Golmar TRIP TSU3-PLUS ML REV.0116 Owner's manual

Category
Video switches
Type
Owner's manual

This manual is also suitable for

TSU3-PLUS ML rev.0116
SU3-PLUS
Switch Unit
Instructions manual
Cód. 50121848
2
INTRODUCTION
STARTING RECOMMENDATIONS
INDEX
First of all we would like to thank and congratulate you for the purchase of this product manufactured by
Golmar.
The commitment to reach the satisfaction of our customers is stated through the ISO-9001 certification
and for the manufacturing of products like this one.
Its advanced technology and exacting quality control will do that customers and users enjoy with the
legion of features this system offers To obtain the maximum profit of these features and a properly wired.
installation, we kindly recommend you to expend a few minutes of your time to read this manual.
The installation and handling of this equipment must be performed by authorised personnel.
Install or modify the equipment without the power connected.
Do not use excessive force when tightening the switch unit connection block screws.
The entire installation must be at least away from any .40 cm. other installation
Before connecting the system, check the connections between door panel, SU3-PLUS switch unit,
distributors, monitors, telephones and the power supply connection.
When starting the equipment for the first time, or after a modification, the system will remain inactive
for around 30 seconds due to the initial busy channel time.
Do always follow the enclosed information.
Introduction........................................................................................................................2
Index .................................................................................................................................2
Starting recommendations ...................................................................................................2
Safety precautions...............................................................................................................3
System characteristics ..........................................................................................................3
Operation modes .............................................................................................................4-9
Description.......................................................................................................................10
Installation .......................................................................................................................10
Configuration dip switch.....................................................................................................11
Input status Led..................................................................................................................11
Installation diagrams..........................................................................................................12
Video installation with coaxial cable and 1 switch unit ....................................................12-13
Video installation without coaxial cable and 1 switch unit ................................................14-15
Video installation with coaxial cable and 2 switch units ...................................................16-17
Video installation without coaxial cable and 2 switch units ..............................................18-19
3
SYSTEM CHARACTERISTICS
SAFETY PRECAUTIONS
Install or modify the equipment .without the power connected
The installation and handling of these equipments must be performed by .authorised personnel
The entire installation must be at least away from any .40 cm. other installation
Do not use excessive force when tightening the connector screws.
Install the switch unit in a dry and protected place without risk of drip or water projections.
Avoid to place it near to heating sources, dusty locations or humid enviroments.
Do not block ventilation holes of the switch unit so that air can circulate freely.
To avoid damage, the switch unit has to be firmly fixed.
Switch unit for the video door panel system (with "+H" output).Plus / Uno
Up to 3 doors panels per switch unit.
Up to 2 doors panels per switch unit in daisy chain.
Unlimited number of switch unit in daisy chain.
No connect any element between the door panel and the switch unit.
Distribu , monitors, tel ,tors ephones porter's exchanges and digital repeater will be connected to the
output of the switching unit.
Maximum distance between the door panel and switch unit: 300m.
Maximum distance between power supply and switch unit: 3m., installwith a wire section of 1.5 mm (
in the same cabinet).
Switch unit needs a power supply (FA-Plus/C or FA-Plus).
Door panels need FA-Plus/C power supply with:
External lock release push button.
EL502 dc/ac converter module to connect a.c lock release (only Stadio door panel).
Configuration dip switch (for systems with general door panels).
Status led for each input to indicate if it is connected to monitor Bus.
2
4
OPERATION MODES
2
Plus porter's
exchange
Tekna PLUS monitors
6
MONITORS / PORTER'S EXCHANGE
ancel
?
!
.
-
,
abc2 def3
jkl5
mno6
pqrs7 tuv8 wxyz9
+-0x*
ghi4
6
6
6
6
2
FA PLUS/C-
M
2
Lock release
Vd.c
S
2
S
INPUT 1 INPUT 2
OUTPUT
Al.
SU3-PLUS
6
2
DOOR PANELS
Plus door panel
5
M =Master.
S =Slave.
M M
M M
INPUT 3
-
+/
7 7 7
PLUS SYSTEM
Video installation with 1 switch unit (door panels without power supplies).
Permits the installation up to 3 video door panels ( system) directly to the switch unit simplifyingPlus/Uno
wiring between door panels.
Remember: tors ephones porter's exchanges and digital repeater will beDistribu , monitors, tel ,
connected to the output of the switch unit, never between door panel and switch unit.
See installation diagrams pages 31 to 34.
Continue
*
( ) Door panel without power supply needs 7 wires (to connect the '+' terminal).
*
( ) *
( ) *
( )
Plus door panel Plus door panel
Lock release
Vd.c
Lock release
Vd.c
FA PLUS/C or FA-PLUS-
5OPERATION MODES
Coming from previous page
2
FA PLUS/C-
2
FA PLUS/C-
2
FA PLUS/C-
Video installation with 1 switch unit (door panels with power supplies).
Permits the installation up to 3 video door panels ( system) directly to the switch unitPlus/Uno
simplifying wiring between door panels.
Important:Will be necessary to connect a power supply on the door panels with "AP" function and/or
EL502 dc/ac converter module to connect a.c lock release (only Stadio door panel).
Do not connect the positive terminal of the door panel (with power supply) to the switch unit.
Remember: tors ephones porter's exchanges and digital repeater will beDistribu , monitors, tel ,
connected to the output of the switch unit, never between door panel and switch unit.
See installation diagrams pages 31 to 34.
( )
*
Continue
( )
*AP
2
( )
*AP
2
( )
*AP
2
( )
*( )
*( )
*
2
Plus porter's
exchange
Tekna PLUS monitors
6
MONITORS / PORTER'S EXCHANGE
ancel
?
!
.
-
,
abc2 def3
jkl5
mno6
pqrs7 tuv8 wxyz9
+-0x*
ghi4
6
6
6
6
2
FA PLUS/C-
M
2
Lock release
Vd.c
S
2
S
INPUT 1 INPUT 2
OUTPUT
Al.
SU3-PLUS
6
2
DOOR PANELS
Plus door panel
5
M =Master.
S =Slave.
M M
M M
INPUT 3
-
+/
6 6 6
PLUS SYSTEM
Plus door panel Plus door panel
Lock release
Vd.c
Lock release
Vd.c
FA PLUS/C or FA-PLUS-
Video installation with 2 switch units (door panels without power supplies).
Permits the installation up to 5 video door panels ( system) directly to the switch unit simplifyingPlus/Uno
wiring between door panels. The 2nd switch unit permits the installation up to 2 video door panels
( system . If the system has more than two switch units, wire them as the second is connected;Plus/Uno )
connecting the output of the previous switch unit to the input of the next switch unit. In the last unit will
connect the monitor Bus.
Remember: D tors ephones porter's exchanges and digital repeater will beistribu , monitors, tel ,
connected to the output of the switch unit, never between door panel and switch unit.
See installation diagrams pages 35 to 38.
Coming from previous page
6
6
OPERATION MODES
2
M
2
Lock release
Vd.c
S
2
S
INPUT 1 INPUT 2
OUTPUT
Al.
SU3-PLUS
2
FA PLUS/C-
DOOR PANELS
Plus door panel
INPUT 3
-
+/
7 7 7
PLUS SYSTEM
*
( ) Door panel without power supply needs 7 wires (to connect the '+' terminal).
*
( ) *
( ) *
( )
Plus door panel Plus door panel
Lock release
Vd.c
Lock release
Vd.c
M =Master.
S =Slave.
6
ancel
?
!
.
-
,
abc2 def3
jkl5
mno6
pqrs7 tuv8 wxyz9
+-0x*
ghi4
2
FA PLUS/C-
6
5
7
Continue
MONITORS / PORTER'S EXCHANGE
2
Lock release
Vd.c
S
2
S
INPUT 1 INPUT 2
OUTPUT
Al.
SU3-PLUS
2
DOOR PANELS
INPUT 3
-
+/
6 7 7
*
( ) *
( )
Plus door panel Plus door panel
Lock release
Vd.c
Plus porter's
exchange
Tekna PLUS monitors
6
6
6
6
M M
M M
FA PLUS/C or FA-PLUS-
8
OPERATION MODES
Coming from previous page
6
INPUT 1 INPUT 2
OUTPUT
Al.
SU3-PLUS
2
FA PLUS/C-
INPUT 3
-
+/
PLUS SYSTEM
M =Master.
S =Slave.
DOOR PANELS
2
FA PLUS/C-
2
FA PLUS/C-
2
FA PLUS/C-
( )
*AP
2
( )
*AP
2
( )
*AP
2
( )
*( )
*( )
*
2
M
2
Lock release
Vd.c
S
2
S
Plus door panel
6 6 6
Plus door panel Plus door panel
Lock release
Vd.c
Lock release
Vd.c
Video installation with 2 switch units (door panels with power supplies).
Permits the installation up to 5 video door panels ( system) directly to the switch unitPlus/Uno
simplifying wiring between door panels. The 2nd switch unit permits the installation up to 2 video door
panels ( system . If the system has more than two switch units, wire them as the second isPlus/Uno )
connected; connecting the output of the previous switch unit to the input of the next switch unit. In the
last unit will connect the monitor Bus.
Important:Will be necessary to connect a power supply on the door panels with "AP" function and/or
EL502 dc/ac converter module to connect a.c lock release (only Stadio door panel).
Do not connect the positive terminal of the door panel (with power supply) to the switch unit.
Remember: tors ephones porter's exchanges and digital repeater will beDistribu , monitors, tel ,
connected to the output of the switch unit, never between door panel and switch unit.
See installation diagrams pages 35 to 38.
( )
*
9
6
ancel
?
!
.
-
,
abc2 def3
jkl5
mno6
pqrs7 tuv8 wxyz9
+-0x*
ghi4
2
FA PLUS/C-
6
5
MONITORS / PORTER'S EXCHANGE
INPUT 1 INPUT 2
OUTPUT
Al.
SU3-PLUS
2
FA PLUS/C or FA-PLUS-
DOOR PANELS
INPUT 3
-
+/
6
Plus porter's
exchange
Tekna PLUS monitors
6
6
6
6
M M
M M
2
FA PLUS/C-
2
FA PLUS/C-
( )
*AP
2
( )
*AP
2
( )
*( )
*
2
Lock release
Vd.c
S
2
S
6 6
Plus door panel Plus door panel
Lock release
Vd.c
10
Detail of the switch unit installation.
The unit can be installed on a DIN guide
(6 elements), pressing it lightly.
To extract the unit from the DIN guide, use
a plain screwdriver to lever the flange as
shown in the picture.DIN 46277
3,5 x 50
DIN-7971
3,5 x 50
DIN-7971
Description of the SU3-Plus switch unit.
DESCRIPTION
INSTALLATION
Install the unit in a dry and protected place free from the risk of drip or water projections.
To avoid damage the unit must be firmly fixed.
Install or modify the equipment without the power
connected.
The installation and handling of this equipment must be
performed by authorised personnel.
To install the unit directly on the wall, drill two holes of
Ø6mm. and insert the wallplugs. Fix the unit with the
specified screws.
DIN rail latch release.
Configuration dip switch.
Connection block for access door panel 2.
Connection block for access door panel 3.
Label.
Power supply input.
Connection block for access door panel 1.
Riser connection block / next switch unit.
Input 3 status led.
Input 1 status led.
Input 2 status led.
Power supply LED.
11 CONFIGURATION
Description of the configuration dip switch.
Switches 1 and 2 to ON, there is no input connected to the Bus in standby
mode.
*Factory default
Switches 1 to ON and 2 to OFF, input 1 connects to the Bus in standby mode.
Description of input status led.
The switch unit has a status led for each input to indicate if it is
connected to monitor Bus.
Led verde Off: Input in standby mode, it is not connected to the
monitor Bus.
Blinking: The input is connected to monitor Bus (during
call reception, communication, autoswitch-on,
etc. progresses).
12
12
12
12
Switches 1 to OFF and 2 to ON, input 2 connects to the Bus in standby mode.
Switches 1 and 2 to OFF, input 3 connects to the Bus in standby mode.
Led verde
Fixed: Input is connected to monitor Bus in standby mode
(see t ).he configuration dip switchSW1
The configuration dip switch is located on the upper part ofSW1
the module.
Configuration dip switch for systems with general door panels.Important:
(Contact our technical support department).
INPUT STATUS LED
12
INSTALLATION DIAGRAMS
Lock release
Vd.c.
SW2
M
DMalla
Vin-AinAout Vin+ Vout-Vout+
CN2
+
-
+CV1CV2
-
10
1
9
2
8
3
7
4
6
5
CN5
SW1
DVi- Vi+
INPUT 1
-
+
-
+HAin +DVi- Vi+
-
+HAin +
INPUT 218Vdc
DVi- Vi+
INPUT 3
-
+HAin + D VpoMpo
-
+HAo+
OUTPUT
SEC
PRI
230
Main
110 0
--
++
Access door panel
SU3-PLUS
Take off JP1 jumper
of all the distributors
except in the last one.
A
_
+D
Malla
Vin Vout
CN4
A
_
+D
Malla
Vin Vout
CN4
ED 1 D2
+
D4L-PLUS
JP1
S
Next distributor
IMPORTANT:For the configuration and programming of each equipment, see the corresponding manual.
( )
*
FA-Plus/C
rev.938072
SEC
PRI
230
Main
110 0
--
++
AP
( )
*
To access door panel S
FA-Plus/C or FA-Plus
(1)
(1)
13
Access door panel
Lock release
Vd.c.
SW2
S
DMalla
Vin-AinAout Vin+ Vout-Vout+
CN2
+
-
+CV1CV2
-
10
1
9
2
8
3
7
4
6
5
CN5
SW1
Video installation with coaxial cable and 1 switch unit.
The installation diagram shows the connection of a video system with up to 3 door panels for the
same building. Master door panel with "AP" function, (external push button to exit from the
building).
Important:Will be necessary to connect a power supply on the door panels with "AP" function
and/or EL502 dc/ac converter module to connect a.c lock release (only Stadio door panel).
Do not connect the positive terminal of the door panel (with power supply) to the switch unit.
Remember: tors ephones porter's exchanges and digital repeater will beDistribu , monitors, tel ,
connected to the output of the switch unit, never between door panel and switch unit.
( )
*
M =Master.
S =Slave.
14
INSTALLATION DIAGRAMS
JP1
A
A
D
D
CT +
+
Vpi
Vd1
Mpi
Md1
_
_
A
D
CT
+
Vd6
Md6
_
A D+ Vpo Mpo
_
D6L-Plus/2H
VpMp
AD
_
+
EL562
JP1
VpMp
AD
_
+
EL562
JP1
SW2
DMalla
Vin-AinAout Vin+ Vout-Vout+
CN2
+
-
+CV1CV2
-
10
1
9
2
8
3
7
4
6
5
CN5
SW1
DVi- Vi+
-
+
-
+HAin +DVi- Vi+
-
+HAin +
18Vdc
DVi- Vi+
-
+HAin + D VpoMpo
-
+HAo+
FA-Plus/C or FA-Plus
SEC
PRI
230110 0
--
++
SU3-PLUS
( )
*
FA-Plus/C
rev.938072
SEC
PRI
230110 0
--
++
AP
( )
*
S
Lock release
Vd.c.
M
Main
Access door panel
Take off JP1 jumper
of all the distributors
except in the last one.
Next distributor
IMPORTANT:For the configuration and programming of each equipment, see the corresponding manual.
Main
To access door panel
(1)
(1)
INPUT 1 INPUT 2
INPUT 3 OUTPUT
15
SW2
S
DMalla
Vin-AinAout Vin+ Vout-Vout+
CN2
+
-
+CV1CV2
-
10
1
9
2
8
3
7
4
6
5
CN5
SW1
Access door panel
Video installation without coaxial cable and 1 switch unit.
The installation diagram shows the connection of a video system with up to 3 door panels for the same
building. Master door panel with "AP" function, (external push button to exit from the building).
Important:Will be necessary to connect a power supply on the door panels with "AP" function
and/or EL502 dc/ac converter module to connect a.c lock release (only Stadio door panel).
Do not connect the positive terminal of the door panel (with power supply) to the switch unit.
Remember: tors ephones porter's exchanges and digital repeater will beDistribu , monitors, tel ,
connected to the output of the switch unit, never between door panel and switch unit.
( )
*
M =Master.
S =Slave.
Lock release
Vd.c.
16
INSTALLATION DIAGRAMS
SW2
DMalla
Vin-AinAout Vin+ Vout-Vout+
CN2
+
-
+CV1CV2
-
10
1
9
2
8
3
7
4
6
5
CN5
SW1
Video installation with coaxial cable and 2 switch units.
The installation diagram shows the connection of a video system with up to 5 door panels for the same
building. Master door panel with "AP" function, (external push button to exit from the building).
If the system has more than two switch units, wire them as the second is connected; connecting the
output of the previous switch unit to the input of the next switch unit. In the last unit will connect the
monitor Bus.
Important:Will be necessary to connect a power supply on the door panels with "AP" function
and/or EL502 dc/ac converter module to connect a.c lock release (only Stadio door panel).
Do not connect the positive terminal of the door panel (with power supply) to the switch unit.
Remember: tors ephones porter's exchanges and digital repeater will beDistribu , monitors, tel ,
connected to the output of the switch unit, never between door panel and switch unit.
( )
*
DVi- Vi+
INPUT 1
-
+
-
+HAin +DVi- Vi+
-
+HAin +
INPUT 218Vdc
DVi- Vi+
INPUT 3
-
+HAin + D VpoMpo
-
+HAo+
OUTPUT
FA-Plus/C
rev.938072
SEC
PRI
230110 0
--
++
SU3-PLUS
To access door panel
To access door panel
S
S
Lock release
Vd.c.
S
Main
Access door panel
IMPORTANT:For the configuration and programming of each equipment, see the corresponding manual.
M =Master.
S =Slave.
17
SW2
DMalla
Vin-AinAout Vin+ Vout-Vout+
CN2
+
-
+CV1CV2
-
10
1
9
2
8
3
7
4
6
5
CN5
SW1
DVi- Vi+
INPUT 1
-
+
-
+HAin +DVi- Vi+
-
+HAin +
INPUT 218Vdc
DVi- Vi+
INPUT 3
-
+HAin + D VpoMpo
-
+HAo+
OUTPUT
FA-Plus/C or FA-Plus
SEC
PRI
230
Main
110 0
--
++
SU3-PLUS
Take off JP1 jumper
of all the distributors
except in the last one.
A
_
+D
Malla
Vin Vout
CN4
A
_
+D
Malla
Vin Vout
CN4
ED 1 D2
+
D4L-PLUS
JP1
S
Next distributor
( )
*
FA-Plus/C
rev.938072
SEC
PRI
230110 0
--
++
AP
( )
*
To access door panel S
Access door panel
Main
Lock release
Vd.c.
M
(1)
(1)
SW2
S
DMalla
Vin-AinAout Vin+ Vout-Vout+
CN2
+
-
+CV1CV2
-
10
1
9
2
8
3
7
4
6
5
CN5
SW1
DVi- Vi+
-
+
-
+HAin +DVi- Vi+
-
+HAin +
18Vdc
DVi- Vi+
-
+HAin + D VpoMpo
-
+HAo+
FA-Plus/C
rev.938072
SEC
PRI
230110 0
--
++
SU3-PLUS
S
S
18
INSTALLATION DIAGRAMS
The installation diagram shows the connection of a video system with up to 5 door panels for the same
building. Master door panel with "AP" function, (external push button to exit from the building).
If the system has more than two switch units, wire them as the second is connected; connecting the
output of the previous switch unit to the input of the next switch unit. In the last unit will connect the
monitor Bus.
Important:Will be necessary to connect a power supply on the door panels with "AP" function
and/or EL502 dc/ac converter module to connect a.c lock release (only Stadio door panel).
Do not connect the positive terminal of the door panel (with power supply) to the switch unit.
Remember: tors ephones porter's exchanges and digital repeater will beDistribu , monitors, tel ,
connected to the output of the switch unit, never between door panel and switch unit.
( )
*
Video installation without coaxial cable and 2 switch units.
To access door panel
To access door panel
Lock release
Vd.c.
Main
Access door panel
IMPORTANT:For the configuration and programming of each equipment, see the corresponding manual.
M =Master.
S =Slave.
INPUT 1 INPUT 2
INPUT 3 OUTPUT
SW2
DMalla
Vin-AinAout Vin+ Vout-Vout+
CN2
+
-
+CV1CV2
-
10
1
9
2
8
3
7
4
6
5
CN5
SW1
DVi- Vi+
-
+
-
+HAin +DVi- Vi+
-
+HAin +
18Vdc
DVi- Vi+
-
+HAin + D VpoMpo
-
+HAo+
SEC
PRI
230110 0
--
++
SU3-PLUS
( )
*
FA-Plus/C
rev.938072
SEC
PRI
230110 0
--
++
AP
( )
*
JP1
A
A
D
D
CT +
+
Vpi
Vd1
Mpi
Md1
_
_
A
D
CT
+
Vd6
Md6
_
A D+ Vpo Mpo
_
D6L-Plus/2H
VpMp
AD
_
+
EL562
JP1
VpMp
AD
_
+
EL562
JP1
19
FA-Plus/C or FA-Plus
Main
Take off JP1 jumper
of all the distributors
except in the last one.
Next distributor
To access door panel S
Access door panel
Main
Lock release
Vd.c.
M
(1)
(1)
INPUT 1 INPUT 2
INPUT 3 OUTPUT
1095 Budapest, Mester utca 34.
Tel.: *218-5542, 215-9771, 215-7550,
216-7017, 216-7018 Fax: 218-5542
Mobil: 30 940-1970, 30 959-0930
E-mail: [email protected] Web: www.delton.hu
www.golmar.hu
1141 Budapest, Fogarasi út 77.
Tel.: *220-7940, 220-7814, 220-7959,
220-8881, 364-3428 Fax: 220-7940
Mobil: 30 531-5454, 30 939-9989
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Golmar TRIP TSU3-PLUS ML REV.0116 Owner's manual

Category
Video switches
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI