  • Hello! I am an AI chatbot trained to assist you with the Command access PD10-UL-M-KIT Insert Instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Kit Includes Tools Required
Cordless Drill or Phillips
Screwdriver
Hacksaw
A.
B.
C.
Motor Mount w/MM4
1- 8’ Lead w/ Connector
2 - Sets of nished phillips screws
Command Access Technologies | 22901 La Palma Ave, Yorba Linda, CA 92887 | Phone:(888) 622-2377
PD10-UL-M-KIT
INSERT INSTRUCTIONS
The PD10-UL-M-KIT is a eld installable motorized latch pullback for the
PD10/11, Doromatic or Falcon 1690/1790, & First Choice 3600/3700.
C.
A.
B.
#20410_B
PTS Video
Click or Scan
Techni cal in formaTion
SPECIFICATIONS
US CUSTOMER SUPPORT1-888-622-2377 | WWW.COMMANDACCESS.COM | CA CUSTOMER SUPPORT 1-855-823-3002
Select your preferred torque mode (ships in standard torque) Press the device push pad
to the desired setting. (Recommend to fully depress and release 5%, giving the device
room for changing door conditions.)
Step 2- While depressing the push pad, apply power. (i.e. presenting the credential to the reader).
Step 3- Continue to keep pad depressed, the device will beep 6 times. After the beeps have stopped,
release the pad and now the adjustment is complete. If not to your liking repeat the 3 steps.
Step 4- Once you found the correct location, turn PTS switch to OFF position.
Setting PTS
**Important Info**
Make sure to set PTS before nishing installation
Step 1-
Troubleshooting & Diagnostics
Beeps Explanation Solution
Average Latch Retraction Current: 2 A
Average Holding Current: 250 mA
High Torque Mode
Average Latch Retraction Current: 1.3 A
Average Holding Current: 215 mA
Standard Torque Mode
MM4 Switches
ON
ON
OFF
STANDARDTORQUE
HIGH TORQUE
PTS Programing Lock
PTS PROGRAMING On
OFF
Input Voltage: 24VDC +/- 10%
Wire gauge: Minimum 18
gauge
Direct wire run - no relays or
access control units in-between
power supply & module
1
2
2 Beeps
3 Beeps
5 Beeps
6 Beeps
Over Voltage
Under Voltage
Retraction or Dogging
failure
Push to Set
> 28V unit will shut down. Check voltage & adjust to 24 V.
< 22V unit will shut down. Check voltage & adjust to 24 V.
Device physically binding during retraction or pulled from the dogged position.
Device is recording it’s new position and power mode after the 6th beep.
4 Beeps
Failed Sensor
Verify all 3 sensor wires are installed correctly. Replace sensor if problem
persists by contacting oce.
1. After 1
st
fail: 5 beeps then immediately attempts to retract again.
2. After 2
nd
fail: 5 beeps with pause in-between for 30 seconds then
device attempts to retract again.
3. After 3
rd
fail: 5 beeps every 7 minutes, device will not attempt to retract.
To Reset: Depress bar for 5 seconds at any time.
Ceiling Tile
Legend
Standard Placement
Optional Placement
Module
GREEN
CHANNEL 1
LED
NORMALLY OPEN
DRY CONTACT FROM
ACCESS CONTROL
SYSTEM
NO VOLTAGE
LOCKING
HARDWARE
+
-
CAT
Recommended Power Supplies:
All Command Access exit devices & field installable kits have been thoroughly
cycle tested with Command Access power supplies at our factory.
For more information, visit our website
el ecT rifi ed exi T devic e
InstallatIon Exam p l E
US CUSTOMER SUPPORT1-888-622-2377 | WWW.COMMANDACCESS.COM | CA CUSTOMER SUPPORT 1-855-823-3002
in s Ta l l aT i o n in s T r u c T i o n s
US CUSTOMER SUPPORT1-888-622-2377 | WWW.COMMANDACCESS.COM | CA CUSTOMER SUPPORT 1-855-823-3002
Note: For AHT4/5 & PD11’s purchased after 2015 only.
Remove (2) screws securing the push pad
end caps on the front & back, and then the
push pad end caps. Place all to the side
1.
Remove Dogging Assembly by removing (2)
screws furthest to the back end of the device.
3.
Remove (4) screws securing baserail to
housing, then slide baserail out of device.
2.
Visually conrm what side the donut bumper is on.
If it is on the left side the correct position,skip next
two steps. If it’s on the right side or if you need to
make any cuts to the back activiting bracket follow the
next steps. Both require removal of the back activing
bracket.
4.
1
2
Remove (2) screws to release the back activating
bracket. Pull up on bracket and remove bottom pin
from activiting bracket (step 6).
5.
1
2
Correct
Front of Device
Back of Device
Change the donut bumper to the correct side (left side
when looking from the back) and re-install the pin. You’ll
need to line up the donut hole (now I’m hungry) with the
activing bracket holes and push the pin thru.
6.
in s Ta l l aT i o n in s T r u c T i o n s
US CUSTOMER SUPPORT1-888-622-2377 | WWW.COMMANDACCESS.COM | CA CUSTOMER SUPPORT 1-855-823-3002
9.
Drop the attaching hook on the motor
assembly onto the botton pin of the
activiting bracket.
Now with the donut bumper is on the correct
side re-install both screws to secure the
activating bracket back to the baserail
7.
Depress the back activating bracket for
easy access to the bottom pin.
8.
11.
Line up the motor’s mounting bracket screw
holes with the existing screw holes from the
dogging assembly on the exit device housing.
Cut down
Good!
3/4
Cut
Back Activing Bracket will need to be cutdown if it has a dogging hook like pictured below.
1
2
1
2
11.
Secure the motor assemby from the back of the device with (2) of the nished
screws provided.
1
2
1
2
in s Ta l l aT i o n in s T r u c T i o n s
US CUSTOMER SUPPORT1-888-622-2377 | WWW.COMMANDACCESS.COM | CA CUSTOMER SUPPORT 1-855-823-3002
Install (2) screws provided based
on nish of your device to secure
motor to exit device housing.
Re-install top pins on both activing brackets
and slide on the push pad making sure pins
are in the proper channel.
Re-install (2) screws securing the push
pad end caps on the front & back.
12.
14.
13.
15. Set the “Push to Set Adjustment” following the
steps below.
MM4 Switches
ON
ON
OFF
STANDARDTORQUE
HIGH TORQUE
PTS Programing Lock
PTS PROGRAMING On
OFF
1
2
Select your preferred torque mode (ships in standard torque) Press the device push pad
to the desired setting. (Recommend to fully depress and release 5%, giving the device
room for changing door conditions.)
Step 2- While depressing the push pad, apply power. (i.e. presenting the credential to the reader).
Step 3- Continue to keep pad depressed, the device will beep 6 times. After the beeps have stopped,
release the pad and now the adjustment is complete. If not to your liking repeat the 3 steps.
Step 4- Once you found the correct location, turn PTS switch to OFF position.
Setting PTS
**Important Info**
Make sure to set PTS before nishing installation
Step 1-
1
2
/