  • Hello! I am an AI chatbot trained to assist you with the HYDAC FILTER SYSTEMS OFU Filtromat Operating And Maintenance Instructions Manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
OFU
Filtromat
Operating and Maintenance Instructions
English • (translation of original instructions)
Document No. : 3120755d • 10/24/2019
Follow these instructions for proper and safe use.
Keep for future reference.
Table of Contents HYDAC FILTER SYSTEMS GMBH
ii BeWa OFU 3120755d en-us lq
Table of Contents
1 General ..................................................................................................................... 5
1.1 Imprint .............................................................................................................. 5
1.2 Documentation Representative........................................................................ 5
1.3 Purpose of this manual .................................................................................... 6
1.4 Target group of the manual.............................................................................. 6
1.5 Illustrations in the manual ................................................................................ 7
1.5.1 Illustration on the title page.................................................................. 7
1.5.2 Representation of requirements .......................................................... 8
1.5.3 Representation of procedural instructions ........................................... 8
1.5.4 Representation of intermediate results/results .................................... 9
1.5.5 Representation of warning/general safety information ...................... 10
1.5.6 Signal words and their meaning in the general safety information .... 11
1.6 Hazard symbols / pictograms......................................................................... 12
1.7 Supplementary symbols................................................................................. 13
1.8 Exclusion of liability/warranty ......................................................................... 14
1.9 Notes on copyright ......................................................................................... 14
1.10 Validity of this manual .................................................................................... 15
2 Safety information ................................................................................................... 16
2.1 Fire-fighting / extinguishing a fire ................................................................... 17
2.2 Stoppage in an emergency (EMERGENCY STOP)....................................... 18
2.3 Observing regulatory information ................................................................... 18
2.4 Wear suitable clothing.................................................................................... 18
3 Overview of the filtration unit................................................................................... 19
3.1 Proper/designated use ................................................................................... 20
3.2 Improper use or use deviating from intended use.......................................... 21
3.3 Checking the scope of delivery ...................................................................... 22
3.4 Dimensions .................................................................................................... 24
3.4.1 OFU - Dimensions ............................................................................. 25
3.5 Hydraulic diagram .......................................................................................... 26
HYDAC FILTER SYSTEMS GMBH Table of Contents
BeWa OFU 3120755d en-us lq iii
3.6 Decoding the name plate ............................................................................... 26
3.6.1 Model code ........................................................................................ 28
3.7 Requirements of the workplace & working environment ................................ 29
3.8 Components / Operating elements ................................................................ 30
4 Transporting/storing the filter unit............................................................................ 32
5 Setting up / assembly / integration of the filter unit ................................................. 33
5.1 Avoiding siphoning ......................................................................................... 34
5.2 Measure or display dynamic pressure / differential pressure......................... 35
5.3 Avoiding the mixing of oils - Emptying the filter unit....................................... 36
5.4 Making the electrical connections .................................................................. 37
5.4.1 Connecting the filter unit with a three-phase electric motor............... 37
5.5 Connecting the suction/pressure port ............................................................ 38
5.6 Attaching / connecting the suction / pressure hoses (Accessories) ............... 40
5.7 Inserting the filter element.............................................................................. 41
5.8 Commissioning............................................................................................... 41
6 Operation ................................................................................................................ 43
6.1 Activating the main switch.............................................................................. 44
6.2 Observing the optical clogging indicator (optional) ........................................ 45
7 Performing maintenance ......................................................................................... 46
7.1 Maintenance table.......................................................................................... 46
7.2 Changing the filter element ............................................................................ 46
7.3 Checking/cleaning the strainer....................................................................... 50
8 Decommissioning / Disposal ................................................................................... 52
9 Appendix ................................................................................................................. 53
9.1 EC declaration of conformity .......................................................................... 53
9.2 Locating spare parts....................................................................................... 53
9.2.1 Order filter elements .......................................................................... 54
9.2.1.1 Filter elements - size 1300........................................................ 54
9.2.1.2 Filter elements - size 2600........................................................ 55
Table of Contents HYDAC FILTER SYSTEMS GMBH
iv BeWa OFU 3120755d en-us lq
9.3 Clogging indicators - technical data ............................................................... 56
9.3.1 Differential pressure indicator, visual – VMxB.x .............................. 56
9.3.2 Differential pressure indicator, visual – VMxBM.x ........................... 58
9.3.3 Differential pressure gauge, electric (VM x C.x) ................................ 60
9.3.4 Differential pressure gauge, electric (VM x D.x /-L-xx) ...................... 62
9.4 Finding a Customer Service team.................................................................. 64
Glossary .................................................................................................................. 67
Index ....................................................................................................................... 68
HYDAC FILTER SYSTEMS GMBH General | 1
BeWa OFU 3120755d en-us lq 5 / 72
1 General
In this chapter, you will find helpful notes on handling these in-
structions.
1.1 Imprint
Manufacturer / publisher and responsible for the content:
Address of the manufacturer Contact address
HYDAC FILTER SYSTEMS
GMBH
Industriegebiet
66280 Sulzbach / Saar
HYDAC FILTER SYSTEMS
GMBH
Justus-von-Liebig-Str., Werk
20
66280 Sulzbach / Saar
Germany Germany
Homepage: www.hydac.com
Court of Registration: Saarbrücken , HRB 17216
Executive directors: Mathias Dieter ,
Dipl.Kfm. Wolfgang Haering
Tab.1:
Impressum
1.2 Documentation Representative
The contact data of the person authorized with the documenta-
tion is:
Mr. Günter Harge
c/o HYDAC International GmbH, Industriegebiet, 66280
Sulzbach / Saar
Germany
Phone: +49 6897 509 1511
Fax: +49 6897 509 1394
Tab.2:
Documentation Representative
1 | General HYDAC FILTER SYSTEMS GMBH
6 / 72 BeWa OFU 3120755d en-us lq
1.3 Purpose of this manual
Before you use this product for the first time or if you have
been asked to carry out other work on the product, please read
this manual.
The use and the handling of the product described in the fol-
lowing, as well as its use, are not self-explanatory and are de-
scribed in detail in this manual and the associated technical
documentation.
This manual will help you to use the product as intended, prop-
erly, effectively, and safely. Therefore, you are requested to
read the following chapters attentively and carefully. Please re-
fer to it every time you require decisive details.
This manual informs and warns you of risks, against which the
risk reduction through the design and protective measures may
not be effective or not fully effective.
1.4 Target group of the manual
This manual was created for the following target group.
Target group Tasks
Owner This manual and the associated docu-
ments must be kept accessible at the in-
stallation location of the product and also
for later use.
Ask the employees to read and follow the
manual and the associated documents, in
particular, the safety and warning instruc-
tions.
Observe the additional product-related in-
structions and requirements.
Specialist person-
nel
Read, observe and follow this manual and
the associated documents, in particular,
the safety and warning instructions.
Tab.3:
Target group
HYDAC FILTER SYSTEMS GMBH General | 1
BeWa OFU 3120755d en-us lq 7 / 72
1.5 Illustrations in the manual
You will find illustrations in this manual. You can find details re-
garding these in the following chapters.
1.5.1 Illustration on the title page
You will find the following information on the title page of this
manual:
Short name of the product
Product name
Operating and Maintenance Instructions
12345678 ● ##.##.####
English (translation of original instructions)
Valid from:
- from s/no.
- ... ...
- ... ...
1
5
2
4
3
Fig.1:
Overview / labeling of the title page
1 Short name of the product / product name
2 Type of document
3 Language
4 Document no./Index ● Date of printing
5 Supplementary instructions regarding the validity of the
manual (optional)
Please note that you can directly access information through
the directories. However, this does not release you from the
obligation to read this manual fully before commissioning.
1 | General HYDAC FILTER SYSTEMS GMBH
8 / 72 BeWa OFU 3120755d en-us lq
The document no. with the index (4) is meant for identifying
and reordering the manual. The index is incremented every
time the manual is revised or changed.
The manual contains a table of contents, a list of tables and
figures, an index and a glossary.
1.5.2 Representation of requirements
These are absolutely required for carrying out a work activity
on the product and are marked with a check mark and are in
bold in the text.
An example for the representation of requirements:
ühe product is assembled and connected.
üThe product is switched off.
1. Switch the product on.
1.5.3 Representation of procedural instructions
In the case of procedural instructions, there are the two follow-
ing representations:
Procedural instructions with a fixed sequence
Procedural instructions, whose sequence must be complied
with without fail are listed with sequential numbering (1., 2., 3.,
etc.).
An example for procedural instructions with a fixed sequence:
1. Remove the transport securing device.
2. First fill the product.
3. Switch the product on.
Procedural instructions with a random sequence
Procedural instructions that have a random sequence are
listed as bullet points (-).
HYDAC FILTER SYSTEMS GMBH General | 1
BeWa OFU 3120755d en-us lq 9 / 72
An example of a procedural instruction with a random se-
quence:
Clean the display.
Rinse the product.
1.5.4 Representation of intermediate results/results
In the case of some activities, it is necessary to carry out work
steps with intermediate results and end results.
Intermediate results are the consequence of activities; they are
marked with an indented arrow.
End results represent the end of an activity and are repre-
sented with a flag.
An example for a procedural instruction with intermediate re-
sult and final result:
1. Switch the product on.
ðThe display lights up.
2. Press the button.
OThe product is now ready for use.
1 | General HYDAC FILTER SYSTEMS GMBH
10 / 72 BeWa OFU 3120755d en-us lq
1.5.5 Representation of warning/general safety
information
All the warning / general safety information in this manual are
highlighted with pictograms and signal words. The pictogram
and the signal word give you an indication of the severity of the
danger.
Warning / general safety information, which are placed ahead
of each activity, are represented as follows:
CAUTION
Type and source of danger
Hazard symbol
Consequence of the danger
Measures to avert danger
HYDAC FILTER SYSTEMS GMBH General | 1
BeWa OFU 3120755d en-us lq 11 / 72
1.5.6 Signal words and their meaning in the general
safety information
In these instructions you will find the following signal words:
DANGER
DANGER – The signal word indicates a hazardous situation
with a high level of risk, which, if not avoided, will result lethal
or serious injury.
WARNING
WARNING – The signal word indicates a hazardous situation
with a medium level of risk, which, if not avoided, can result
lethal or serious injury.
CAUTION
CAUTION – The signal word indicates a hazardous situation
with a low level of risk, which, if not avoided, can result in mi-
nor or moderate injury.
NOTICE
NOTICE – The signal word indicates a hazardous situation
with a high level of risk, which, if not avoided, will result in
damage to property.
1 | General HYDAC FILTER SYSTEMS GMBH
12 / 72 BeWa OFU 3120755d en-us lq
1.6 Hazard symbols / pictograms
The following are the safety symbols / pictograms in this man-
ual. They indicate specific dangers to persons, property or to
the environment. Observe these safety symbols / pictograms
and act with particular caution in such cases. Always keep all
symbols / pictograms intact and legible.
Warning signs used
These signs are listed for all general safety information and in-
structions in these operating instructions which indicate partic-
ular dangers to persons, property or the environment.
Danger point warning
Dangerous electrical voltage warning
Mandatory action symbols used
These symbols are listed for all general safety information and
instructions in these operating instructions that refer to particu-
lar dangers to persons, property or the environment.
Follow the instructions.
Other symbols used
These signs are listed for the general safety instructions in
these operating instructions, for example, which indicate a par-
ticular danger to persons, property or the environment.
HYDAC FILTER SYSTEMS GMBH General | 1
BeWa OFU 3120755d en-us lq 13 / 72
Exposed electrical components
Danger due to operating pressure
Signs used for the required specialist personnel
These symbols show the required training/knowledge for in-
stallation work and/or maintenance work.
Specialist personnel - Electrician
Such persons have specific specialist training
and several years' work experience. They are
able to assess and perform the work assigned to
them, they are also able to recognize potential
dangers.
Specialist personnel - Mechanic
Such persons have specific specialist training
and several years' work experience. They are
able to assess and perform the work assigned to
them and they are also able to recognize poten-
tial dangers.
1.7 Supplementary symbols
You will find the following symbols in the manual as additional
details:
Tip for handling the product
1 | General HYDAC FILTER SYSTEMS GMBH
14 / 72 BeWa OFU 3120755d en-us lq
Required tools
1.8 Exclusion of liability/warranty
For the warranty provided by us, please refer to the Terms of
Delivery. They are made available to you at the conclusion of
the contract at the latest. You will also find these under
www.hydac.com -> General Terms and Conditions (T&C).
This manual was prepared to the best of our knowledge. Nev-
ertheless and despite the greatest care, it cannot be excluded
that mistakes could have crept in. Therefore, please under-
stand that, in the absence of any provisions to the contrary
hereinafter, our warranty and liability – for any legal reasons
whatsoever – are excluded in respect of the information in this
manual. In particular, we shall not be liable for lost profit or
other financial loss.
This exclusion of liability does not apply in cases of intent and
gross negligence. Moreover, it does not apply to defects which
have been deceitfully concealed or whose absence has been
guaranteed, nor in cases of culpable harm to life, physical in-
jury and damage to health. If we negligently breach any mate-
rial contractual obligation, our liability shall be limited to fore-
seeable damage. Claims due to the Product Liability shall re-
main unaffected.
1.9 Notes on copyright
All copyrights for this manual lies with the manufacturer. No
part of this manual may be reproduced in any form or pro-
cessed, duplicated or distributed using electronic systems with-
out the written consent of the manufacturer. Any infringements
of the above shall be liable to damage compensation.
HYDAC FILTER SYSTEMS GMBH General | 1
BeWa OFU 3120755d en-us lq 15 / 72
1.10 Validity of this manual
The diagrams and visualizations in this manual are meant for
general illustration purposes. Therefore, representations and
functional options can deviate from the delivered product.
We reserve the right to changes to the contents of this manual
without prior notice.
2 | Safety information HYDAC FILTER SYSTEMS GMBH
16 / 72 BeWa OFU 3120755d en-us lq
2 Safety information
DANGER
Danger due to unintended use
Bodily injury / Damage to property
uNever operate the filter unit in potentially explosive atmos-
pheres.
uThe filter unit is to be used only with the permissible oper-
ating media.
NOTICE
Impermissible operating media
The filter unit will be damaged.
uUse the filter unit only with mineral oils and mineral oil
based-raffinates.
HYDAC FILTER SYSTEMS GMBH Safety information | 2
BeWa OFU 3120755d en-us lq 17 / 72
The General Safety Information provides important information
on handling the device. A prerequisite for safe work is the
maintenance of all stated General Safety Instructions and pre-
cautions. In addition, the local accident prevention specifica-
tions and general safety regulations that apply for the area of
operation of the device must be observed.
2.1 Fire-fighting / extinguishing a fire
Use a powder extinguisher that corresponds to fire class B as
per EN2 to extinguish any fires / to fight fires.
Fig.2:
Fire protection
class B
Maintain a minimum safe distance from electrical components.
For a mains voltage of up to 1000V, the minimum safe dis-
tance is 1m.
Fig.3:
Minimum distance for fire fighting
2 | Safety information HYDAC FILTER SYSTEMS GMBH
18 / 72 BeWa OFU 3120755d en-us lq
2.2 Stoppage in an emergency (EMERGENCY STOP)
Disconnect the product from all sources of energy in an emer-
gency.
2.3 Observing regulatory information
Observe the following regulatory information and directives:
Legal and local regulations for accident prevention
Legal and local regulations for environmental protection
Country-specific regulations, organization-specific regula-
tions
2.4 Wear suitable clothing
Loose-fitting clothing increases the danger of being caught or
being drawn in on rotating parts, and the risk of getting caught
on protruding parts. You can be severely injured or killed in
these cases.
Wear closely fitting clothing.
Do not wear any rings, chains or any other jewelry.
Wear a hair net if you have long hair.
Wear work safety shoes.
HYDAC FILTER SYSTEMS GMBH Overview of the filtration unit | 3
BeWa OFU 3120755d en-us lq 19 / 72
3 Overview of the filtration unit
3 | Overview of the filtration unit HYDAC FILTER SYSTEMS GMBH
20 / 72 BeWa OFU 3120755d en-us lq
3.1 Proper/designated use
Use the filter unit only for the application described in the fol-
lowing.
The filter unit is used in combination with the permitted filter el-
ements (identification -KB) to clean / filter hydraulic and lubri-
cating oils in the bypass flow or to fill the hydraulic systems, to
transfer as well as drain the hydraulic tanks.
Intended use of the product also extends to the following:
Observing all instructions in the instruction manual.
Complying with inspection and maintenance work.
Claims for defects or liability, regardless of the legal founda-
tion, do not apply with incorrect or improper installation, com-
missioning, usage, handling, storage, maintenance, repair, use
of unsuitable components or other circumstances for which the
manufacturer is not responsible.
The manufacturer assumes no responsibility for determining
the interfaces for installation in a system or the installation, use
or functionality of the product in this system.
/