Auto-o Seng
• Auto-o funcon is set to 180 seconds by default.
• Auto-o can be set to 60 seconds, 120 seconds, 180
seconds, or disabled manually.
• To change the Auto-o me seng or disable this funcon:
❶ Turn o the scale.
❷ Press and hold the ON/OFF buon.
❸ While holding the ON/OFF buon, press the
TARE buon 4-5 mes quickly unl “180”
is displayed.
❹ Release both buons.
❺ Press the MODE buon to switch between
“0/60/120/180”.
◦If “0” is selected, the Auto-o funcon will
be disabled.
❻ Aer choosing the desired me, press the ON/OFF
buon again.
❼ The display will show “PASS” to conrm this seng.
❽ The scale will turn o automacally.
Note:
◦If “60”, “120”, or “180” is chosen, the scale will
turn o aer the designated number of seconds of
inacvity.
◦If the Auto-o funcon is disabled, the scale will
not shut o on its own.
Please note: To maintain a longer baery life, please
turn o the scale by pressing the ON/OFF buon aer
each use.
Silicone Pad
Use of the silicone pad is oponal. It is included to provide
addional water resistance. It also prevents slight weight
variaons caused by abrupt temperature changes on the
plaorm.
• Place the silicone pad onto the plaorm with the Brewista
logo oriented to be read le to right.
• Ensure that the pad covers the plaorm completely
without interfering with plaorm travel.
• The silicone pad is dishwasher safe (top rack).
Washing Instrucons
This scale has been treated with a water-resistant nano-
coang. However, washing the scale under running water is
not recommended. Please follow these instrucons to clean
your scale:
❶ Wash the exterior of the scale with a so, damp cloth.
❷Do not wash scale under running water.
❸ Leave scale to dry on a dish rack with LCD and buons
poinng up.
DO NOT use liquid bleach or other harsh chemicals.
DO NOT use steel wool or abrasive sponges as this can
scratch the surface.
DO NOT submerge the scale.
Avoid pouring water directly into your scale, as water
may become trapped. If this occurs drying me may
exceed 4 hours.
Water drops on the LCD display will not interfere with
your weighing. These drops will dry and disappear.
If the scale displays “UNST” or the readings jump aer
washing, then water is sll inside the scale. Simply shake
out the excess water and let your scale dry longer.
By following these washing instrucons, you will experience
shorter drying mes and your scale will provide you with years
of reliable service.
Mode 6:
(for Pour Over Brewing)
❶ Place brew vessel on the scale plaorm.
◦Weight reading goes to 0.0g (Auto-tares).
❷ Add coee grounds to the brewing vessel.
❸ Adjust the amount of coee grounds to the desired
weight.
❹ Once plaorm is stable, press the TARE buon.
❺ Start adding water to the coee grounds.
◦Count-up mer starts.
❻ Remove cup aer brewing.
◦Weight reading remains on the display for ve
(5) seconds aer removing the cup.
◦Aer a ve (5) second delay, me returns to
0’00” and weight returns to 0.0g.
Tare Funcon
• Tare funcon is disabled under “AUTO” mode.
• Under Manual modes: press the TARE buon when
needed.
❹ Remove cup aer brewing.
◦Weight reading remains on the display for ve
(5) seconds aer removing the cup.
◦Aer a ve (5) second delay, weight returns to
0.0g.
Mode 5:
(Auto-tare and Auto-mer with mer starng when liquid hits
the cup for espresso preparaon.)
❶Place cup on the scale.
◦Weight reading goes to 0.0g (Auto-tares).
❷ Push buon on espresso machine to start the shot.
◦When liquid hits the cup the mer automacally
starts to count up. To pause the mer, press
TIME buon.
❸ Remove cup aer brewing.
◦Weight reading remains on the display for ve
(5) seconds aer removing the cup.
◦Aer a ve (5) second delay, me returns to
0’00” and weight returns to 0.0g.
Calibraon
❶ While the scale is o, press and hold ON/OFF buon and
MODE buon at the same me unl LCD shows internal
code, then release the two buons.
❷ Press the MODE buon again.
◦The LCD will read “0.0g”.
❸ Place a 500g weight onto the center of the plaorm
◦The LCD will show internal code.
❹ Press MODE buon again.
❺The LCD will read “PASS”.
❻ Calibraon is complete.
Warning Messages
• “EEEE”: Overload
◦Quickly remove weight from plaorm to protect
the scale.
• “UNST”:
◦Scale is not steady during start up. Please turn o
scale, set on a stable surface and restart scale.
◦Water is inside the scale. Shake out excess water
and let dry.