Emerson RP4AF User manual

Type
User manual

Emerson RP4AF, a reliable electric actuator, offers enhanced control with its 4x relay outputs. Easily programmable using SMARTTOOL2 software, it allows customization of relay functionality. Ideal for industrial applications requiring precise positioning and remote monitoring.

Emerson RP4AF, a reliable electric actuator, offers enhanced control with its 4x relay outputs. Easily programmable using SMARTTOOL2 software, it allows customization of relay functionality. Ideal for industrial applications requiring precise positioning and remote monitoring.

Bettis RTS Relay Board (RP4AF)
Electric Actuator
Installation, Operation and Maintenance Manual
VCIOM-15749-EN Rev. 0
June 2021
Revision Details
June 2021
Installation, Operation and Maintenance Manual
VCIOM-15749-EN Rev. 0
Revision Details
No. Date Version Type of Change
1 June 2021 0 General update
(Migration to new template)
Revision Details
i
Table of Contents
June 2021
Installation, Operation and Maintenance Manual
VCIOM-15749-EN Rev. 0
Table of Contents
Table of Contents
Section 1: Tools
Tools.........................................................................................................................1
Section 2: Material
Material.....................................................................................................................2
Section 3: Installation
Installation................................................................................................................3
Section 4: Programming
Programming............................................................................................................7
Notes
June 2021
Installation, Operation and Maintenance Manual
VCIOM-15749-EN Rev. 0
This page is intentionally left blank
June 2021
Installation, Operation and Maintenance Manual
VCIOM-15749-EN Rev. 0
1Tools
Section 1: Tools
1
Section 1: Tools
! WARNING
Remove all power supplies before doing the exchange. Act always with caution during
the exchange!
Needle nose pliers
Screw driver phillips
Screw driver at
Allen key 5
Socket wrench 5
Figure 1
June 2021
Installation, Operation and Maintenance Manual
VCIOM-15749-EN Rev. 0 Rev. 0
2Material
Section 2: Material
2
Section 2: Material
1x relay board RP4AF (ID:15772)
2x steel screw M3x16 (ID:952)
3x plastic distance 8 mm (ID:9896)
1x plastic screw M3x15 (ID:9895)
1x plastic nut M3 (ID:7084)
2x lock plates M3 red (ID:13674)
Figure 2
Figure 3
June 2021
Installation, Operation and Maintenance Manual
VCIOM-15749-EN Rev. 0
3Installation
Section 3: Installation
3
Section 3: Installation
Unscrew the 4 hexagon socket screws from the cover and remove it carefully. Mind the
connection cable between display and logic board.
Figure 4
Unscrew the 4 cross recessed screws from the existing logic board and afterwards tilt it
carefully to you.
Figure 5
June 2021
Installation, Operation and Maintenance Manual
VCIOM-15749-EN Rev. 0 Rev. 0
4Installation
Section 3: Installation
4
Remove the cable with the 10-pole connector and connect it with the relay board.
Figure 6
Insert plastic screw M3x15 in provided hole and add plastic distance on it, after connect the
relay board with the logic board on suitable connector. Add plastic nut on plastic screw to
x the board.
Figure 7
June 2021
Installation, Operation and Maintenance Manual
VCIOM-15749-EN Rev. 0
5Installation
Section 3: Installation
5
Put two plastic distances 8 mm between logic and relay board, insert the M3x16 steel
screws through the estimated holes in logic board, plastic distances and relay board and
secure the screws with the red lock plates.
Figure 8
Install die logic + relay board back to the control (two small screws for original installation
will remain). Take care of possible damage of cables or other parts.
Figure 9
June 2021
Installation, Operation and Maintenance Manual
VCIOM-15749-EN Rev. 0 Rev. 0
6Installation
Section 3: Installation
6
Connect cable between display cover and logic board. Perform a Firmware update now,
before installing display cover on the unit. This update is important for the following
programming steps (use FW version display 1507, logic 219 or higher). For a detailed
description on how to perform a rmware update, please refer to separate manual.
During display cover installation, pay attention to the O-ring which must be sit correct
between cover and housing and x it with the 4 hexagon socket screws.
Figure 10
June 2021
Installation, Operation and Maintenance Manual
VCIOM-15749-EN Rev. 0
7Programming
Section 4: Programming
7
Section 4: Programming
For programming, request download of SMARTTOOL2 through your Sales Representative.
After the successful installation and registration, connect with the actuator. Use the Wizard
and choose function "Install Extension Kit" and press "Apply".
Figure 11
At the line "RP4AF: 4x Relay Outputs" press "Apply" and conrm the installation by
pressing "Ja".
Figure 12
June 2021
Installation, Operation and Maintenance Manual
VCIOM-15749-EN Rev. 0 Rev. 0
8Programming
Section 4: Programming
After installation press the "Refresh Button". In parameter group "10. Relay" you can dene
the functionality of the different relay’s.
Figure 13
8
Installation, Operation and Maintenance Manual
VCIOM-15749-EN Rev. 0
Notes
June 2021
This page is intentionally left blank
World Area Conguration Centers (WACC) offer sales support, service,
inventory and commissioning to our global customers.
Choose the WACC or sales ofce nearest you:
www.emerson.com/bettis
VCIOM-15749-EN ©2021 Emerson. All rights reserved.
The Emerson logo is a trademark and service mark of Emerson Electric Co.
BettisTM is a mark of one of the Emerson family of companies.
All other marks are property of their respective owners.
The contents of this publication are presented for information purposes
only, and while effort has been made to ensure their accuracy, they are not
to be construed as warranties or guarantees, express or implied, regarding
the products or services described herein or their use or applicability.
All sales are governed by our terms and conditions, which are available
on request. We reserve the right to modify or improve the designs or
specifications of our products at any time without notice.
For complete list of sales and manufacturing sites, please visit
www.emerson.com/actuationtechnologieslocations or contact us at
info.actuationtechnologies@emerson.com
NORTH & SOUTH AMERICA
19200 Northwest Freeway
Houston TX 77065
USA
T +1 281 477 4100
Av. Hollingsworth
325 Iporanga Sorocaba
SP 18087-105
Brazil
T +55 15 3413 8888
ASIA PACIFIC
No. 9 Gul Road
#01-02 Singapore 629361
T +65 6777 8211
No. 1 Lai Yuan Road
Wuqing Development Area
Tianjin 301700
P. R. China
T +86 22 8212 3300
MIDDLE EAST & AFRICA
P. O. Box 17033
Jebel Ali Free Zone
Dubai
T +971 4 811 8100
P. O. Box 10305
Jubail 31961
Saudi Arabia
T +966 3 340 8650
24 Angus Crescent
Longmeadow Business Estate East
P.O. Box 6908 Greenstone
1616 Modderfontein Extension 5
South Africa
T +27 11 451 3700
EUROPE
Holland Fasor 6
Székesfehérvár 8000
Hungary
T +36 22 53 09 50
Strada Biffi 165
29017 Fiorenzuola d’Arda (PC)
Italy
T +39 0523 944 411
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

Emerson RP4AF User manual

Type
User manual

Emerson RP4AF, a reliable electric actuator, offers enhanced control with its 4x relay outputs. Easily programmable using SMARTTOOL2 software, it allows customization of relay functionality. Ideal for industrial applications requiring precise positioning and remote monitoring.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI