  • Hello! I am an AI chatbot trained to assist you with the Tennant M-5680,M-5700,M-T16,7200,7200SS,T15 Instruction Bulletin. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
ServiceLINK® QuiQ™ Charger Reprogramming Instructions (1-12) 1
ServiceLINK® QuiQ™ Charger
Reprogramming Instructions
IB-9009513
Home
2 ServiceLINK® QuiQ™ Charger Reprogramming Instructions (1-12)
Disconnect QuiQ charger from AC power supply and from batteries.
1.
Connect QuiQ USB interface module to battery charger and Service-
LINK USB port as shown below. NOTE: Be sure to use the USB port
identied below. The other USB ports are disabled.
2.
Disconnect
Disconnect
QuiQ USB
Interface Module
+!- !
ServiceLINK® QuiQ™ Charger Reprogramming Instructions (1-12) 3
Launch the QuiQ Programmer software from the start menu.
4.
Reconnect AC power supply.
3.
Reconnect
4 ServiceLINK® QuiQ™ Charger Reprogramming Instructions (1-12)
Click on OK to conrm charger connectivity.
5.
Select and delete the unused algorithm Algld8-v0.01” from the Al-
gorithms Present” eld (see below). The charger holds a maximum
of 10 algorithms, so one must be deleted to add a new program.
NOTE: Certain battery chargers may not have Algld8-v0.01. Delete
existing algorithm Algld26-v... instead.
6.
ServiceLINK® QuiQ™ Charger Reprogramming Instructions (1-12) 5
Select and add to charger the new algorithm Algld28-v1_00.enc
from the “Battery Charge Algorithms eld (see below).
Select and set as default the new algorithm Algld28-v1_00.enc
from the Algorithms Present eld (see below).
7.
8.
6 ServiceLINK® QuiQ™ Charger Reprogramming Instructions (1-12)
Verify the new algorithm #28 in the “Status” eld.
Done. Disconnect QuiQ USB interface cable from ServiceLINK de-
vice and from QuiQ battery charger.
9.
10.
/