  • I've reviewed the installation instructions for the Lithonia Lighting DA12WB and DAD12WB light fixtures, focusing on key safety steps, mounting procedures, and adjustment capabilities. The document details the importance of proper grounding and de-energizing equipment before servicing, and provides steps for installing the mounting arm and adjusting the fixture for uptilt. I'm ready to answer your questions about these fixtures.
  • What should be done before installing, servicing, or maintaining the equipment?
    What is the minimum size of the fastener to secure the mounting plate?
    What is the purpose of the gasketing material?
Lithonia Lighting Outdoor
One Lithonia Way, Conyers, GA 30012
Phone: 800-279-8041 Fax: 770-918-1209
www.lithonia.com Part Number: RJ5206801 Rev C
Revision Date: 10-14-08
Installation Instructions
DA12WB & DAD12WB
SAVE THESE INSTRUCTIONS
WARNING
To reduce the risk of death, injury or property damage from fire, electric shock, cuts,
abrasions, falling parts, and other hazards:
Service of the equipment must be performed by qualified service personnel.
Installation and maintenance must be performed by a person familiar with the construction and
operation of this product and any hazards involved. All applicable codes and ordinances must
be followed.
Read this document before installing, servicing, or maintaining this equipment or installing a
lamp. These instructions do not cover all installation, service, and maintenance situations. If
your situation is not covered, or if you do not understand these instructions or additional
information is required, contact Lithonia Lighting or your local Lithonia LIghting Distributor.
Read and follow all warnings and instructions provided by the lamp manufacturer.
WARNING
Before installing, servicing, or maintaining this equipment, follow these general precautions.
To reduce the risk of electrocution:
Make sure the equipment is properly grounded.
Always de-energize the circuit and/or equipment before connecting to, disconnecting
from, or servicing the equipment.
To reduce the risk of fire:
Keep material away that can burn from hot lamp.
Make sure lamps are correctly installed.
Use supply conductors with a minimum installation temperature rating as specified on
equipment.
To reduce the risk of personal injury from cuts, abrasions, or falling parts:
Wear gloves to prevent cuts or abrasions from sharp edges when removing from
carton, handling and maintaining this equipment.
Do not use abrasive materials, glass cleaners or other solvents on reflector or lens.
These substances may damage equipment and cause parts to eventually break and
fall.
Do not install a damaged fixture.
CAUTION: Observe lamp manufacturer’s recommendations and restrictions on lamp operation,
including but not limited to ballast type, burning position, replacement and cycling. Use only lamps that
comply with applicable ANSI standards.
NOTICE: If lamp is marked it contains mercury. Follow disposal laws. See
www.lamprecycle.org
Lithonia Lighting, a division of Acuity Brands Lighting, Inc., assumes no responsibility for claims arising out of
improper or careless installation or handling of this product.
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
DISCONTINUED
Lithonia Lighting Outdoor
One Lithonia Way, Conyers, GA 30012
Phone: 800-279-8041 Fax: 770-918-1209
www.lithonia.com Part Number: RJ5206801 Rev C
Revision Date: 10-14-08
Installation Instructions
DA12WB & DAD12WB
1. Using Lithonia Lighting Mounting Plate Drilling Template #6, secure plate to wall. Add weather proof caulking or sealant
between mounting plate and wall to ensure weather tight integrity. The hole size will be determined by the fastener (supplied by
others). The minimum fastener size is 1/2" diameter and the maximum fastener size is 5/8" diameter. Align one end of the
mounting arm to wall mounting plate, remembering to insert the gasketing material (furnished) between the arm and mounting
plate. Insert the two (2) 7/16" x 1-3/4" attachment bolts and lock washer through the arm and gasket until they engage the wall
mounting plate. Tighten both bolts securely.
2. To mount fixture, align gasket to mounting holes between the fixture housing and mounting bracket. Insert two (2) 7/16" x
1-3/4" attachment bolts through mounting arm and into housing, being careful to align gasketing between fixture housing
and mounting arm. Install 7/16" split lock washer and hex jam nuts on the bolts inside fixture housing and tighten securely.
Check to assure fixture is level and plum.
3. To adjust mounting arm, remove both center hole plugs located at arm's pivot point. Loosen the single bolt and nut
assembly, being careful not to allow fixture housing to drop. Set the mounting arm at desired angle of uptilt and tighten the
center nut and bolt assembly securely. (This mounting arm has raised degree scales located on the top and bottom sides of
arm, divided into 5o increments) Install both hole plugs to complete installation.
WARNING: Options are to be installed in the field. Be sure the electrical components are not energized during mainte-
nance or installation of product. DO NOT alter fittings when mounting the fixtures. Recheck all connections and bolts to
insure they will not loosen due to vibration.
Mounting Plate Detail
DA12WB Assembly: Note this drawing is not to scale and should
be used for dimensional purposes only.
Note: DAD12WB degree arm
shown at right will have rounded
edges to match KAD Contour
Series look. Assembly will be the
same as DA12WB above.
DISCONTINUED
/