Extender Plus Series • Setup Guide
NOTE: Installation and service must be performed by authorized personnel only. These
products must be used with UL approved, grounded electrical boxes.
Step 1
Configure EDID Minder at the display device. The Extender Plus models offer two ways of
conguring EDID:
• EDID Record — Enables the device to record EDID
directly from a display.
1. Turn the rotary switch (
A
) to position 0.
NOTE: The DIP switch positions have no
effect in this mode.
2. Apply power to the Extender by connecting the
12 VDC power supply. The green LED (
B
) lights when
power is available.
3. Connect the display device to the input of the
Extender using a VGA cable.
4. Power on the display device.
5. Press and release the recessed EDID store button (
C
). The LED ashes red while
storing the EDID, then it turns solid green when the EDID data has been stored. The
display can now be disconnected.
NOTE: If an external supply was used for recording, it can now be disconnected.
• Pre-programmed EDID — The Extender Plus models contain pre‑programmed EDIDs with
the most common display native resolutions for both 50 and 60 Hz.
1. See Table 1 on page 9 of the Extender Plus Series User Guide to see which resolution
corresponds to each rotary switch (
A
) position. Set the rotary switch to the native
resolution of the display.
2. Set the rst DIP switch (
D
) to the vertical refresh frequency of the display (default is
ON, 60Hz).
Step 2
Turn all of the equipment off and disconnect the power cords from the power source.
Step 3
Select the installation location and install the electrical wall box (see Installation
Instructions on page 2 of the Extender Plus Series User Guide for details on installing the wall
box and cables).
NOTE: The Extron Extender Plus AAP does not require a wall box if it is installed into an
Extron HSA 400 Series or HSA 800 Series surface access product.