Tennant 614002,M-T7,M-3640,M-1610,5010,T3 Instruction Bulletin

Type
Instruction Bulletin

This manual is also suitable for

Tennant 614002,M-T7,M-3640,M-1610,5010,T3 offers a comprehensive cleaning solution for various surfaces. Its versatility extends to hard floors, carpets, and even stairs, making it an ideal choice for both residential and commercial cleaning needs. With its ability to switch between scrubbing and drying modes, it ensures efficient cleaning and quick drying times, leaving your floors spotless and safe to walk on.

Tennant 614002,M-T7,M-3640,M-1610,5010,T3 offers a comprehensive cleaning solution for various surfaces. Its versatility extends to hard floors, carpets, and even stairs, making it an ideal choice for both residential and commercial cleaning needs. With its ability to switch between scrubbing and drying modes, it ensures efficient cleaning and quick drying times, leaving your floors spotless and safe to walk on.

SAVE THESE INSTRUCTIONS
QuiQ 24V Off--Board Battery Charger
Page1of2
IB 1034017 Rev.01 (05--12)
FOR SAFETY: Before operating battery charger, read the manual supplied by the charger manufacturer.
Charger Programming Instructions
Estimated time to complete: 5 minutes
NOTICE: For chargers equipped with new machines, the
algorithm position is factory set to match the batteries
supplied with your machine.
For replacement chargers, the algorithm position is set at
position 2 (default).
The charger is pre--loaded with 6 algorithm positions as
shown in the chart below.
NOTE: See chart on backside for earlier models equipped
with 10 algorithm positions.
Battery Charger Algorithm Chart (6 Positions)
Algorithm
Position
of Order
Algorithm
ID Setting
No. of LED
Flashes
Battery Description
1 1 Trojan Flooded w/ temperature
sensor
23* Trojan T105 constant power dv/dt
(200--250 Ah@20hr lead/acid battery)
37* Trojan J305 constant power dv/dt
(>250Ah@20hr lead/acid battery)
41--2 Exide/Sonnenschein Gel --240
(220Ah@20hr)
52--8 MK 8GGC2 Gel (180Ah@20hr)
64--3 Discover AGM
*Common Tennant batteries.
To Check the Current Algorithm ID Setting:
1) Disconnect battery connector from battery pack.
2) Connect the AC power cord into an AC outlet. At start
up, the charger LED will display three self test
flashes, one red, one green and one amber, followed
by a series of green flashes which is the algorithm ID
setting (See Algorithm ID Settings in chart above).
The algorithm ID setting (series of green flashes) will
repeat for approximately 11 seconds then end with
red flashes (See Examples below).
3) To recheck the algorithm ID, unplug AC power cord
for 15 seconds or until LED stops flashing red then
reconnect AC power cord.
To Change the Algorithm ID Setting:
NOTE: Before changing the Algorithm ID setting, confirm
current setting as described in first column.
1) Plug the charger’s AC power cord into an AC outlet.
2) At start up, the LED will display 3 self test flashes
followed by a series of green flashes (See Examples
below). While the series of green flashes are flashing,
approx. for 11 seconds, plug the battery connector
into the battery pack for 2 seconds then unplug as
shown in the photo.
This will advance the algorithm ID setting to the next
position in the order shown in the chart.
Count 2 seconds
To continue to advance the algorithm ID to the next
position repeat the 2 second plug and unplug process
while the LED is still flashing green until desired
algorithm ID is reached. Each time you advance to a
new setting you have another 11 seconds to continue
advancing. While advancing, count the number of
green flashes each time to confirm new setting.
3) To store the new algorithm setting, plug the battery
connector back into battery pack until the charger
relay clicks (approx. 10 seconds). This step must be
done during the 11 second span when LED is flashing
green .
NOTE: If the LED is flashing red anytime during
this procedure you must start over. To start over,
disconnect AC power cord and battery connector
for 15 seconds to reset charger.
4) To confirm the new algorithm is properly set, check
the algorithm ID setting as described in the
instructions.
Contact Tennant if your battery pack is not supported
by the charge algorithms loaded in your charger.
pause
Self Test at start up Algorithm ID Setting 3
pause
Position 2 = Algorithm ID Setting 3
pause
Algorithm ID Setting 2--8
pause
Position 5 = Algorithm ID Setting 2--8
short
pause
Ends w/
repeated double
red flashes
Alg ID
flashes will
repeat for
11 seconds
Alg ID
flashes will
repeat for
11 seconds
Examples:
(3 flashes) (3 flashes)
(2 flashes followed by 8 flashes)
(2 flashes) (8 flashes)
pause
Algorithm ID Setting 3
(3 flashes)
Self Test at start up
(3 flashes)
LED
Ends w/
repeated double
red flashes
For double digit Alg ID settings
Home
Page2of2
IB 1034017 Rev.01 (05--12)
Use Chart below for earlier models equipped with 10
algorithm positions:
Battery Charger Algorithm Chart (10 Positions)
Algorithm
Position
of Order
Algorithm
ID Setting
No. of LED
Flashes
Battery Description
1 1 Trojan Flooded w/ temperature
sensor
23* Trojan T105 constant power dv/dt
(200--250 Ah@20hr lead/acid battery)
3 5 Trojan 30XHS
4 6 DEKA 8G31 GEL
57* Trojan J305 constant power dv/dt
(>250Ah@20hr lead/acid battery)
6**
8Concorde 10xAh AGM
1--2 Exide/Sonnenschein Gel --240
(220Ah@20hr)
2--6 MK 8GGC2 Gel (180Ah@20hr)
2--8 MK 8GGC2 Gel (180Ah@20hr)
71--1 Generic 224Ah flooded constant
power dv/dt (parallel enabled)
82--7 Crown CR--325
94--3 Discover AGM
10 7--3 Generic 400Ah flooded constant
power dv/dt (parallel enabled)
*Common Tennant batteries.
** Depending on how your charger is programmed, position 6 may display
algorithm ID 8, 1--2, 2--6 or 2--8.
Refer to page 1 for Charger Programming Instructions.
pause
Self Test at start up Algorithm ID Setting 3
pause
Position 2 = Algorithm ID Setting 3
pause
Algorithm ID Setting 2--8
pause
Position 6 = Algorithm ID Setting 2--8
short
pause
Ends w/
repeated double
red flashes
Alg ID
flashes will
repeat for
11 seconds
Alg ID
flashes will
repeat for
11 seconds
Examples:
(3 flashes) (3 flashes)
(2 flashes followed by 8 flashes)
(2 flashes) (8 flashes)
pause
Algorithm ID Setting 3
(3 flashes)
Self Test at start up
(3 flashes)
LED
Ends w/
repeated double
red flashes
For double digit Alg ID settings
Home
  • Page 1 1
  • Page 2 2

Tennant 614002,M-T7,M-3640,M-1610,5010,T3 Instruction Bulletin

Type
Instruction Bulletin
This manual is also suitable for

Tennant 614002,M-T7,M-3640,M-1610,5010,T3 offers a comprehensive cleaning solution for various surfaces. Its versatility extends to hard floors, carpets, and even stairs, making it an ideal choice for both residential and commercial cleaning needs. With its ability to switch between scrubbing and drying modes, it ensures efficient cleaning and quick drying times, leaving your floors spotless and safe to walk on.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI