ESAB LAE 1250 User manual

Type
User manual

This manual is also suitable for

-- 4 --
Rรคtt till รคndring av specifikationer utan avisering fรถrbehรฅlles.
Ret til รฆndri ng af specifikationer uden varsel forbehol des.
Rett til รฅ endre spesifi kasjoner uten varsel forbeholdes.
Oikeudet muutoksiin pidรคtetรครคn.
Rights reserved to alter specifications without notice.
ร„nderungen vorbehalten.
Sous rรฉserve de modifications sans avis prรฉalable.
Recht op wijzigingen zonder voorafgaande mededeling voorbehouden.
Reservado el derecho de cambiar las especificaciones sin previ o aviso.
Ci riserviamo il diritto di variare le specifiche senza preavviso.
Reservamo--nos o direito de alterar as especificaรงรตes sem aviso prรฉvi o.
ร„รฉรกรดรงรฑรฅรŸรดรกรฉ รดรฏ รครฉรชรกรŸรนรฌรก รดรฑรฏรฐรฏรฐรฏรŸรงรณรงรฒ รฐรฑรฏรครฉรกรฃรฑรกรถรพรญ ร—รนรฑรŸรฒ รฐรฑรฏรฅรฉรครฏรฐรฏรŸรงรณรง.
SVENSKA 5..............................................
DANSK 11................................................
NORSK 17................................................
SUOMI 23................................................
ENGLISH 29..............................................
DEUTSCH 35.............................................
FRANร‡AIS 41.............................................
NEDERLANDS 47.........................................
ESPAร‘OL 53..............................................
ITALIANO 59..............................................
PORTUGUรŠS 65..........................................
ร…ร‹ร‹ร‡รร‰รŠร 71.............................................
SVENSKA
-- 5 --
TOCs
1 INDLEDNING 6......................................................
1.1 TEKNISK BESKRIVNING 7..................................................
1.2 TEKNISKA DATA LAE 1250 7................................................
1.3 TEKNISKA DATA LAE 1600 8................................................
1.4 INSTALLATION 9...........................................................
1.5 DRIFT 10...................................................................
1.6 UNDERHร…LL 10.............................................................
SCHEMA 77.............................................................
RESERVDELSFร–RTECKNING 79.........................................
DANSK
-- 1 1 --
TOCd
1 INDLEDNING 12......................................................
1.1 TEKNISK BESKRIVELSE 13..................................................
1.2 TEKNISKE DATA LAE 1250 13................................................
1.3 TEKNISKE DATA LAE 1600 14................................................
1.4 INSTALLATION 15...........................................................
1.5 DRIFT 16...................................................................
1.6 VEDLIGEHOLDELSE 16......................................................
SKEMA 77..............................................................
RESERVEDELSFORTEGNELSE 79........................................
NORSK
-- 1 7 --
TOCn
1 INNLEDNING 18......................................................
1.1 TEKNISK BESKRIVELSE 19..................................................
1.2 TEKNISKE DATA LAE 1250 19................................................
1.3 TEKNISKE DATA LAE 1600 20................................................
1.4 INSTALLERING 21...........................................................
1.5 DRIFT 22...................................................................
1.6 VEDLIKEHOLD 22...........................................................
SKJEMA 77.............................................................
RESERVEDELSLISTE 79.................................................
ENGLISH
-- 2 9 --
TOCe
1 INT RODUCTION 30...................................................
1.1 TECHNICAL DESCRIPTION 31................................................
1.2 TECHNICAL DATA LAE 1250 31..............................................
1.3 TECHNICAL DATA LAE 1600 32..............................................
1.4 INSTALLATION 33...........................................................
1.5 OPERATION 34.............................................................
1.6 MAINTENANCE 34...........................................................
DIAGRAM 77............................................................
SPARE PARTS LIST 79...................................................
-- 3 0 --
ba13d12e
1 INTRODUCTION
LAE is a constant voltage welding rectifier. It is designed SOLELY for submerged
arc and gas metal welding (MIG/MAG).
LAE is designed for use with PEG --1 control equipment.
The welding current range can be extended by connecting two welding rectifiers in
parallel. To ensure the correct division of current between welding rectifiers a
parallel operation device is required. (Order no. 321 181--880).
WARNING
This product is intended for industrial use. In a domestic environment this product
may cause radio interference. It is the users responsibility to take adequate pre-
cautions.
WARNING
READ AND UNDERSTAND THE INSTRUCTION MANUAL BEFORE INSTALLING OR OPERATING.
ARC WELDING AND CUTTING CAN BE INJURIOUS TO YOURSELF AND OTHERS. TAKE PRECAU -
TIONS WHEN WELDING. ASK FOR YOUR EMPLOYERโ€™S SAFETY PRACTICES WHICH SHOULD BE
BASED ON MANUFACTURERSโ€™ HAZARD DATA.
ELECTRIC SHOCK -- Can kill
S Install and earth the welding unit in accordance with applicable standards.
S Do not touch live electrical parts or electrodes with bare skin, wet gloves or wet clothing.
S Insulate yourself from earth and the workpiece.
S Ensure your working stance is safe.
FUMES AND GASES -- Can be dangerous to health
S Keep your head out of the fumes.
S Use ventilation, extraction at the arc, or both, to keep fumes and gases from your breathing zone and
the general area.
ARC RAYS -- Can injure eyes and burn skin.
S Protect your eyes and body. Use the correct welding screen and filter lens and wear protective
clothing.
S Protect bystanders with suitable screens or curtains.
FIRE HAZARD
S Sparks (spatter) can cause fire. Make sure therefore that there are no inflammable materials nearby.
NOISE -- Excessive noise can damage hearing
S Protect your ears. Use ear defenders or other hearing protection.
S Warn bystanders of the risk.
MALFUNCTION -- Call for expert assistance in the event of malfunction.
PROTECT YOURSELF AND OTHERS!
GB
-- 3 1 --
ba13d12e
1.1 TECHNICAL DESCRIPTION
LAE is a fan--cooled welding rectifier. It is fitted with a thermal cut--out to provide
protection against overloading or failure of the fan.
If this cut --out is activated a yellow lamp on the front panel lights up automatically.
When the rectifier has cooled down the cut--out is automatically reset.
1.2 TECHNICAL DATA LAE 1250
Mains supply 50 Hz 60 Hz
Voltage (V) 230/400/415/500 230/440/550
Primary current (A) 171/99/99/80 171/99/80
Fuse, slow (A) 200/125/125/80 200/100/80
Power cable, area (mm
2
) 230V 2// 3x35+25
alt.3x95+50
2// 3x35+25
alt.3x95+50
Power cable, area (mm
2
) 400/415V 3x35+25
Power cable, area (mm
2
) 500V 3x25+16
Power cable, area (mm
2
) 440V 3x35+25
Power cable, area (mm
2
) 550V 3x25+16
Maximum load at
100 % duty cycle 1250 A / 44 V
Settings range 40 A / 22 V--1250 A / 44 V
Open circuit voltage 51 V
Open circuit power 220 W
Power factor at maximum current 0,92
Efficiency at maximum current 87 %
Enclosure class IP 23
Application class
Weight 490 kg
Dimensions lxbxh 774x598x1228
-- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --------
Welding power source complies with IEC 974--1
Power cable rating complies with Swedish regulations.
The symbol
indicates that the power source is designed for use in areas where
there is an increased electrical hazard.
The IP code indicates the enclosure class, i. e. the degree of protection against
penetration by solid objects or water.
Equipment marked IP 23 is designed for indoor and outdoor use.
GB
-- 3 2 --
ba13d12e
1.3 TECHNICAL DATA LAE 1600
Mains supply 50 Hz 60 Hz
Voltage (V) 230/400/415/500 230/440/550
Primary current (A) 235/136/136/108 235/136/108
Fuse, slow (A) 250/160/160/125 250/160/125
Power cable, area (mm
2
) 230V 2// 3x50+35
alt.3x150+95
2// 3x35+25
alt.3x150+95
Power cable, area (mm
2
) 400/415V 3x70+35
Power cable, area (mm
2
) 500V 3x50+35
Power cable, area (mm
2
) 440V 3x70+35
Power cable, area (mm
2
) 550V 3x70+35
Maximum load at
100 % duty cycle 1600 A / 44 V
Settings range 40 A / 22 V--1600 A / 48 V
Open circuit voltage 54 V
Open circuit power 220 W
Power factor at maximum current 0,87
Efficiency at maximum current 86 %
Enclosure class IP 23
Application class
Weight 585 kg
Dimensions lxbxh 774x598x1228
-- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --------
Welding power source complies with IEC 974--1
Power cable rating complies with Swedish regulations.
The symbol
indicates that the power source is designed for use in areas where
there is an increased electrical hazard.
The IP code indicates the enclosure class, i. e. the degree of protection against
penetration by solid objects or water.
Equipment marked IP 23 is designed for indoor and outdoor use.
GB
-- 3 3 --
ba13d12e
1.4 INSTALLATION
1. Installation must be carried out by a qualified electrician.
2. Make sure the welding rectifier is set up for the available
mains supply before connecting to the mains.
3. If the control voltage is switched between 42 V and 110 V, make sure the revers-
ible rating plate shows the correct voltage.
4. For information on power cable area and fuse size, refer to technical data.
5. Connect the power cable to the rectifier in accordance with local regulations, and
make sure the correct fuse is fitted in the fuse box.
6. Check that the cooling vents on the rectifier are not obstructed.
GB
-- 3 4 --
ba13d12e
1.5 OPERATION
S Turn the switch (1) to setting โ€Iโ€. The
white lamp (2) should light up and the fan
will start.
S Adjust the welding voltage using the knob
(3) on the front panel.
S If you are using a remote connect it to the
socket (4) on the front panel and set the
toggle switch ( 5) to the remote setting.
S Choose a suitable welding cable and re-
turn cab le and connect these to + and --
on the front of the machine. Connect the
return cable to the work piece.
S T he r ectifier is now ready for welding.
S 8 pin socket for external control (6)
S 1 pin socket for meter cable (7)
S Space for digital meters (8) (optional)
S Yellow lamp (9) (overload cut--out)
1.6 MAINTENANCE
Blow the power source clean at least once a year using dry compressed air at
reduced pressure.
If the power source is used in a dusty or dirty environment it should be blown clean
more often.
Spare parts are ordered through your nearest ESAB representative, see back cover.
When ordering spare parts, please state machine type and number as well as desig-
nation and spare part number as shown in the spare parts list on page 79.
This will simplify dispatch and ensure you get the right part.
GB
ba13d001
DEUTSCH
-- 3 5 --
TOCg
1 EINLEITUNG 36.......................................................
1.1 TECHNISCHE BESCHREIBUNG 37...........................................
1.2 TECHNISCHE DATEN 1250 37................................................
1.3 TECHNISCHE DATEN 1600 38................................................
1.4 INSTALLATION 39...........................................................
1.5 BETRIEB 40.................................................................
1.6 WARTUNG 40...............................................................
SCHALTPLAN 77........................................................
ERSATZTEILLISTE 79....................................................
FRANร‡AIS
-- 4 1 --
TOCf
1 INT RODUCTION 42...................................................
1.1 DESCRIPTION TECHNIQUE 43...............................................
1.2 CARACTร‰RISTIQUES TECHNIQUES LAE 1250 43..............................
1.3 CARACTร‰RISTIQUES TECHNIQUES LAE 1600 44..............................
1.4 INSTALLATION 45...........................................................
1.5 MISE EN SERVICE 46........................................................
1.6 ENTRETIEN 46..............................................................
SCHร‰MA 77.............................................................
LISTE DE PIรˆCES Dร‰TACHร‰ES 79........................................
NEDERLANDS
-- 4 7 --
TOCh
1 INLEIDING 48.........................................................
1.1 TECHNISCHE BESCHRIJVING 49.............................................
1.2 TECHNISCHE GEGEVENS 1250 49...........................................
1.3 TECHNISCHE GEGEVENS 1600 50...........................................
1.4 INSTALLATIE 51.............................................................
1.5 GEBRUIK 52................................................................
1.6 ONDERHOUD 52............................................................
SCHEMA 77.............................................................
RESERVEONDERDELENLIJST 79.........................................
ITALIANO
-- 5 9 --
TOCi
1 INT RODUZIONE 60...................................................
1.1 DESCRIZIONE TECNICA 61..................................................
1.2 CARATTERISTICHE TECNICHE 1250 61.......................................
1.3 CARATTERISTICHE TECNICHE 1600 62.......................................
1.4 INSTALLAZIONE 63..........................................................
1.5 USO 64.....................................................................
1.6 MANUTENZIONE 64.........................................................
SCHEMA 77.............................................................
ELENCO RICAMBI 79....................................................
PORTUGUรŠS
-- 6 5 --
TOCp
1 INTRODUร‡รƒO 66.....................................................
1.1 DESCRIร‡รƒO Tร‰CNICA 67....................................................
1.2 DADOS Tร‰CNICOS 1250 67..................................................
1.3 DADOS Tร‰CNICOS 1600 68..................................................
1.4 INSTALAร‡รƒO 69.............................................................
1.5 OPERAร‡รƒO 70..............................................................
1.6 MANUTENร‡รƒO 70...........................................................
ESQUEMA 77...........................................................
LISTA DE PEร‡AS SOBRESSALENTES 79..................................
-- 8 0 --
s320883
Item
no.
Qty Ordering no. Denomination Notes
0320883880 Welding power source LAE 1250
0320883881 Welding power source LAE 1250
1 1 0320746002 Main switch
2 1 0192576004 Indicating lamp
3 0192576304 Indicating lamp (yellow) 42 -- 48 V
4 1 0147866001 Switch
5 1 0218810781 Knob
6 2 0156388001 Handle
8 1 0481531880 PC--board
9 1 0481097880 PC-- board
10 3 0567200610 Fuse 16 A
11 1 0442849880 Contactor 150 A, 1000 V
12 3 0319828001 Transformer
14 1 0319470015 Control transformer 42/110 V
15 2 0158115880 Cable inlet
-- 8 1 --
s320883
Item
no.
Qty Ordering no. Denomination Notes
1 1 0191085105 Capacitor 5 ยตF, 400 V
2 3 0490600606
S
ilicon diode
3 1 0320445882 Inductor
4 1 0320444882 Coil (inductor)
5 1 0320951001 Fan
6 3 0320924882 Thyristor bridge
7 4 0041051606 Transient protection
8 3 0320946001 Thyristor 1100 A / 300 V
9 1 0040887080 Current relay
10 1 0320447880 Shunt
-- 8 2 --
s320883
Item
no.
Qty Ordering no. Denomination Notes
1 6 0490600626
S
ilicon diode
2 1 0469845880 Transformer
3 3 0469842880 Transformer coil
-- 8 3 --
s320984
Item
no.
Qty Ordering no. Denomination Notes
0320984880 Welding power source LAE 1600
0320984882 Welding power source LAE 1600
1 1 0320746002 Main switch
2 1 0192576004 Indicating lamp
3 1 0192576304 Indicating lamp (yellow) 42 -- 48 V
4 1 0147866001 Switch
5 1 0218810781 Knob
6 2 0156388001 Handle
8 1 0481531880 PC--board
9 1 0481097880 PC--board
10 1 0567200610 Fuse 16 A
11 1 0442849880 Contactor 265 A, 1000 V
12 3 0319828001 Transformer
14 1 0319470015 Control transformer 42/110 V
15 2 0158115880 Cable inlet
-- 8 4 --
s320984
Item
no.
Qty Ordering no. Denomination Notes
1 1 0191085105 Capacitor 5 ยตF, 400 V
2 3 0490600606 Silicon dide
3 1 0320445883 Inductor
4 1 0320444883 Coil (inductor)
5 1 0320951001 Fan
6 3 0321452880 Thyristor bridge
7 4 0041051606 Transient protection
8 3 0321427001 Thyristor 1500 A / 500 V
9 1 0040887080 Current relay
10 1 0320447880 Shunt
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86

ESAB LAE 1250 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI