Commercial Electric GHR8991AL-NTMG Operating instructions

Type
Operating instructions

This manual is also suitable for

Page 1
INSTRUCTION MANUAL
1LT Interior Mini-Pendant
Home Depot SKU 228-248 (UPC 6940500311579) (brushed nickel)
Home Depot SKU 228-564 (UPC 6940500311586) (nutmeg)
Page 2
Thank you for purchasing this Commercial Electric interior mini-pendant.
This product has been manufactured with the highest standards of safety and
quality.
FEATURES:
1. One-light mini-pendant in brushed nickel finish (SKU 228-248) or nutmeg
finish (SKU 228-564) and frosted ribbed glass.
2. This fixture has been engineered to safely use up to a 60 watt medium
base incandescent light bulb (do not exceed 60 watts) (not included).
3. For energy savings, this fixture has been engineered to safely use a
standard base compact fluorescent light bulb (do not exceed 15 watts) (not
included).
QUESTIONS, PROBLEMS, MISSING PARTS:
Before returning to your local Home Depot, please call our Customer Service
Team at 1-877-527-0313 or visit www.homedepot.com. Please reference your
SKU (228-248 brushed nickel fixture, 228-564 nutmeg fixture) or UPC
(6940500311579 brushed nickel fixture, 6940500311586 nutmeg fixture).
Page 3
CAUTION:
1. Before starting installation of this fixture or removal of a previous fixture,
disconnect the power by turning off the circuit breaker or by removing the
fuse at the fuse box.
2. CONSULT A QUALIFIED ELECTRICIAN IF YOU HAVE ANY
ELECTRICAL QUESTIONS.
3. If you have any non-electrical questions about this fixture, please contact
our Customer Service Team at 1-877-527-0313 or visit
www.homedepot.com. Please reference your SKU (228-248 brushed nickel
fixture, 228-564 nutmeg fixture) or UPC (6940500311579 brushed nickel
fixture, 6940500311586 nutmeg fixture).
4. Keep your receipt and these Instructions for Proof of Purchase.
TOOLS REQUIRED FOR ASSEMBLY & INSTALLATION
(not included):
Light Bulb Safety goggles Ladder Gloves Wire strippers
(60 watt maximum)
(or CFL equivalent)
Flathead screwdriver Phillips screwdriver Electrical tape Wire cutters
Page 4
PARTS INCLUDED FOR ASSEMBLY (parts are not to scale):
1ea Decorative Pan (#16) 1ea Canopy (#8) 3ea Tubes (#11, #13, #15) 1ea Shade (#19)
Bushing (#9)
1ea Socket Ring (#20)
ASSEMBLY INSTRUCTIONS:
1. Carefully unpack the fixture. Lay out all parts on a clean surface.
2. Weave the fixture wires up through Tube A (#15), through Tube B (#13),
through Tube C (#11), and through the Bushing (#9) on the Canopy (#8).
The height of the fixture can be adjusted by using fewer tubes (each tube is
12 inches long).
3. Screw Tube A (#15) onto the Nipple (#17). Screw Tube B (#13) onto
Nipple A (#14). Screw Tube C (#11) onto Nipple B (#12). Screw the
Bushing (#9) onto Nipple C (#10).
4. Place the Decorative Pan (#16) on the Shade (#19).
5. Unscrew the Socket Ring (#20) from the Socket (#18). Place the Shade
(#19) over the Socket (#18). Rescrew the Socket Ring (#20) onto the
Socket (#18).
6. Install up to a 60 watt medium base incandescent light Bulb (#21) (not
included) or equivalent standard base compact fluorescent light bulb (not
included) in the Socket (#18).
Page 6
PARTS INCLUDED FOR INSTALLATION (parts are not to scale):
3ea Wire Connectors (#2) 1ea Ground Screw (#3) 1ea Mounting Strap (#4)
2ea Mounting Screws (#5) 2ea Outlet Box Screws (#6) 2ea Lock Nuts (#7)
INSTALLATION INSTRUCTIONS:
1. Screw the two Mounting Screws (#5) into the Mounting Strap (#4). Mount the Mounting
Strap (#4) to the Outlet Box (#1) using the two Outlet Box Screws (#6). [Make sure the
threads of the Mounting Screws (#5) are facing outside when the Mounting Strap (#4) is
attached to the Outlet Box (#1).]
2. Wrap the ground wire from the fixture around the Ground Screw (#3) on the Mounting
Strap (#4), and then connect the ground wire from the fixture to the ground wire from the
Outlet Box (#1).Connect the wire without writing on it (with raised ribs) from the fixture
to the white wire from the Outlet Box (#1). Connect the wire with writing on it from the
fixture to the black wire from the Outlet Box (#1). Cover the connectors using the
provided Wire Connectors (#2). Wrap the wire connections with electrical tape for a more
secure connection. Position the wires back inside the Outlet Box (#1). Note: If you have
electrical questions, consult your local electrical code for approved grounding methods.
3. Place the Canopy (#8) against the Outlet Box (#1) by aligning the protruding Mounting
Screws (#5) all the way through the holes on the Canopy (#8). Tighten the fixture to the
ceiling by screwing the two Lock Nuts (#7) onto the two protruding Mounting Screws
(#5).
4. Installation is complete. Turn on the power at the circuit breaker or fuse box. Turn the
light switch on to activate the fixture.
Page 8
TROUBLESHOOTING:
PRODUCT MAINTENANCE:
1. To clean the outside of the fixture, use a dry or slightly dampened clean cloth (use clean
water, never a solvent) to wipe the glass and surface of the fixture.
2. To clean the inside of the fixture, first disconnect power to the fixture by turning off the
circuit breaker or by removing the fuse at the fuse box. Next, use a dry or slightly
dampened clean cloth (use clean water, never a solvent) to wipe the inside glass and
interior surface of the fixture.
3. Do not use any cleaners with chemicals, solvents or harsh abrasives. Use only a dry soft
cloth to dust or wipe carefully.
LIMITED WARRANTY
The manufacturer warrants this lighting fixture to be free from defects in materials and workmanship for a period
of five (5) years from date of purchase. This warranty applies only to the original consumer purchaser and only
to products used in normal use and service. If this product is found to be defective, the manufacturers only
obligation, and your exclusive remedy, is the repair or replacement of the product at the manufacturers
discretion, provided that the product has not been damaged through misuse, abuse, accident, modifications,
alterations, neglect or mishandling. This warranty shall not apply to any product that is found to have been
improperly installed, set-up, or used in any way not in accordance with the instructions supplied with the product.
This warranty shall not apply to a failure of the product as a result of an accident, misuse, abuse, negligence,
alteration, or faulty installation, or any other failure not relating to faulty material or workmanship. This
warranty shall not apply to the finish on any portion of the product, such as surface and/or weathering, as this is
considered normal wear and tear. The manufacturer does not warrant and specially disclaims any warranty,
whether express or implied, of fitness for a particular purpose, other than the warranty contained herein.
The manufacturer specifically disclaims any liability and shall not be liable for any consequential or
incidental loss or damage, including but not limited to any labor / expense costs involved in the
replacement or repair of said product.
Problem Possible Cause Corrective Action
1. Bulb is burned out. 1. Replace light bulb.
2. Power is off. 2. Make sure power
supply is on.
3. Faulty wire connection. 3. Check wiring.
Bulb will not light.
4. Faulty switch. 4. Test or replace switch.
Fuse blows or circuit
breaker trips when light
is turned on.
Crossed wires or power wire
is grounding out.
Check wire connections.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Commercial Electric GHR8991AL-NTMG Operating instructions

Type
Operating instructions
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI