
at www.crownaudio.com.
2.7 Input Sensitivity Switch
A two-position Input Sensitivity switch is located
on the back panel near the input connectors
(Figure 2.12). Your amplifier is shipped from the
factory with this switch set to the 1.4V position.
At this setting, a 1.4V input signal will drive the
amplifier to full power into an 8-ohm load when
the level controls are turned to maximum. This
setting works best when the amplifier is being
driven by equipment with a +4 dBu output — an
output level at which most professional equip-
ment operates.
If required, the Input Sensitivity switch can be
moved to the 26-dB position, so that the ampli-
fier provides a fixed voltage gain of 20 (or 26 dB:
1 volt in, 20 volts out). This setting works best
with output levels of +10 dBu (2.5 volts RMS) or
more. Some brands of DJ mixers, in particular,
have output levels in this range.
Selecting the correct sensitivity will allow your
equipment to operate at its optimum level and
improve the signal-to-noise of the system.
Make sure the amplifier is turned off and
the level controls are turned down before
you change the switch setting.
Figure 2.12 Location of Input Sensitivity Switch
2 Setup
Sensitivity Switch
Operation Manual
CE Series Power Amplifiers
page 12
3.1 Precautions
Your amplifier is protected from internal and exter-
nal faults, but you should still take the following
precautions for optimum performance and safety:
1. Before use, your amplifier first must be config-
ured for proper operation, including input and
output wiring hookup. Improper wiring can
result in serious operating difficulties. For
information on wiring and configuration, please
consult the Setup section of this manual or, for
advanced setup techniques, consult Crown’s
Amplifier Application Guide available online at
www.crownaudio.com.
2. Use care when making connections, selecting
signal sources and controlling the output level.
The load you save may be your own!
3. Do not short the ground lead of an output cable
to the input signal ground. This may form a
ground loop and cause oscillations.
3 Operation
4. WARNING: Never connect the output to
a power supply, battery or power main.
Electrical shock may result.
5. Tampering with the circuitry, or making unau-
thorized circuit changes may be hazardous and
invalidates all agency listings.
6. Do not operate the amplifier with the red Clip
LEDs constantly flashing.
7. Do not overdrive the mixer, which will cause
clipped signal to be sent to the amplifier. Such
signals will be reproduced with extreme accu-
racy, and loudspeaker damage may result.
8. Do not operate the amplifier with less than the
rated load impedance. Due to the amplifier’s
output protection, such a configuration may
result in premature clipping and speaker dam-
age.
Remember: Crown is not liable for damage that
results from overdriving other system components.
page 13
CE Series Power Amplifiers
Operation Manual
Figure 3.1
Controls,
Indicators &
Connectors
3 Operation
3.2 Controls, Indicators and Connectors
Operation Manual
CE Series Power Amplifiers
page 14
3 Operation
3.4 Back Panel Controls and
Connectors
Input Sensitivity Switch
This two-position Input Sensitivity switch is located
near the input connectors. It lets you select between
1.4 V input sensitivity or 26 dB gain. Please see
Section 2.7 in this manual for details.
Mode Switch
This two-position switch selects either Stereo or
Bridge-Mono mode of operation. Stereo mode pro-
vides identical power output to each of the two
amplifier output channels. Bridge-Mono mode
combines the two amplifier output channels into a
single mono channel with twice the voltage of a sin-
gle stereo channel.
Do NOT select Bridge-Mono mode without
first making sure the amplifier has been
wired in a Bridge-Mono configuration. For
more information on wiring for Bridge-Mono mode,
see Section 2.6.2.
Fault Jack
This is an RJ-11 jack (which looks like a telephone
jack). By attaching a signaling device to the Fault
jack, you can monitor the amplifier’s Fault status
from a remote location. See Section 4.2.2 for more
information on fault monitoring.
Barrier Block Inputs
For each channel, this row of screw terminals pro-
vides a balanced input, which is in parallel with the
channel’s Combo input connector.
Neutrik Combo Input
One per channel, this combination 1/4-inch phone
jack and XLR connector provides a balanced or
unbalanced input.
Neutrik Speakon
®
Output
One per channel, this Neutrik Speakon
®
connector
with four terminals connects to loudspeakers.
See Section 4.2.2 in this manual for more informa-
tion on fault monitoring and suggestions for signal-
ling device circuity.
Some fault conditions may cause the output of the
amplifier to be muted.
Clip Indicators
These are two red LEDs (one per channel). The Clip
Indicator turns on when distortion is audible in the
amplifier output.
Signal Indicators
These are two green LEDs (one per channel). The
Signal Indicator illuminates when a signal (> –40
dBm) is present at the INPUT of the amplifier for
that channel. Because these indicators receive the
signal before the level controls, they can be used to
troubleshoot wiring problems within a system. If the
Signal indicator for a channel is not lit, no signal is
reaching the amplifier on that channel.
Power Indicator
The green Power indicator lights when your CE-
Series amp has been turned on and has power.
Level Controls
Two rotary detented Level controls (one for each
channel) are are used to adjust each channel’s out-
put.
If you wish, the level control knobs may be pulled
from the front panel and the holes plugged with the
supplied caps to minimize tampering of control set-
tings.
3.3 Front Panel Controls and
Indicators
Power Switch
The power switch turns the amplifier on (“I”) or off
(“O”).
Note that dangerous voltages may still be
present in the amplifier even when the
power switch is in the off (“O”) position.
Before moving the amplifier or making any wiring or
installation changes, it is important to also discon-
nect the power cord from the amplifier or power
source.
Reset Switch
The push-button reset switch is used to reset the
circuit breaker that protects the power supply.
Fault Indicators
Two red LEDs (one for each channel) are located on
the front panel. The Fault Indicators are normally
OFF, but will blink under five different conditions:
1. When the amplifier is first powered up, until the
unit is ready for operation.
2. If the heatsinks reach a temperature above normal
working limits.
3. If the transformer thermal protection circuit is
activated.
4. If the amplifier output wires develop a short-cir-
cuit.
5. If the amplifier output stage stops operating.
The fault status of the amplifier can also be moni-
tored remotely by attaching a signalling device to
the Fault jack located on the amplifier back panel.
page 15
CE Series Power Amplifiers
Operation Manual
NOTE: For detailed information about
these Crown amplifier features, please
consult the Crown Amplifier Application
Guide, available on the Crown website
at www.crownaudio.com.
4.1 Protection Systems
CE Series amplifiers are protected against
shorted, open or mismatched loads; over-
loaded power supplies; excessive temperature;
chain destruction phenomena; input overload
damage; and high-frequency blowups. They
also protect loudspeakers from input/output
DC, large or dangerous DC offsets and turn-on/
turn-off transients.
4.1.1 Bias Servo
Bias servo translates the output heatsink tem-
perature to controlled bias current. This pre-
vents thermal runaway and holds the amplifier’s
notch distortion to a minimum.
4.1.2 Fault
The amplifier will light the Fault LED on the
front panel if the amplifier output stage stops
operating. If this happens, take the unit to an
authorized Crown Service Center.
4.1.3 Ultrasonic and Radio Fre-
quency Protection
An amplifier's slew rate only needs to be large
enough to deliver the maximum voltage at the
highest required frequency. Higher slew rates
actually let the amplifier reproduce undesirable
frequencies. By design, the CE Series amplifi-
ers have a controlled slew rate to put a fre-
quency limit on the highest frequencies that
they reproduce. This limit occurs well above 20
kHz, so there is no audible effect on perfor-
mance.
This approach protects the amplifier from radio
frequencies and can even protect some sensi-
tive loads (including some tweeters).
4.1.4 Drive Protection
This system temporarily removes output drive
to protect the amplifier and its loads. Drive pro-
tection can be activated in two situations. First,
if dangerous subsonic frequencies or direct
current (DC) is detected in the amplifier's out-
put, drive protection will activate. The amplifier
resumes normal operation when it no longer
detects dangerous output. Activating this pro-
tection is very unlikely, but improper source
signals like infrasonic square waves or a
severely clipped input signal can activate this
system.
Second, the amplifier's fault protection system
puts the affected channel into drive protection
mode in rare situations where heavy common-
mode current is detected in its output. The
amplifier should never output heavy common-
mode current unless its circuitry is damaged.
Activating drive protection helps prevent further
damage.
4.1.5 Compression
A full-time compressor is in-line with the sig-
nal, reducing the risk of damage to your speak-
ers.
4.1.6 Power Circuit Breaker
A front panel push button is used to reset the
circuit breaker that protects the power supply.
4.1.7 Proportional-speed Fan
The speed of the cooling fan is controlled by
the transformer temperature and the heatsink
temperature.
4.2 Advanced Features
4.2.1 Crown SST Modules
Crown optional SST (System Solution Topolo-
gies) modules were specially designed to
improve the fidelity and versatility of your audio
system. They feature a variety of professional
signal routing and filtering capabilities, with
active crossovers that allow the audio signal to
be split and sent to auxiliary amplifiers. Your
amplifier may have come with an SST module
already factory-installed, or your choice of SST
modules can be easily added to the amplifier by
any authorized Crown Service Center.
For information on wiring and configuration of
amplifiers equipped with an optional Crown
SST crossover module, please refer to the SST
Crossover Reference Manual included in your
literature package.
Refer to the following descriptions for an over-
view of available Crown SST crossover mod-
ules. Crown plans to release additional
accessory plug-in modules offering a range of
advanced features and capabilities. Watch for
new releases:
SST-MX Crossover
Features include:
Stereo biamp.
100-Hz fixed crossover with 24-dB/octave
Linkwitz-Riley tuned filters.
•Neutrik
®
Combo 1/4-inch (6.35-mm) and
XLR input jacks.
Barrier block balanced outputs.
Optional high-pass filter bypass on ampli-
fied outputs adapts system for full-range
use.
SST-SX Crossover
Features include:
Mono-summed sub-bass output for biamp
operation of subs.
24-dB/octave Linkwitz-Riley tuned filters.
Crossover switchable between 80 and 120
Hz.
•Neutrik
®
Combo 1/4-inch (6.35-mm) and
XLR input jacks.
Male 3-pin XLR outputs.
Optional high-pass filter bypass on amplified
output adapts system for full-range use.
4 Advanced Features
and Options
Operation Manual
CE Series Power Amplifiers
page 16
SST-SBSC (Summed Bass Stereo
Crossover) Module
See Figure 4.1. Features include:
Stereo biamp.
Ten user-specified crossover frequencies.
12-, 18- and 24-dB/octave
(Linkwitz-Riley) filters.
CD horn equalization.
Mono summing of sub-bass output for
driving subs.
SST-SBSC-3632T
This is a custom three-channel crossover net-
work with CD-horn equalization and summed
low-frequency output specifically designed for
use with JBL
®
model 3632T ScreenArray
®
cinema speaker systems installed in cinemas,
studio production and post-production envi-
ronments.
Features:
High-frequency signals are internally
routed to the channel-one amplifier input,
and mid-frequency signals are routed to
the channel-two amplifier input.
Mono summing of low-frequency signals
are routed from Output B to an external
amplifier.
•Neutrik
®
Combo jacks for balanced input
connection.
Removable barrier block connectors for
balanced output to other components.
SST-SBSC 4632T
Like the SST-SBSC 3632T but for the JBL
4632T cinema speakers.
SST-4622
See Figure 4.2. This is a custom two-channel
crossover network with equalization specifically
designed for use with JBL
®
model 4622
ScreenArray
®
cinema speaker systems
installed in cinemas, studio production and
post-production environments.
Features include:
Low-frequency signals are internally
routed to the channel-1 amplifier input,
and high-frequency signals are routed to
the channel-2 amplifier input.
Barrier block connectors for balanced sig-
nal input.
SST-3632
Like the SST-4622 but for the JBL 3632 cinema
speaker systems.
Additional features include:
Time correction via an all-pass analog
delay ensures coherent summation
through the crossover region, while main-
taining optimal vertical polar response.
SST-4632
Like the SST-3632 but for the JBL 4632 cinema
speaker systems.
Figure 4.1 SST-SBSC
Crossover Network
Figure 4.2 SST-4622
Crossover Network
4 Advanced Features
and Options
page 17
CE Series Power Amplifiers
Operation Manual
4.2.2 Fault Monitoring
The Fault (RJ-11) jack, which looks like a telephone
jack, is located on the back of your CE Series ampli-
fier (Figure 4.3). It gives you an easy way to
remotely monitor the amplifier’s fault status. To set
up a circuit that will cause an LED to light whenever
a fault status occurs, you can simply use the sug-
gested circuit shown in Figure 4.4.
When using this circuit, the LED will glow under
any of these conditions:
• The amplifier has just been turned on and is still
in the 4-second turn-on delay.
• The heatsinks are too hot.
•The transformer thermal protection is activated.
• The amplifier output wires have developed a short
circuit.
• The limiter has been overdriven by > 6 dB for a
long time.
• The amplifier output stage has stopped operating.
Refer the unit to an authorized Crown Service Cen-
ter.
• The amplifier is turned off.
If you choose to design your own circuit to interface
this signal to your system, note that this RJ jack is
polarity sensitive. Pin 2 must be grounded, and Pin
5 must be supplied with a positive voltage pull-up
(positive with respect to ground). Refer to Figure 4.5
for RJ jack pin assignments. The maximum signal
that can be exposed to the Fault jack is 35VDC and
10 mA. Best results are obtained with 10 mA LEDs.
The mating connector for the CE Series TX RJ-11
jack contains 4 contact pins in a 6-slot case, as
shown. For additional information please contact
your local dealer or Crown Technical Support.
Figure 4.4 Fault Status LED Circuitry
Figure 4.5 RJ-11 Jack Wiring and Pin Assignments
4 Advanced Features
and Options
Figure 4.3 Location of Fault Jack
Operation Manual
CE Series Power Amplifiers
page 18
4.3.3 Tamper-Resistant Hole Plugs
Your CE Series amplifier comes with a set of
tamper-resistant hole plugs, which allow you to
“protect” the level controls against unauthorized
adjustment. To use, simply pull off the control
knobs from the front of the amp, and slip the hole
plugs into place (see Figure 4.8). The plugs should
press easily into position with light force. Once in
place, the plugs will help to avoid most accidental
or intentional tampering (some situations may
require additional security measures).
To remove the hole plugs, simply pry the plug away
from the amplifier case using a small, flat-blade
screwdriver. To help to ensure adequate security, the
plugs have been designed to be more difficult to
remove than to place into position. If necessary,
additional hole plugs can be purchased separately
from Crown’s Parts Department (Part # 103234-1).
Store your knobs in a safe location should you need
to make level adjustments in the future.
4.3.4 Optional 0.775 V Input
Sensitivity Setting
The CE Series amplifier also provides an optional
0.775 V input sensitivity setting. If you determine
that your application requires this sensitivity set-
ting, please contact Crown Technical Support for
more information.
4 Advanced Features
and Options
Figure 4.6 Model CEAS1 Barrier Block
Output Connectors
Figure 4.7 Model CEAS2 5-way
Binding Post Output Connectors
Figure 4.8 Tamper-Resistant Hole Plugs
Installed in a CE Series Amplifier
4.3 Options
4.3.1 Accessories
CE HANDLES
Handles complement your amplifier’s appearance,
aid in transportation, and facilitate rack mounting
and removal. They are available from Crown’s Sales
Department; just ask for “CE Handles.”
CE-S1
Speakon to barrier output adapter. Compatible with
CE versions CE 1000 and CE 2000 amplifiers (ini-
tial release).
CE-S2
Speakon to 5-way binding post adapter.Compatible
with CE versions CE 1000 and CE 2000 amplifiers
(initial release).
4.3.2 Alternate Output Connectors
For added system flexibility, Crown offers optional
secondary output connectors that are compatible
with the current CE versions: CE 1000A , CE 2000A,
CE 1000B and CE 2000B amplifiers. (These model
numbers are printed only on the serial number
label.)
You have a choice of either the CEAS1 barrier block
(see Figure 4.6) or the CEAS2 5-way binding post
connectors (see Figure 4.7). Alternate output con-
nectors may come factory installed on new amplifier
orders. They can also be added to existing CE
Series amplifiers by an authorized Crown Service
Center. For more information, please contact Crown
Technical Support.
page 19
CE Series Power Amplifiers
Operation Manual
For the sake of simplicity, only channel one of
the amplifier is described.
Signal is presented to the CE amplifier through
one of three connectors when using the stan-
dard input module. Each channel is outfitted
with a balanced XLR/phone jack and a barrier
strip. These connectors are wired in parallel,
which allows daisy chaining when needed. The
signal is then converted from balanced to
unbalanced in the Balanced Input Stage where
it also receives RFI protection. Signal then
flows into the Variable Gain Stage where the
front panel level controls are allowed to affect
the gain.
Following this stage, the signal is put under the
control of a full-time compressor circuit com-
prised of a symmetrical window detector, a
buffer amplifier, and the gating op amp which
uses several small components to set the com-
pressor’s attack and decay characteristics. The
actual compressing is accomplished by an
opto-isolator which affects the gain in the sig-
nal path.
Next the signal enters the error amplifier circuit,
where it is mixed with a small portion of the
output signal in such a way as to control the
amplifier’s overall output perfomance.
Following the error amp is the LVA stage, which
is where the low-voltage referenced signal gets
translated to the output high-voltage rails. The
last voltage amplifier, in conjunction with a
bootstrap current source, drives both predriv-
ers and the bias servo. The bias servo is
mounted in such a way as to translate the out-
put heatsink temperature into a controlled bias
current to prevent thermal runaway and hold
the amplifier’s notch distortion to a minimum.
The predrivers provide enough signal to acti-
vate the drivers, which together operate in the
class AB range. For the major output current
requirements, the drivers feed the various num-
bers of paralleled output transistors which
operate in a class B mode. This we call the Tri-
ple-Deep Darlington Output Stages.
The output transistors are protected by the Time
Dependent Voltage & Current circuit. This cir-
cuit protects the devices from extending
beyond their safe area of operation, but allows
the devices to provide high bursts of peak
power with music, allowing your amplifier to
deliver more punch. This amplifier output
topology offers a good combination of low qui-
escent amplifier heating, great distortion per-
formance at high powers, and relative
simplicity, with impressive reliability and value.
All output power is delivered through 4-circuit
Speakon
®
connectors. These connectors have
been wired in such a way as to allow you the
most versatility. The Channel 1 and 2 connec-
tors are cross wired so you can cover all
options, from dual cable stereo (typical), to
Bridge-Mono in one connector, to running a bi-
amp speaker with one amplifier and one cable
per speaker cabinet.
The output relay, in conjunction with input sig-
nal mute circuit, assures the amplifier will be
well-behaved during turn on and off. In the
event of an amplifier output failure, a triac will
activate to turn off the offending channel and
protect your speakers.
The turn on delay circuit functions to keep the
output relay open until all the voltages are up
and stable, both in the amplifier, and in all the
components in the system ahead of the
amplifier.
Heatsink temperature is monitored by a thermal
probe attached to the heatsink. As the tempera-
ture rises, the probe sends a proportional cur-
rent to the proportional speed fan circuit which
starts the fan. Should the power transformer
reach its maximum safe temperature, an inter-
nal thermal switch opens and the fan circuit
turns on full speed to quickly cool down the
amplifier. It also disconnects the load via the
output relay, removing any output current and
further speeding a cool-down cycle. Extra care
was taken during the design stage to set this
point both to protect your investment and to
guard against nuisance tripping.
Whenever the heatsinks or the transformer
reach a maximum temperature, or during the
normal turn-on delay window, the front panel
Fault LEDs will blink to get your attention.
A modular jack is mounted on the back panel
(same type as used on telephones). Pins 2 and
5 are connected to an opto-isolator which is
always in a low-resistance state whenever the
unit is on and functional. Should a fault be
detected or should the amplifier lose AC power,
the opto-isolator will change to a high resis-
tance, allowing the user to remotely detect the
status of the amplifier.
The Signal Presence Indicators tap the signal
chain just before the level controls and prior to
the power amplifier chain. They are not ampli-
fier output indicators and should only be used
to indicate the presence of signal to the ampli-
fier front end.
The Clip light is driven from the output of the
compressor circuitry and lights to indicate the
onset of audible distortion.
The Power LED is driven from the low-voltage
supply.
A positive and negative regulator form the ±15-
volt power supplies. Add to that the main trans-
former, a full-wave bridge rectifier, and high
energy electrolytic to form the main power sup-
ply. They are protected by the front-panel line
circuit breaker and controlled by the front-panel
power switch.
5 Principles of Operation
Operation Manual
CE Series Power Amplifiers
page 20
5 Principles of Operation
Figure 5.1
CE Series
Amplifier Block
Diagram
(Shown with
Standard Input
Module)
TRANSLATOR LVA
BIAS
CURRENT
SOURCE
BALANCE
INPUT STAGE
VARIABLE
GAIN STAGE
ERROR
AMP
BALANCED
INPUTS
TO SIGNAL
PRESENCE
INDICATOR
COMPRESSOR
CONTROL
TO CLIP
INDICATOR
BUFFER
MUTE
DC PROTECT
LOGIC
TO
FAULT
CONNECTOR
–VCC
–VCC
+ HI-VOLTAGE
BOOTSTRAP
BIASBIASBIASBIASBIAS
TDVI
LIMITER
TRIPLE-DEEP
DARLINGTON
NPN POSITIVE
OUTPUT STAGE
TRIPLE-DEEP
DARLINGTON
NPN NEGATIVE
OUTPUT STAGE
PROPORTIONAL
SPEED
FAN
CONTROL
FAN
DC
PROTECT
HEATSINK
TEMPERATURE
OUTPUT
CONTROL
HEATSINK
TEMPERATURE
TRANSFORMER
TEMPERATURE
TO FAULT
INDICATOR
POWER
SUPPLY
+ VCC
+ 15V
– 15V
– VCC
TURN-ON
DELAY
+
OUTPUT
BOOTSTRAP
CIRCUIT
+ HI-VOLTAGE
BOOTSTRAP
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Crown Audio CE SERIES User manual

Category
Supplementary music equipment
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI