3. Control System
3.1 Main menu
Language
English
At the first start language has to be selected. Factory setting is ENGLISH. Available languages
are: Danish, Swedish, German, English, Spanish, Portug., Dutch, French, Polish. Language can
be reset/changed later by entering the installers menu (service menu).
Water
45 °C
Water temperature.
Presents current water temperature.
Evapor
5 °C
Evaporator temperature.
Shows the current evaporator temperature
Alarm
0 0 0
Alarm display. Up to 3 alarms are shown. ”0” = no alarm. For details regarding different alarms
see chapter "Alarm handling". Alarms can be reset by pressing the control button.
Status
Off
The current operating condition of the heat pump.
”off” = switched off
”Standby” = Standby
”H.Water ” = Operating
”Legionel” = 65 °C heating is ongoing
”Def.Gas”/”Def.Air”/”Def.Stop” = Defrosting
Setpoint
45 °C
Desired water temperature.
The temperature can be changed by pressing the control button (the temperature starts flashing).
Desired water temperature can then be adjusted by turning the button. Another press on the
button will confirm the new setpoint.
A normal operating temperature is between 45 °C and 55 °C.
T min
35 °C
Minimum temperature.
Lowest allowed temperature (normally about 35°C). If the water temperature is lower than ”T min”
supplementary heating will be activated until Tmin is reached. The temperature can be changed
by pressing the control button (the temperature starts flashing). Desired settings can then be
adjusted by turning the button. Another press on the button will confirm the new setpoint.
T 2 min
10 °C
Similar function to Tmin, used as “holiday function” or when the DHW HP is in “standby” mode.
T2 min protects the DHW HP and your installation against freezing. The default setting is “10°C”.
Heat
pump
HP+EL
Energy sources. The following options are available:
”OUT” = standby
”HP” = Only heat pump is allowed
”EL” = Only immersion heater is allowed
”HP+EL” = Heat pump and immersion heater in combination
”BOILER” = Only boiler is available
”HP+BOIL” = Heat pump and boiler is allowed
If no boiler is installed, the last 2 combinations can not be used.
Legionel
Off
Legionella setting. If switched (”ON”) the heat pump will once weekly increase the temperature to
65 °C, in order to prevent legionella.
FanCon
Off
Displays the fan operating mode. When set to "Off", the fan will stop together with the heat
pump. The "Low" setting is for low speed and the "High" setting is for high speed. This also
means that there is constant ventilation.
FanOper
High
Fan speed, when the heat pump is operating. ”Low” = low speed ”High” = high speed
Solarcell
Off
This function allows you to operate the DHW HP using cheap and environmentally -friendly
energy from your own solar cell panels.
"Off" = Solar cells are not connected to the system or have not been chosen to be used by the
user.
"HP only" , “EL only” and “HP + EL”: These values indicate the chosen operation mode, when
the solar cell function is activated by the external inverter signal. See the wiring diagram for the
connection to the controller.
SC-HP
52 °C
Set point temperature of “HP only” operating mode, when the solar cell function is activated
(inverter signal).
SC-EL
53 °C
Set point temperature of “EL only” and “HP + EL” operating mode, when the solar cell function is
activated (inverter signal).
Holiday
Off
This parameter activates/deactivates the holiday mode. The holiday mode can be selected with
the rotary/push button. The possible selections are:
“Off”, “1 week”, “ 2 weeks”, “3 weeks”, “3 days”, “Manual”
When the holiday mode is activated, “T2 min” is the safety level for frost protection.