Classic Exhibits VK-1230 Setup Instructions

Type
Setup Instructions
© 2022
Order #XXXXX
Locked layer contains
placeholder marks.
Plan View 10’
10’
VK-1230 - 10’ x 10’ Display
If you would like to tell us about your experience with your setup instructions please email us at [email protected]
SETUP INSTRUCTIONS
REV 12/2022
© 2022
Order #XXXXX
Locked layer contains
placeholder marks.
= 1 sq foot
Plan View
© 2022
Order #XXXXX
DO NOT USE POWER TOOLS
ALL CONNECTIONS MUST
BE TIGHTLY SECURED
Part Identification - Numbering
Spline Connection Base Plate & Extrusion Connection
General Setup Instructions
- Read entire setup instruction manual prior to
unpacking parts and pieces.
- The setup instructions are created specifically
for this configuration.
- Setup instructions are laid out sequentially in
steps, including exploded views with detailed
explanation for assembly.
WARNING
Cleaning & Packing
- For Cleaning Metal, Plex, & Laminate Parts:
Use a MILD NON-ABRASIVE cleanser and
soft cloth/paper towel to clean all surfaces.
- Keep exhibit components away from heat
and prolonged sun exposure.
Heat and UV exposure will warp and
fade components.
- Retain all provided Packing Materials.
All provided packing materials are for
ease of repacking & component protection.
Disassembly
- For loss prevention, tighten all set screws
and locks during disassembly.
7A
Hex Tool - Essential for Assembly
Extrusion & Lock Connection Engaged Lock
LADDERS OR LIFTS
MAY BE REQUIRED
General Information
© 2022
Order #XXXXX
Locked layer contains
placeholder marks.
1) Mounting plate & wing nuts,
in packed position.
6) Place fixed counter bolts
into mounting plate, then
secure using wing nuts.
Completed Assembly
Counter Attachment
Wing Nut
Fixed
Bolts
Mounting
Plate [11A]
10
11
Counter
Attach mounting plate to curved extrusion
[10], using bolt. Insert fixed bolts, located
on underside of counter, into holes of flange
plate. Secure with wing nuts.
Mounting Plate
w/ Wing Nuts
Bottom view
of counter
10
11
Wing Nut
Wing Nut
Counter
2) Mounting plate bolt in,
packed position.
10
11
Bolt
5) Tighten bolt, using hex tool,
to secure.
Mounting Plate
Bolt
3) Place mounting plate onto
[10] then tighten bolt, part
way, allowing some rotation
for final positioning.
4) Place fixed counter bolts
into mounting plate, then lift
counter to re-tighten bolt.
Mounting Plate
10
Fixed
Counter
Bolt
Fixed
Counter
Bolt
Hex Tool
Keep mounting plate [11A] and wing nuts
attached to counter, when packing.
Keep bolt attached to [10], when packing.
Bolt
Mounting
Plate
Bottom view of counter Bottom view of counter
Counter Assembly
© 2022
Case 1 of 2
Order #XXXXX
Locked layer contains
placeholder marks.
Top View of Each Level
Level 3 Level 4Level 1 (Bottom Level)
Wing Panels
Round
Sign
Assembled
Header
Base
Plates
10A 11
10
11A
Counter
Top
Graphics
Canopy Pieces
LightLight
Shelf
Setup
Hardware
Monitor
Mount
A,A
B,B
3A,3B
2B,2A
4A, 4B, 5A, 5B
Level 2
Case Packing
© 2022
Case 2 of 2
Order #XXXXX
Locked layer contains
placeholder marks.
Top View of Each Level
Level 2 Level 3 Level 4 Level 5
Counter Top (2) Side Panels Front Panel
Shelf
Floor
Shelf Supports
Back Panel w/ Door
Level 1 (Bottom Level)
Case Packing
© 2022
Step 1 of 4
Order #XXXXX
Locked layer contains
placeholder marks.
When Assembled
Steps:
1) Attach base plates [1] lower verticals [2A] and [3A], using bolts.
2) Connect verticals [2A to 2B] and [3A to 3B], using connection bars [B].
See Straight Connection with Knobs detail.
3) Connect horizontals [4A to 4B] and [5A to 5B], using connection bars [A].
See Straight Connection with Knobs detail.
4) Connect assemblies [2A/2B] and [3A/3B] with assemblies [4A/4B] and [5A/5B].
See Corner Connection with Knob detail.
5) Attach graphic to Velcro on back of assembled Backwall.
Item
1
2A,2B
3A,3B
4A,4B
5A,5B
Description
Base Plate
42” S40 Vertical Extrusion w/ A10 Clamps
42” S40 Vertical Extrusion w/ A10 Clamps
45” Z45 Horizontal Extrusion
45” Z45 Horizontal Extrusion
Qty.
2
1,1
1,1
1,1
1,1
Canopy
Mount
Connector
Set Screw
S40
Attach connector to top of vertical
extrusion then tighten set screws
to secure.
Insert canopy mount into threaded
hole in top of connector then turn
canopy mount clockwise to tighten
in place.
Canopy Mount Attachment
Turn to
tighten
Connection bars [B]
stay attached to [2A,3A].
Slide connection bar between
extrusions, then turn knobs
clockwise to tighten lock.
Straight Connection
with Knobs
Do not over tighten Knobs
Knob
Knob
Corner Connection
with Knob
Turn knob clockwise
to tighten lock.
Do not over tighten Knobs
Knob Keep Canopy Mounts
attached to [2B,3B].
Keep A10 clamps
attached to [2A,2B,3A,3B].
Canopy
Mount
Canopy
Mount
Connection Bar
1
Bolt
Bolt
1
3B
2B
B
B
4B
4A
5B
5A A
A
Velcro on extrusions
must face to BACK of
assembled Backwall.
2A
3A
Velcro on
BACK/Bottom Edges
of Top Horizontals
Velcro on BACK/Top
Edges of Bottom
Horizontals
Velcro on BACK/Inside
Edges of Right Verticals
Velcro on BACK/Inside
Edges of Left Verticals
Horizontal Placement
Stopper
Set upper horizontal extrusion
on top of stopper of verticals.
FRONT VIEW
Connection bars [A]
stay attached to [4A,5A].
Backwall Assembly
© 2022
Step 2 of 4
Order #XXXXX
Locked layer contains
placeholder marks.
Wing
Wing
3B
3A
2B
2A
Clamp
Wing
Wing
Knob
Set Screw
Connector
1) Slide connector of clamp
into extrusion groove.
2) Tighten set screw when
A10 is in desired location.
3) Insert wing into clamp.
4) Tighten knob on clamp
to secure wing in place.
Clamp Attachment
A10 Clamp
Keep A10 clamps
attached to verticals.
Keep curved extrusion [10]
& horizontal [11] assembled.
FRONT VIEW
Monitor Mount Attachment
Connectors
V4
Connectors
*
Slide V4 Connectors into groove
of Extrusion. Tighten Set Screws
to secure connectors in place.
Attach Monitor Mount back
piece to Extrusion, using bolts.
Then slide monitor mount into
back piece.
Bolts
Monitor
Mount
Back
Piece
Steps:
1) Connect lights to top horizontal extrusions [5A/5B]. See Light Connection detail.
2) Attach extrusions [10/11] and shelf to vertical [2A].
3) Attach support leg [10A] to curved extrusion [10].
4) Attach flange plate [11A] to top of curved extrusion [10], using bolt.
5) Attach counter top to counter mounting plate [11A]. See Counter Assembly page.
6) Attach Wings to A10 clamps. See Clamp Attachment detail.
7) Attach Monitor Mount to vertical [2B]. See Monitor Mount Attachment detail.
8) Attach Sign to vertical extrusion [3B]. See Sign Attachment detail.
Item
10
10A
11
11A
Qty.
1
1
1
1
Description
30.2” Curved Extrusion
Support Leg
12.184” Horizontal Extrusion
Counter Mounting Plate
*
*
Graphic
11A
10
10A
Screw
Shelf
11
*
*
*
*
Connector
Sign Attachment
Cap
Sign
Standoff
Slide connector into groove of extrusion.
Tighten set screws to secure in place.
Screw standoff into connector. Place
sign between standoff and cap then
tighten cap to secure sign.
*
Slide light onto clip then lock clip
into groove of horizontal extrusion.
Clip
Light
Light Connection
Clip
Light
Horizontal Extrusion
When assembled
Backwall Attachments
© 2022
Step 3 of 4
Order #XXXXX
Using Your Setup Instructions
The Aero Setup Instructions are created specifically for your configuration. The instructions include an
exploded view of the frame which is sequentially labeled. We encourage you to review the instructions
before attempting to assemble your exhibit.
Connections are kept very simple; no tools required. Everything assembles with push-button connectors.
Cleaning and Packing Your Display
1) Use care when cleaning aluminum extrusion or acrylic inserts. Use only non-abrasive cleaners.
2) Retain all packing material. It will make re-packing much easier and will reduce the likelihood
of shipping damage.
Push-Button
Push-Button
66
6
6
Numbered Label
Connections are made by holding the button down and
sliding the red tube into opposing tube until button locks
into the hole of the opposing tube. To disassemble, push button
and pull or twist extrusions apart.
Locked layer contains
placeholder marks.
Steps:
1) Connect canopy pieces together as shown.
2) Apply pillow case graphic to assembled canopy
AA
BB
DD
CC
Push-Button
Push button then rotate
for packing purposes
Canopy Assembly
© 2022
Step 4 of 4
Order #XXXXX
Locked layer contains
placeholder marks.
*
Completed Pedestal Assembly
Pedestal Base Assembly
Pedestal Top Attachment
Pedestal Top
Screw
Cap
Back Panel
with Door
Side Panel
Side Panel Front Panel
Floor
Shelf Support
Shelf
Align hole with pin Rotate pin. Spring
will push pin into hole.
Pedestal Top Attachment
12
*
Pin
*
Remove pins for floor from
side panels when packing.
Setup Instructions:
1) Attach pins at bottom interior of side panels. Note: Pins are designed to be slightly angled.
2) Use screw caps to secure the side panels to front panel and back panels, making sure Velcro is facing inward.
3) Slide floor into the bottom of assembled pedestal base. The floor will sit on pins of the side panels.
4) Connect shelf supports to Velcro on panels, then place shelf on top of supports.
5) Attach pedestal top to assembled pedestal base. See Pedestal Top Attachment detail.
LTK-1001 Counter Assembly
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

Classic Exhibits VK-1230 Setup Instructions