1. Introduction
Manufactured to the highest standards, these enclosures offer weatherproof protection to IP66 of
BS EN.60529 and are supplied with an adjustable bracket.
Camera fitment
1. Dennard 2010 - Unscrew 3 captive cover fixing screws (C) and remove the enclosure cover (A)
from the base (B).
Dennard 2015 - Unscrew 4 cover fixing screws (C) and remove the enclosure cover (A) from
the base (B).
2. Release the keyhole screws (D) and slide and withdraw the camera platform (E) from the base.
3. Mount camera (F) onto platform using the 1/4”UNC fixing (I) supplied as shown, ensuring the
fixing insulation bush (J) is between the camera fixing and the platform and the camera
insulation pad (G) is mounted between the platform and the camera. These items isolate the
camera from the surrounding metal work.
4. Finally, wire camera to rear terminal block using circuit diagram for terminal designations.
C
A
F
E
F
G
E
J
I
D
B
Fig.1 Camera fitment
Model Shown: Denanrd 2015
Dennard 2010/2015 Installation Manual Page. 2
2. Mounting Configuration
Enclosure mounting
1. Use bracket arm (E) as a template for marking the position of mounting holes. Remove & drill to
pattern required.
2. Attach bracket arm to wall using rawl plugs and screws provided. ( Assuming masonary wall )
3. Feed cables through bracket exiting down (C) or through (A) wall, via conduit, as req’d. (fig 2)
4. Release screw F to pan housing and screw H for tilt. Position as required for camera coverage
& tighten to secure.
5. An optional Infra red lamp (Dennard 880/883) may be mounted under the housing.
Fig.2 Mounting configuration
Model Shown: Dennard 2015
E
A
C
F
H
95071 - Wiper Assembly 230v
95072 - Wiper Assembly 110v
95073 - Wiper Assembly 24v
95074 - Wiper Arm Assembly
H003 - Wiper Blade
Option (Dennard 2015 only)
Dennard 2010/2015 Installation Manual Page. 3
3. Wiring Diagram - Dennard 2010
Fig.3 shows the internal wiring diagram for the window demister. A spare 6 way terminal block is
provided at the rear of the enclosure for camera and lens connections. Circuit idents as follows:
TB.1 6 way terminal block PTC Heater 6W (12V-24Va.c.)
FTB.1 Fused terminal block Heater 6W (110V-230Va.c.)
FS.1 3 Amp. Fuse
The information contained in this document is for guidance only.
Specification and availability of goods are subject to change without notice.
Fig.3 Wiring diagram - Dennard 2010
Housing dimensions
Measurements in mm
CUSTOMER
WIRING
BLUE
BROWN
MAIN EARTH
POINT
COVER
Inside
310 Inside
365 REF
114 REF
125 REF
Dennard 2010/2015 Installation Manual Page. 4
3. Wiring Diagram - Dennard 2015
Fig.4 shows the internal wiring diagram for the window demister. A 12 way terminal block is
provided at the rear of the enclosure for camera and lens connections. Circuit idents as follows:
TB.1 12 way terminal block PTC Heater 6W (12V-24Va.c.)
Heater 6W (110V-230Va.c.)
The information contained in this document is for guidance only.
Specification and availability of goods are subject to change without notice.
Fig.4 Wiring diagram - Dennard 2015
Measurements in mm
Housing
dimensions
Wiper unit
not included
MAIN EARTH
POINT
COVER
LOW TEMP OPTION ONLY
REF.DRG.81002
OPTIONAL WIPER
REF.DRG.80006
FRONT EARTH
POINT
GREEN/YELLOW
BLUE
BROWN
RED/BLACK
YELLOW
OPTION TAMPER SWITCH
REF. DRG. 81001
BLACK
WHITE
CUSTOMER
WIRING
440 REF
365 INSIDE
137 REF
105 INSIDE
138 REF
120 INSIDE
74 0028
Issue 4
www.dedicatedmicros.com
UK Technical Help
Dennard Limited
Unit 4, Park Iron Works, Kingsley, Nr Bordon,
Hampshire GU35 9LY
Tel: +44 (0)1420 485713 Fax: +44 (0)1420 485714
e-mail: sales@dennard-cctv.com
European Technical Help
Dedicated Micros Europa
Neckarstraße 15, 41836 Hückelhoven, Deutschland
Tel.: +49 (0) 24 33 52 58 26 Fax: +49 (0) 24 33 52 58 20.
Dedicated Micros France
9-13 rue du Moulinet, 75013 Paris, France
Tél. : +33 1 45 81 99 99, Fax : +33 1 45 81 99 89.
Dedicated Micros Belgique
Joseph Chantraineplantsoen 1, 3070 Kortenberg, Belgique
Tél. : +32 2751 3480, Fax : +32 2751 3481
Dedicated Micros Ltd. Slovenija
Delavska cesta 26, 4208 Sencur-Slovenija
Tel: +386 (4) 279 18 90, Fax: +386 (4) 279 18 91
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Dedicated Micros 2015 Camera Housings Installation guide

Category
Security camera accessories
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI