Fluidmaster 4T12UCSP10 Installation guide

Type
Installation guide

This manual is also suitable for

Fluidmaster, Inc. at 30800 Rancho Viejo Road, San Juan Capistrano, CA 92675 (949) 728-2000, Fax (949) 728-2205.
Red/Green color arrangement is a registered trademark of Fluidmaster, Inc.
© 2011 Fluidmaster, Inc. ® Registered trademark of Fluidmaster, Inc.
U.S. and Other Patents Pending.
06/11 FM91233 Rev.2
The "CLICK"
Let's You Know
It's Sealed!
Patent pending Click Seal
nut clicks when connector
has proper seal
Click Seal nut won't crack
due to overtightening
Stainless steel braiding
protects against
burst failures
1. Turn off water supply at shutoff valve.
2. Remove old supply connector and clean all connector threads.
3. Thread the metal nut onto the shutoff valve and tighten 1/2 turn beyond hand-tight.
4. Prior to threading plastic nut onto fill valve shank, turn Click Seal nut counter-clockwise
until threads align. Gently turn Click Seal nut clockwise and hand tighten until nut
clicks. The "click" lets you know it’s sealed!
5. Slowly turn on water at the shutoff valve.
6. Carefully check for leaks at shutoff valve. If leak appears, tighten nut just enough to
provide a leak-free joint. Do not overtighten shut off valve.
(Burst) Strength: Up to 1500 PSI Torque Rating: 15-20 in-lbs
INSTALLATION INSTRUCTIONS
Fill Valve
Inlet
Shutoff
Valve
TWIST
TWIST
SEAL
SEAL
“CLICK”
“CLICK”
Technology You Can Trust - Hear the "click"
and know the toilet connector is properly
sealed and cannot be overtightened
Toilet Connector nut clicks & stops tightening
when connector has achieved a good seal
Prevents overtightening & cracking of
connector nut and fill valve shank
Stainless steel braiding provides maximum
protection against bursting
U.S. and Other Patents Pending
MODEL Shutoff Valve Ballcock CASE PRODUCT DIMENSIONS CASE DIMENSIONS CASE UPC SCCI 2 OF5
NUMBER Connection Connection Length QTY H/W/D (INCHES) H/W/D (INCHES) WEIGHT (LBS) 0 39961 100 39961
B1T09CS 3/8" Compression 7/8" Ballcock 9" 25 1 x 2.5 x 9.5 4.125 x 6.875 x 18 5.5 41181 5 42181 1
B1T12CS 3/8" Compression 7/8" Ballcock 12" 25 1 x 2.5 x 12.5 4.125 x 6.875 x 22 6.5 41182 2 40185 1
B1T16CS 3/8" Compression 7/8" Ballcock 16" 25 1 x 2.5 x 16.5 4.125 x 6.875 x 22 7.5 04336 8 01103 6
B1T20CS 3/8" Compression 7/8" Ballcock 20" 15 1 x 2.5 x 20.5 4.125 x 6.875 x 22 5.8 41184 6 42184 2
B4T09UCS 7/8" Ballcock 9" 25 1 x 2.5 x 9.5 4.125 x 6.875 x 18 6.0 41194 5 41194 2
B4T12UCS 7/8" Ballcock 12" 25 1 x 2.5 x 12.5 4.125 x 6.875 x 22 7.0 41195 2 41195 9
B4T20UCS 7/8" Ballcock 20" 15 1 x 2.5 x 20.5 4.125 x 6.875 x 22 5.0 01197 8 01197 5
3/8" C, 7/16" C,
1/2" C, 1/2" FIP
3/8" C, 7/16" C,
1/2" C, 1/2" FIP
3/8" C, 7/16" C,
1/2" C, 1/2" FIP
  • Page 1 1

Fluidmaster 4T12UCSP10 Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI