Solid State Logic Sigma Delta Installation guide

Type
Installation guide
Sigma
Installation Guide
Installations-Handbuch
Guia de Instalación
Guide d’Installation
Guida di Installazione
インストール・ガイド
Sigma. This is SSL.
EN
DE
ES
FR
IT
JP
82BMSGX1A Sigma Install 4_Print Layout 09/07/2013 11:05 Page a
English
This booklet contains practical information for the safe installation of this apparatus.
For operational information please refer to the User Guide.
Deutsch
Dieses Handbuch enthält wichtige Informationen zur sicheren Installation des Geräts.
Informationen zur Bedienung können Sie im User Guide finden.
Español 
Este manual contiene información práctica para la instalación segura de este aparato.
Para información acerca de su operación consulte la guía del usuario.
Français 
Ce livret contient des informations pratiques pour une installation sécurisée de l’appareil.
Veuillez vous référer au Guide de l’Utilisateur pour les informations opérationnelles.
Italiano 
Questo manuale contiene tutte le informazioni pratiche per una sicura installazione del dispositivo.
Per informazioni sul funzionamento dell’unità consultare l’apposito Manuale d’uso.
日本語
このインストールガイドには、設置に関する注意や安全にご使用いただくための情報が記載されています。
操作方法の詳細については、別紙のユーザーガイドをご参照ください。
EN
DE
ES
FR
IT
JP
82BMSGX1A Sigma Install 4_Print Layout 09/07/2013 11:05 Page c
Document History
BMSGXA (July ) Initial release
82BMSGX1A Sigma Install 4_Print Layout 09/07/2013 11:05 Page d
EN
DE
ES
FR
IT
JP
Introduction
Congratulations on your purchase of this Solid State Logic Sigma unit. Please be assured that it will provide you with
many years of reliable service while delivering the pristine quality you expect from any Solid State Logic product.
Sigma is a stylishly designed U rack-mountable unit, providing a remote-controlled analogue summing engine made
possible by Ctrl SuperAnalogue technology. Sigma works by grabbing the automation streams from your DAW (over a
standard Ethernet cable) and using them to drive the analogue signal levels.
The unit front panel offers LED signal level and routing indications, customisable user buttons and a level control. It
also offers a sturdy power switch, headphone socket and an iJack input to easily connect an MP player.
IMPORTANT
In order for Sigma to integrate with your DAW, ipMIDI software must be installed on your DAW computer. In
addition, configuration of Sigma will require the use of a standard internet web browser (Chrome, Firefox,
Safari, Internet Explorer, etc.). Please go to the Sigma page on the Solid State Logic website to register your
unit, download the necessary software and download a copy of the full Sigma User Guide which will guide you
through setup.
The Solid State Logic home page is at:
www.solidstatelogic.com
From the Sigma page of our website you will also find links to the Frequently Asked Questions (FAQ) area for
any questions you might have or to contact our Technical Support staff.
82BMSGX1A Sigma Install 4_Print Layout 09/07/2013 11:05 Page 1
Safety and Installation Considerations
This page contains definitions, warnings, and practical information to ensure a safe working environment.
Please take time to read this page before installing or using this unit. Please do not dispose of these instructions.
General Safety
Read these instructions.
Keep these instructions.
Heed all warnings.
Follow all instructions.
Do not use this apparatus near water.
Do not expose this apparatus to rain or moisture.
Clean only with dry cloth.
Do not block any ventilation openings. Install in accordance with the
manufacturer’s instructions.
Do not install near any heat sources such as radiators, heat registers, stoves
or other apparatus (including amplifiers) that produce heat.
There are no user-adjustments, or user-servicable items, inside this apparatus.
Do not remove the covers of this apparatus; doing so will invalidate your
warranty.
Adjustments or alterations to this apparatus may affect the performance such
that safety and/or international compliance standards may no longer be met.
Installation Notes
When installing this apparatus, either fix it into a standard " rack or place
the apparatus on a secure level surface.
When this apparatus is rack mounted, fit all rack screws. Rack shelves are
recommended for this apparatus.
Allow a U gap above and below this apparatus for cooling.
Ensure that no strain is placed on the cables connecting to this apparatus.
Ensure also that such cables are not placed where they can be stepped on,
pulled or tripped over.
Power Safety
This apparatus is supplied with a universal power supply, approved and
certified for operation with this apparatus. There are no user-replaceable fuses.
Use only the Solid State Logic provided power supply. Use of any other power
supply is not covered by your warranty and may cause fire or explosion.
Any external power supply may become hot during normal operation of the unit.
Use care when handling the power supply.
Do not attempt to modify the power supply unit in any way.
Multiple power cords may be supplied with this unit – use only the power cord
appropriate to your local power wiring. Alternative power cords may be used if
rated .A or above and fitted with a -pin IEC connector.
An external over-current protection device is required to protect the wiring to
this apparatus. This protection device must be installed according to current
wiring regulations. In certain countries this function is supplied by use of a
fused plug.
If an extension power cable or adaptor is used, ensure that the total power
rating of the power cable and/or adaptor is not exceeded.
An external disconnect device is required for this apparatus. The appliance
coupler is a suitable disconnect device. The appliance coupler shall remain
readily operable.
The power socket used for this apparatus should be located nearby and be
easily accessible.
Unplug this apparatus during an electrical storm or when unused for long
periods of time.
All power cords must be disconnected to isolate this apparatus completely.
Caution
Do not operate this apparatus with the covers removed.
To reduce the risk of electric shock, do not perform any servicing other than
that contained in these Installation Instructions unless you are qualified to do
so. Refer all servicing to qualified service personnel and ensure that all power
cords are disconnected when servicing this apparatus.
82BMSGX1A Sigma Install 4_Print Layout 09/07/2013 11:05 Page 2
EN
DE
ES
FR
IT
JP
Un-pack
Your Sigma box should contain the following:
5A
Sigma
Installation Guide
Installations-Handbuch
Guia de Instalación
Guide d’Installation
Guida di Installazione
インストールガイド
Sigma. This is SSL.
EN
DE
ES
FR
IT
JP
m Ethernet cable
External Mains Adaptor
JP
(marked ‘PSE’)
oror
The Sigma Unit
Multiple power cords may be supplied.
Please dispose of unused cords safely.
or
US
(marked ‘UL’)
EU
Installation Guide
(this document)
Power Cord(s)
82BMSGX1A Sigma Install 4_Print Layout 09/07/2013 11:05 Page 3
Front Panel
Sigma provides you with  stereo line inputs and  stereo line outputs on Tascam standard (AES) -pin D-sub
connectors. Using the web browser interface, the left input of each stereo channel can be selected as a mono source.
When an input is set to mono, the channel number on the front panel will glow green. Please note that setting an input
to mono does not give you 2 independent mono inputs!
Sigma also provides access to Mix Insert Send/Returns, a Line Level output for sending headphone feeds into a live
room, an external input and talkback input, all on standard DB- connections. Access to the Main Speaker Outputs,
Alternative Speaker Outputs and the Mix A Output is provided on XLR male connectors.
Power Switch
Customisable
User Buttons
Level Control
Master
Meter
iJack
Input
Headphones
Channel Numbers
Mix Bus A/B Indicators
Input Level Meters
Levels can be set for +18dBu, +22dBu or +24dBu via the web browser interface
82BMSGX1A Sigma Install 4_Print Layout 09/07/2013 11:05 Page 4
EN
DE
ES
FR
IT
JP
Connections
The FOOTSWITCH input is suitable for any standard on/off foot switch by default this turns Talkback On/Off
although this can be changed.
Use only the provided power supply – the clip above the power inlet should be used to retain the power lead and
so prevent accidental removal or damage.
Use a standard Ethernet cable (as supplied) to connect Sigma to your computer/network router.
The USB socket and PROG switch are for SSL diagnostic use and should not be connected or used.
Please refer to page  onward for connector pinouts.
Alternate
Monitor Output
Main Monitor
Output Mix A Output
Footswitch
Input
Clip to secure
power cable
Factory use only
Power Inlet
+V DC
Miscellaneous
Sends and Outputs
Miscellaneous
Returns and Inputs
 Stereo Channel Outputs
 Stereo Channel Inputs
Ethernet
82BMSGX1A Sigma Install 4_Print Layout 09/07/2013 11:05 Page 5
FCC Notice
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part  of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is used in a commercial environment. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation
of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Instructions for Disposal of WEEE by Users in the European Union
The symbol shown here is on the product or on its packaging, which indicates that this product must not be disposed of with other waste. Instead, it is the
user’s responsibility to dispose of their waste equipment by handing it over to a designated collection point for recycling of waste electrical and electronic
equipment. The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that
it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for
recycling, please contact your local city office, your household waste disposal service or where you purchased the product.
Standards Conformance
This apparatus fully conforms with the current protection requirements of the European community council directives on EMC and LVD.
Limited Warranty
Warranty claims will only be accepted if the purchased product has been used for its intended purpose. Any purchased product used for an
unintended purpose will not be eligible for warranty protection. For all warranty inquiries or claims please address your claim to the dealer that you
purchased the product from – or to Solid State Logic if the purchase was directly from Solid State Logic – within a period of two months from the
date on which you detected its lack of conformity with the terms of the warranty. Please include your original proof of purchase when initiating the claim.
Within the EU: Pursuant to the Solid State Logic Terms and Conditions under European consumer law the purchaser has full statutory warranty rights for two
years from the date of delivery of the product. The warranty is valid only in those Member States of the European Union (EU) who have adopted
the applicable EU law into their national legislation. The applicable national legislation governing the sale of consumer goods is not affected
by this warranty.
Outside of the EU: Outside of the European Union a  month warranty from date of purchase is applicable.
Out of Warranty Repairs
In the event of a fault arising after the warranty period has expired the unit should be returned to Solid State Logic either directly or via your local dealer. You will be
charged for the time spent on the repair (at Solid State Logic's current repair rate) plus the cost of parts and shipping. Note that no units can be accepted for repair
without prior arrangement (see below).
All Returns
No unit will be accepted for repair by Solid State Logic unless accompanied by a valid RMA (Return Material Authorisation) number, obtainable from Solid State Logic
prior to shipping.
All units should be shipped to Solid State Logic in suitable rigid packaging – Solid State Logic cannot be held responsible for any damage caused by shipping units
in other packaging. In such cases Solid State Logic will return the unit in a suitable box, which you will be charged for.
Do not include the power cable, manual or any other items – Solid State Logic can not guarantee to return them to you.
82BMSGX1A Sigma Install 4_Print Layout 09/07/2013 11:05 Page 6
EN
DE
ES
FR
IT
JP
Specifications
Physical *
Depth mm / ." casing only
Height mm / ." ( RU)
Width mm / " casing only
mm / " inc’ rack ears
Weight kg /  pounds
Power <  Watts
Boxed size mm x mm x mm
" x ." x "
Boxed weight kg /  pounds
* All values are approximate
Environmental
Temperature Operating: + to  deg. C
Non-operating: – to  deg. C
Max. gradient:  deg. C/hour
Relative Operating:  to %
Humidity Non-operating:  to %
Max. wet bulb:  deg. C
(non-condensing)
Vibration Operating: < . G ( – Hz)
Non-operating: < . G ( – Hz)
Shock Operating: <  G (ms max.)
Non-operating: <  G (ms max.)
Altitude Operating:  to m
(above sea level) Non-operating:  to m
Connections
Power Supply IEC -pin connector,  –  Vac,  –  Hz
DC Power mm DC power jack, +V, < A
Analogue I/O -pin D-type socket, balanced, Zin > kΩ, Zo Ω
-pin XLR-M, balanced, Zo ≈ Ω
Headphones Stereo /" jack socket, Zo ≈ Ω
Footswitch Stereo /" jack socket ( circuit)
iJack Stereo .mm jack socket, Zi ≈ k
Network Pc modular connector; ‘RJ-’ type (bT, Cat)
USB  x type-B chassis socket (SSL diagnostic use only)
Performance
Maximum I/O Level +dBu, +dBu or dBu
Frequency Response Hz – kHz ±.dB
THD + N < .% (Hz – kHz)
Noise
CHIP to CHOP < –dBu @ +dBu (Hz – kHz)
CHIP to MIX A < dBu @ +dBu (Hz – kHz)
(stereo, all channels routed)
Electro Magnetic Compatibility
EN-:, EN-:
Environment E
Initial in-rush current A
 sec in-rush current A
Braid-screened cables should be used where applicable
Star Quad cables should be used where applicable
EMC Performance Criteria
Line level inputs and outputs
Measure at mid-gain, noise <–dBu
82BMSGX1A Sigma Install 4_Print Layout 09/07/2013 11:05 Page 7
82BMSGX1A Sigma Install 4_Print Layout 09/07/2013 11:05 Page 8

82BMSGX1A Sigma Install 4_Print Layout 09/07/2013 11:05 Page 16

82BMSGX1A Sigma Install 4_Print Layout 09/07/2013 11:06 Page 32

82BMSGX1A Sigma Install 4_Print Layout 09/07/2013 11:06 Page 40

82BMSGX1A Sigma Install 4_Print Layout 09/07/2013 11:06 Page 48

EN
DE
ES
FR
IT
JP
Connectors
Channels 1 – 4 illustrated, channels 5 thru 16 follow a similar pattern in blocks of 4 stereo channels.
D-type connector wiring follows AES59 (‘Tascam’) standard and binding posts are 4-40 UNC thread.
‘CHIP’ – Channel Input Connectors
Connector Type: -way D-type Female
Pin Description
Channel  Right (+ve)
 Channel  Right (–ve)
V
 Channel  Left (+ve)
Channel  Left (–ve)
 V
Channel  Right (+ve)
 Channel  Right (–ve)
V
 Channel  Left (+ve)
Channel  Left (–ve)
 V
Channel  Right (+ve)
 Channel  Right (–ve)
V
 Channel  Left (+ve)
Channel  Left (–ve)
 V
 Channel  Right (+ve)
 Channel  Right (–ve)
 V
 Channel  Left (+ve)
 Channel  Left (–ve)
 V
 n/c
‘CHOP’ – Channel Output Connectors
Connector Type: -way D-type Female
Pin Description
Channel  Right (+ve)
 Channel  Right (–ve)
V
 Channel  Left (+ve)
Channel  Left (–ve)
 V
Channel  Right (+ve)
 Channel  Right (–ve)
V
 Channel  Left (+ve)
Channel  Left (–ve)
 V
Channel  Right (+ve)
 Channel  Right (–ve)
V
 Channel  Left (+ve)
Channel  Left (–ve)
 V
 Channel  Right (+ve)
 Channel  Right (–ve)
 V
 Channel  Left (+ve)
 Channel  Left (–ve)
 V
 n/c
82BMSGX1A Sigma Install 4_Print Layout 09/07/2013 11:06 Page 49

D-type connector wiring follows AES59 (‘Tascam’) standard and binding posts are 4-40 UNC thread.
Connectors (continued)
EXT, RTNS, T/B
D-sub to XLR-F
Loom
Connector Type: -way D-type Female
Pin Description
n/c
XLR- n/c
V
 Talkback Mic Input (+ve)
XLR- Talkback Mic Input (–ve)
 V
Mix B Insert Return Right (+ve)
XLR- Mix B Insert Return Right (–ve)
V
 Mix B Insert Return Left (+ve)
XLR- Mix B Insert Return Left (–ve)
 V
Mix A Insert Return Right (+ve)
XLR- Mix A Insert Return Right (–ve)
V
 Mix A Insert Return Left (+ve)
XLR- Mix A Insert Return Left (–ve)
 V
 External Input Right (+ve)
XLR- External Input Right (–ve)
 V
 External Input Left (+ve)
XLR- External Input Left (–ve)
 V
 n/c
MIX B, SENDS, H/P
D-sub to XLR-M
Loom
Connector Type: -way D-type Female
Pin Description
Headphone Right (+ve, line level)
XLR- Headphone Right (–ve, line level)
V
 Headphone Left (+ve, line level)
XLR- Headphone Left (–ve, line level)
 V
Mix B Insert Send Right (+ve)
XLR- Mix B Insert Send Right (–ve)
V
 Mix B Insert Send Left (+ve)
XLR- Mix B Insert Send Left (–ve)
 V
Mix A Insert Send Right (+ve)
XLR- Mix A Insert Send Right (–ve)
V
 Mix A Insert Send Left (+ve)
XLR- Mix A Insert Send Left (–ve)
 V
 Mix B Output Right (+ve)
XLR- Mix B Output Right (–ve)
 V
 Mix B Output Left (+ve)
XLR- Mix B Output Left (–ve)
 V
 n/c
82BMSGX1A Sigma Install 4_Print Layout 09/07/2013 11:06 Page 50
EN
DE
ES
FR
IT
JP
Connectors (continued)
Main Monitor Output
Connector Type: XLR -pin Male
Pin Description
V (Chassis)
Signal +ve
Signal –ve
iJack Input
Connector Type: .mm Stereo Jack
Description
Tip Signal Left
Ring Signal Right
Sleeve V (Chassis)
Headphones
Connector Type: ." Stereo Jack
Description
Tip Signal Left
Ring Signal Right
Sleeve V (Chassis)
Alternate Monitor Output
Connector Type: XLR -pin Male
Pin Description
V (Chassis)
Signal +ve
Signal –ve
Mix A Output
Connector Type: XLR -pin Male
Pin Description
V (Chassis)
Signal +ve
Signal –ve
Foot Switch Input
Connector Type: ." Stereo Jack
Description
Tip Signal
Ring V (Chassis)
Sleeve V (Chassis)
82BMSGX1A Sigma Install 4_Print Layout 09/07/2013 11:06 Page 51
Visit SSL at: www.solidstatelogic.com
BMSGXA
© Solid State Logic
All Rights reserved under International and Pan-American Copyright Conventions
SuperAnalogue, XLogic, SSL and Solid State Logic are trademarks of Solid State Logic
All other product names and trademarks are the property of their respective owners and are hereby acknowledged
No part of this publication may be reproduced in any form or by any means, whether mechanical or electronic, without
the written permission of Solid State Logic, Oxford, OX RU, England
As research and development is a continual process, Solid State Logic reserves the right to change the features and
specifications described herein without notice or obligation.
Solid State Logic cannot be held responsible for any loss or damage arising directly or indirectly from any error or
omission in this manual.
E&OE
82BMSGX1A Sigma Install 4_Print Layout 09/07/2013 11:06 Page 52
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55

Solid State Logic Sigma Delta Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI