Emerson RP3E User manual

Type
User manual

Emerson RP3E is a relay board designed for use with electric actuators. It features 6 relay outputs and 3 inputs, allowing for a variety of control options. The RP3E is easy to install and program, making it a versatile solution for a wide range of applications. It can be used to control lighting, motors, pumps, and other electrical devices. With its compact size and DIN rail mounting, the RP3E is a space-saving solution for control panels.

Emerson RP3E is a relay board designed for use with electric actuators. It features 6 relay outputs and 3 inputs, allowing for a variety of control options. The RP3E is easy to install and program, making it a versatile solution for a wide range of applications. It can be used to control lighting, motors, pumps, and other electrical devices. With its compact size and DIN rail mounting, the RP3E is a space-saving solution for control panels.

Bettis RTS Relay Board (RP3E)
Electric Actuator
Installation, Operation and Maintenance Manual
VCIOM-15746-EN Rev. 0
June 2021
Revision Details
June 2021
Installation, Operation and Maintenance Manual
VCIOM-15746-EN Rev. 0
Revision Details
Revision Details
No. Date Version Type of Change
1 June 2021 0 General update
(Migration to new template)
i
Installation, Operation and Maintenance Manual
VCIOM-15746-EN Rev. 0
Table of Contents
June 2021
Table of Contents
Table of Contents
Section 1: Tools
Tools.........................................................................................................................1
Section 2: Material
Material.....................................................................................................................2
Section 3: Installation
Installation................................................................................................................3
Section 4: Programming
Programming............................................................................................................8
Notes
June 2021
Installation, Operation and Maintenance Manual
VCIOM-15746-EN Rev. 0
This page is intentionally left blank
Installation, Operation and Maintenance Manual
VCIOM-15746-EN Rev. 0 June 2021
Tools 1
Section 1: Tools
Section 1: Tools
! WARNING
Remove all power supplies before doing the exchange. Act always with caution during
the exchange!
Needle nose pliers
Screw driver phillips
Screw driver at
Allen key 5
Socket wrench 5
Figure 1
June 2021
Installation, Operation and Maintenance Manual
VCIOM-15746-EN Rev. 0
Material
2
Section 2: Material
Section 2: Material
1x relay board RP3E6A (ID:13009)
1x adapter cable (ID:16504)
2x steel screw M3x16 (ID:952)
3x plastic distance 8 mm (ID:9896)
1x plastic screw M3x15 (ID:9895)
1x plastic nut M3 (ID:7084)
2x lock plates M3 red (ID:13674)
Figure 2
Figure 3
Installation, Operation and Maintenance Manual
VCIOM-15746-EN Rev. 0 June 2021
Installation 3
Section 3: Installation
Section 3: Installation
Unscrew the 4 hexagon socket screws from the cover and remove it carefully. Mind the
connection cable between display and logic board.
Figure 4
Unscrew the 4 cross recessed screws from the existing logic board and afterwards tilt it
carefully to you.
Figure 5
June 2021
Installation, Operation and Maintenance Manual
VCIOM-15746-EN Rev. 0
Installation4
Section 3: Installation
Remove carefully the connected cables: ribbon cable, 6-8-10-poles plugs. Afterwards you
can remove the logic board from the control unit and disconnect the 2nd ribbon cable on
the back.
Figure 6
Remove the two, marked with the red arrows, steel distances in the housing.
Figure 7
Installation, Operation and Maintenance Manual
VCIOM-15746-EN Rev. 0 June 2021
Installation 5
Section 3: Installation
Put the plastic distances 8 mm between logic and relay board, insert the M3x16 steel
screws through the estimated holes next to multi pin connector in logic board, plastic
distances and relay board and secure the screws with the red lock plates. For the 3rd hole
use the plastic screw M3x15 and secure it with plastic nut.
Figure 8
Connect the relay board with the multi-pin connector from the logic board.
NOTE
4 pins must stay free see FIgure 9.
Orientation brings the mounting holes of both boards – they must be in line.
Figure 9
June 2021
Installation, Operation and Maintenance Manual
VCIOM-15746-EN Rev. 0
Installation6
Section 3: Installation
Connect the adapter cable with the 10 and 6-pole connector, after connect blue
connectors with related one on the relay board.
Figure 10
Installation, Operation and Maintenance Manual
VCIOM-15746-EN Rev. 0 June 2021
Installation 7
Section 3: Installation
Connect both ribbon cable and 8-pole connector with the logic board, after install the
logic + relay board back to the control (two small screws for original installation will
remain). Take care of possible damage of cables or other parts.
Figure 11
Connect cable between display cover and logic board. Perform a Firmware update before
installing display cover on the unit. This update is important for the following programming
steps (use FW version display 1507, logic 219 or higher). For a detailed description on how
to preform a rmware update, please refer to separate manual.
During display cover installation, pay attention to the O-ring which must sit correct
between cover and housing and x it with the 4 hexagon socket screws.
Figure 12
June 2021
Installation, Operation and Maintenance Manual
VCIOM-15746-EN Rev. 0
Programming8
Section 4: Programming
Section 4: Programming
For programming, request download of SMARTTOOL2 through your Sales Representative.
After the successful installation and registration, connect with the actuator. Use the Wizard
and choose function "Install Extension Kit" and press "Apply".
Figure 13
At the line "RP3E6A: 6x Relay Outputs, 3x Inputs" press "Apply" and conrm the installation
by pressing "Ja".
Figure 14
Installation, Operation and Maintenance Manual
VCIOM-15746-EN Rev. 0 June 2021
Programming 9
Section 4: Programming
After installation press the "Refresh Button". In parameter group "9. Bin. Input" and
"10. Relay" you can dene the functionality of the different relays.
Figure 15
World Area Conguration Centers (WACC) offer sales support, service,
inventory and commissioning to our global customers.
Choose the WACC or sales ofce nearest you:
www.emerson.com/bettis
VCIOM-15746-EN ©2021 Emerson. All rights reserved.
The Emerson logo is a trademark and service mark of Emerson Electric Co.
BettisTM is a mark of one of the Emerson family of companies.
All other marks are property of their respective owners.
The contents of this publication are presented for information purposes
only, and while effort has been made to ensure their accuracy, they are not
to be construed as warranties or guarantees, express or implied, regarding
the products or services described herein or their use or applicability.
All sales are governed by our terms and conditions, which are available
on request. We reserve the right to modify or improve the designs or
specifications of our products at any time without notice.
For complete list of sales and manufacturing sites, please visit
www.emerson.com/actuationtechnologieslocations or contact us at
info.actuationtechnologies@emerson.com
NORTH & SOUTH AMERICA
19200 Northwest Freeway
Houston TX 77065
USA
T +1 281 477 4100
Av. Hollingsworth
325 Iporanga Sorocaba
SP 18087-105
Brazil
T +55 15 3413 8888
ASIA PACIFIC
No. 9 Gul Road
#01-02 Singapore 629361
T +65 6777 8211
No. 1 Lai Yuan Road
Wuqing Development Area
Tianjin 301700
P. R. China
T +86 22 8212 3300
MIDDLE EAST & AFRICA
P. O. Box 17033
Jebel Ali Free Zone
Dubai
T +971 4 811 8100
P. O. Box 10305
Jubail 31961
Saudi Arabia
T +966 3 340 8650
24 Angus Crescent
Longmeadow Business Estate East
P.O. Box 6908 Greenstone
1616 Modderfontein Extension 5
South Africa
T +27 11 451 3700
EUROPE
Holland Fasor 6
Székesfehérvár 8000
Hungary
T +36 22 53 09 50
Strada Biffi 165
29017 Fiorenzuola d’Arda (PC)
Italy
T +39 0523 944 411
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

Emerson RP3E User manual

Type
User manual

Emerson RP3E is a relay board designed for use with electric actuators. It features 6 relay outputs and 3 inputs, allowing for a variety of control options. The RP3E is easy to install and program, making it a versatile solution for a wide range of applications. It can be used to control lighting, motors, pumps, and other electrical devices. With its compact size and DIN rail mounting, the RP3E is a space-saving solution for control panels.

Ask a question and I''ll find the answer in the document