4.List of functions (Refer to P 39 and after of operation manual)
There are two kinds of functions, J group that mainly sets functions and H group that mainly sets the data. Please
set functions of J04 to J07 in the list according to the driving mode (Refer to P.4 of this manual) without fail.
Also, depending on functions, adjustable data may be restricted by other functions. Please refer to the operation
manual for the details.
<List of J group functions>
*Underlined figures are initial values for ECG25/ECJ45. But own initial value only for ECJ45 exists partly. The initial
values are shown with broken line.
*6 of J06 and J11 are installed only for ECJ45.
J№ Name & Set range
(Initial value is underlined)
Change
during
driving
Record
of set
value
J00 Operation lock
0: Operation lock OFF
1: Operation lock ON
Can
not
J01
Setting of current rating
For ECG25
0.10~2.50(A)
Use range: 0.20~2.00(A)
Initial value: 2.00
For ECJ45
0.10~5.00(A)
Use range:0.50~4.50(A)
Initial value: 4.00 *
Can
not
J02
Selection of driving method
0: External control + Sensor
1:Reverse of external control +
Sensor
2: Panel control
3: Panel control + Sensor
Can
J03 Selection of JOG driving method
0: Do not make JOG operation
1: Accept JOG operation Can
J04
Setting of F-V curve
F:N25 and others (Full wave system)
H:N40 and others (Half wave system)*
C:HF10 and others (High frequency system)
0~17 (Others)
Can
not
J05
Selection of feedback mode
0: Constant voltage mode
1: Constant amplitude mode
2: Resonance point tracking +
Constant amplitude mode
3:Calibration for constant amplitude
mode
4: Calibration for resonance point
tracking
Can
not
J06
Setting of driving condition
0: Manual setting
1:Light weight high speed driving
2:Light weight medium speed driving
3:Heavy weight medium speed driving
4:Light weight low speed driving
5:Heavy weight low speed driving (For S30)
6:For G50*
Can
not
J№ Name & Set range
(Initial value is underlined)
Change
during
driving
Record
of set
value
J07 Polarity of vibration sensor
0: Do not reverse polarity
180: Reverse polarity
Can
not
J08
Selection of function of AL1 terminal
0:Outputting work shortage signal
1:Outputting overload signal
2:Outputting of OR for work shortage
signal and overload signal
3: Outputting when LIMIT lamp lights
4:Outputting of OR signal when
LIMIT lamp lights and for overload
warning
5:Outputting of OR signal when
LIMIT lamp lights and for work
shortage and overload warning
6:Outputting of driving signal on
AL1 terminal
Can
J09
Display of error history
Displaying latest error data
(Content of protection function
behaviors) up to three
―
J10
Setting of initial value
(All clear of memory)
0:Normal operation mode
1:Rewriting the memory into the
initial value
Can
not
J11*
Change of carrier frequency*
0:20kHz
1:14kHz
2:10kHz
Can
not
J12
Selection of functions of EM terminal
0:Contact point is “Close” at the
time of problem
1:Contact point is “Open” at the
time of problem
2:Selection is not possible
3:Selection is not possible
4:Contact point is “Close” during driving
5:Contact point is “Close” when driving
preparation is completed
Can
not