GR644
Figure 8
2.4 Vertical Mounting for Pole Application.
2.4.1 Remove the lens and the door. Remove the reflector
carefully in order to maintain the electrical connections between the
reflector and the housing. See Figure 1.
2.4.2 See Figure 8 for the hole pattern that must be on the pole in
order to install this fixture. Mount the housing to the pole using two
lockwashers and two 3/8-16 fasteners provided.
2.4.3 To finish follow steps 2.2.3 through 2.2.5.
Figure 7
GR645A
2.5 Ceiling Mounting.
2.5.1 Remove the lens and the door. Remove the reflector
carefully in order to maintain the electrical connections between the
reflector and the housing. See Figure 1.
2.5.2 Remove the two knockouts for 7/16 diameter mounting holes
and mount to ceiling. See Figure 8 for the hole pattern which must
be on the mating surface in order to attach this fixture.
2.5.3 Bring the supply wires through the center 15/16 diameter
hole. For supply connections outside the housing, use wire rated
for at least 90 degrees C. For supply connections inside the
housing, use wire rated for at least 200 degrees C. Connect supply
leads to marked leads on ballast.
2.5.4 To finish follow steps 2.2.4 through 2.2.5.
2.6 Quick Install/Through Wiring Mounting.
2.6.1 Set the fixture on the hooks of the ceiling cover (shipped
separate). Make up the supply wiring connections to the lighting
fixture. Hinge the fixture up and drive in captive screw provided.
The assembly is now locked together. See Figure 9.
2.6.2 Remove the lens to insert correct lamp type into socket.
2.6.3 Attach the lens to the housing using four captive screws.
For asymmetric distribution, orient the word "Front" toward the area
to be lighted. Tighten the captive screws only until the lens
compresses the captive gasket. Do not overtighten screws.
2.7 Pendant Mounting.
2.7.1 Remove the lens and the door. Remove the reflector
carefully in order to maintain the electrical connections between the
reflector and the housing. See Figure 1.
2.7.2 Mount the housing by threading rigid conduit into 3/4-14 NPT
tapped hole in top of the housing. Lock with locknut provided. Seal
threads with water tight sealant.
2.7.3 To finish follow steps 2.2.3 through 2.2.5.
2.8 Flexible Pendant Mounting.
2.8.1 Remove the top plate from the fixture. Thread plate onto 3/
4-14 NPT hook or loop and lock with set screw provided. Orient
plate to desired position of the fixture. Seal threads with water tight
sealant. See Figure 10.
2.8.2 For supply connections, outside the housing, use wire rated
for least 90 degree C. Splice wires inside well on plate on top of
housing. Reattach the top plate to the plate on the housing using
two washers and two 1/4-20 bolts provided. Slide top plate until
the fixture hangs level. Tighten bolts.
2.8.3 Remove the lens and insert proper lamp type into socket.
2.8.4 Attach the lens to the housing using four captive screws.
For asymmetric distribution, orient the word "Front" towards area to
be lighted. Tighten the captive screws only until the lens com-
presses the captive gasket. Do no overtighten screws.
Figure 9
GR637