Omron E5 R Quick start guide

  • Hello! I've reviewed the datasheet for the OMRON E5AR and E5ER Digital Controllers. This document outlines a advanced Digital Controller featuring rapid response and high resolution, with capabilities like sampling at 50 ms and measuring with 0.01°C resolution. These controllers are designed for applications needing precise and quick control. I'm here to answer any questions you might have about the device and its various functions.
  • What is the sampling rate of E5 series controllers?
    What is the resolution of measurements?
    What communication protocol does the controller support?
    What types of control does this controller support?
    What type of display does the controller has?
S
p
ecification
s
Displa
y
Supply volta
ge
In
p
ut resolutio
n
Samplin
g
perio
d
Fun
c
ti
o
n
s
7-se
g
ment LCD with backli
g
h
t
Refer to the E5 R datasheet (H122) for more information.
Display colors: Red,
reen, and oran
Number of di
g
its per display line:
5
Number of displa
y
lines:
3
100 to 240 VAC
,
24 VAC/VD
C
50 ms
p
er loo
p
Control t
y
p
e
Co
ntr
o
l m
e
th
od
Tunin
g
Settin
g
relate
d
C
ontrol relate
d
Communication
s
Standard, heatin
g
/coolin
g
, position proportional
ON/OFF
,
2-PI
D
Autotunin
g
SV limits,
p
arameter
p
rotection, 8 bank
s
MV rate-of-chan
g
e limit, MV when stopped, MV for error, SV trackin
g
, special control (cascade, proportional
)
RS-485 (CompoWa
y
/F or MODBUS
)
°
±
°
±
1 di
g
it max
.
±
:
:
:
:
:
:
:
Digital Controller for Control Applications
Requiring Rapid Response and High Resolution.
The E5 R samples at 50 ms per loop for use with high-speed
response equipment, such as ceramic heaters. Measurements,
fluctuation detection, and logging for environmental testing equipment
are performed at a high resolution of 0.01°C.
The R in E5 R represents the two areas where this Digital Controller
excels - Rapid response and high Resolution.
A
dvanced & So
ph
isticated Digital Controlle
r
E
5
A
R
96
x
96
x
9
5m
m
(
W x H x D
)
E
5
E
R
4
8
x
96
x
9
5m
m
(
W x H x D
)
C
at. No. H121-E1-
01
Auth
o
riz
e
d Di
s
tribut
o
r
:
Note: Specifications subject to chan
g
e without notice
.
OMRON Cor
p
oratio
n
Industrial Automation Compan
y
Measurin
g
and Control Divisio
n
Shiokoji Horikawa, Shimo
g
yo-ku
,
K
y
oto, 600-8530 Japa
n
Tel:
(
81
)
75-344-7080/Fax:
(
81
)
75-344-718
9
Re
g
ional Headquarter
s
O
MR
O
N EUR
O
PE B.V
.
We
g
alaan 67-69, NL-2132 JD Hoofddor
p
The Netherland
s
Tel:
(
31
)
2356-81-300/Fax:
(
31
)
2356-81-38
8
O
MR
O
N ELE
C
TR
O
NI
C
S LL
C
1 East Commerce Drive, Schaumbur
g
, IL 6017
3
U.
S
.A
.
Tel:
(
1
)
847-843-7900/Fax:
(
1
)
847-843-856
8
O
MR
O
N ASIA PA
C
IFI
C
PTE. LTD
.
83 Clemenceau Avenue
,
#11-01, UE Square
,
239920 Sin
g
apor
e
Tel:
(
65
)
6835-3011/Fax:
(
65
)
6835-2711
OMRON CHINA CO.
,
LTD. BEIJING OFFIC
E
Room 1028, Office Buildin
g
,
Beijin
g
Capital Times Square,
No. 88 West Chan
g
'an Road,
Beijin
g
, 100031 Chin
a
Tel:
(
86
)
10-8391-3005/Fax:
(
86
)
10-8391-368
8
P
rinted in Ja
p
an
0
403-1.5M
(
0403
)
(
O
)
Advanced Di
g
ital Controlle
r
Rapid Response & Hi
g
h Resolution
E5 R Digital Controllers
Ba
s
i
c
m
o
d
e
l
s
1 loo
p
for standard
control/1 loo
p
for
heatin
g
and coolin
g
c
o
ntr
ol
2 loo
p
s for standard
control/2 loo
p
s for
heatin
g
and coolin
g
c
o
ntr
ol
1 loo
p
for cascade
c
o
ntr
ol
1 loo
p
for standard
control with remote
SP
1 loo
p
for
p
ro
p
ortional
c
o
ntr
ol
1 loo
p
for
p
osition
-
p
ro
p
ortional control
4 alarm out
p
uts, 2 event in
p
uts, 2
out
p
uts (control/transfer
)
4 alarm out
p
uts, 6 event in
p
uts,
RS-485 communications
,
4 ou
t
-
p
uts (control/transfer
)
Ba
s
i
c
m
o
d
e
l
s
1 loo
p
for standard
control/1 loo
p
for
heatin
g
and coolin
g
c
o
ntr
ol
4 alarm out
p
uts, 2 event in
p
uts, 2 ou
t
-
p
uts (control/transfer)
4 alarm out
p
uts, 2 event in
p
uts,
RS-485 communications
,
4 ou
t
-
p
uts (control/transfer
)
4 alarm ou
p
uts, 4 event in
p
uts,
2 rela
y
ouputs (open, closed
)
4 alarm out
p
uts, 4 event in
p
uts,
2 rela
y
outputs (open, closed
)
RS-485 communications
,
1 ou
t
-
p
ut (transfer
)
4 alarm out
p
uts, 4 event in
p
uts,
RS-485 communications
,
4 ou
t
-
p
uts (control/transfer
)
2
-loo
p
m
o
d
e
l
s
2 loo
p
s for standard
control/1 loo
p
for
heatin
g
and coolin
g
c
o
ntr
ol
1 loo
p
for cascade
c
o
ntr
ol
1 loo
p
for standard
control with remote
S
P
1 loo
p
for
p
ro
p
ortional
c
o
ntr
ol
4 alarm out
p
uts, 4 event in
p
uts,
RS-485 communications
,
2 ou
t
-
p
uts (control/transfer
)
2-loo
p
m
o
d
e
l
s
4 loo
p
s for standard
c
o
ntr
ol
2 loo
p
s for standard
c
o
ntr
ol
2 loops for heatin
g
and
coolin
g
contro
l
4 alarm out
p
uts, 4 event in
p
uts,
RS-485 communications
,
4 ou
t
-
p
uts (control/transfer
)
4-loo
p
m
o
d
e
l
s
P
osition-
p
ro
p
ortiona
l
co
ntr
o
l m
o
d
e
l
s
1 loo
p
for
p
osition
-
p
ro
p
ortional control
4 alarm out
p
uts, 4 event in
p
uts,
2
rela
y
outputs (open, closed
)
4 alarm out
p
uts, no event in
p
ut,
2
rela
y
outputs (open, closed
)
RS-485 communications
,
1 ou
t
-
p
ut (transfer
)
P
osition-
p
ro
p
ortiona
l
co
ntr
o
l m
o
d
e
l
s
E
5
A
R
Hi
g
h-speed Samplin
g
at 50 m
s
Resolution of 0.01°C with
P
latinum R
es
i
s
tan
ce
Th
e
rm
o
m
e
t
e
r
s
Stable control in hi
g
h-speed response applications.
SV
Hi
g
h-speed
samplin
g
5
0
m
s
Tim
e
Hi
g
h-speed response:
Onl
y
a few seconds are required to reach the set value
.
s
fer out
p
u
t
Analo
g
inpu
t
Hi
g
h
re
s
olutio
0
.
01
°
C
a
n
s
fer/control
u
tpu
t
d
er
)
g
h
s
olution:
4
3
,
00
0
.
01
°
C
4 Loops in a Sin
g
le Controlle
r
A Variet
y
of I/O to Control with PLC
s
PV1
PV1
MV1
MV2
M
V
2
M
V
3
MV4
PV2
PV2
PV
3
PV4
MV
PV
PID
PID
PID
PID
PID
PID
PID
Control 4 Loops with a Sin
g
le Controlle
r
Cascade Control with a Sin
g
le Controller
Proportional Control with a Sin
g
le Controlle
r
E5AR onl
y
MV1=RSP
SP
E
5
A
R
E
5
E
R
E
5
A
R
E
5
E
R
P
roportional settin
g
Sim
R
SP
PV
R
S
-485
(CompoWa
y
/F
)
P
V and
S
V data
can
b
e shared easil
y.
CS/CJ Series
,
CQM1
,
or CPM2
A
Event inputs
M
ultipoint analo
g
input
s
(4 in
p
uts: IN1 to IN4
)
e
r
ts
Multipoint analo
g
output
s
(4 out
p
uts: OUT1 to OUT 4
)
Auxiliar
y
output (alarms, etc.
)
Ra
p
id
Res
p
onse
H
i
g
h
R
eso
luti
on
M
u
lti
-
loo
p
A
pp
lication
s
Bondin
g
equipmen
t
Eva
p
oration equi
p
men
t
Coil windin
g
equipmen
t
A
pp
lication
s
Sterilization equi
p
men
t
Food processin
g
equipmen
t
A
pp
lication
s
manufacturin
g
equipment
(exposure and air conditionin
g)
testin
g
equipmen
t
Food processin
g
equipmen
t
P
r
o
bl
e
m
So
luti
on
P
r
o
bl
e
m
So
luti
on
P
r
o
bl
e
m
So
luti
on
LCD with 3 Lines of 5 Di
g
it
s
Easy Setting with
Thermo Tools Su
pp
ort Softwar
e
P
arameter
s
Easy Initial
Setup
/