1. Introduction
Congratulations on choosing a Dedicated Micros Series 508 Camera Housing. This operation
manual provides information on the mounting variations, and access to the Series 508 Camera
Housings.
This operation manual will provide all the necessary information to install the Series 508 Camera
Housing.
2. Index
1. Introduction 1
2. Index 1
3. Unpacking 2
4. List of contents 3
5. Component Spares 3
6. Circuit Diagram 4
7. Operation 5
8. Mounting Instructions 6
9. Outline Dimensions 7
10. Specifications 8
11. Customer Electrical Connections 8
Type 508 Installation Manual Page. 1
508_complete1.qxd 29/3/05 3:12 pm Page 1
3. Unpacking
Method
The type 508 housing comes packed in the orientation shown in (fig.1)
To bring the 508 into operational service follow the following procedure.
1. Using the spanner (supplied) loosen the locking nut.
2. Rotate the extruded bracket arm and cast base through 180°
3. Retighten the locking nut, ensuring the extruded bracket arm is in the desired position. (fig2)
The 508 housing is now ready to mount. (Refer to mounting Instructions Section)
Type 508 Installation Manual Page. 2
Locking nut
Locking nut
Rotate 180°
Fig.1
Fig.2
508_complete1.qxd 29/3/05 3:12 pm Page 2
4. List of contents
Before installation please remove the components from the packaging and check that all items
listed below have been supplied.
5. Component Spares
Type 508 Installation Manual Page. 3
A. 1 x Type 508 housing
B. 1 x Type 508 Handbook
C. 1 x 3mm A/F Allen Key
D. 1 x 4mm A/F Allen Key
E. 1 x 5mm A/F Allen Key
F. 1 x Spanner
G. 1 x Insulating Pad
H. 1 x Screw Insulator
I. 1 x 1/4” UNC x 3/8” Hex Hd. screw
J. 1 x M6 Plain Washer
K. 1 x M20 Cable Gland
Description
Heater - 240V
Heater - 110V
Heater - 24V
Heater - 12V
Thermostat
Window
Front Gasket
Rear Gasket
Fuse 1 Amp
Sealing Plug
Cable Gland
Gland Nut
Gland Washer
Ref.No.
C590
C622
C623
C624
H12a
H146
A84
A85
C15
Z20
H66
H67
H66a
Quantity
1
1
1
1
1
1
1
1
1
3
1
1
1
508_complete1.qxd 29/3/05 3:12 pm Page 3
6. Circuit Diagram
Unit fitted with a 20 x 5mm 1 Amp fuse as standard.
It is the customers responsibility to change the fuse to suit their own application.
Type 508 Installation Manual Page. 4
Cover
Earth
TB1
PLATFORM
FTB
FS1
L
E
N
Chassis
Earth
PCB1
PTC
Spare
508_complete1.qxd 29/3/05 3:12 pm Page 4
7. Operation
To gain access to the 508 housing the following procedure should be followed.
1. Remove the 6 off M5 x 20 soc. hd. screws from the back plate, using the 4mm A/F long series
ball allen key, these screws are held captive for convenience.
2. Slide the body & sunsheild along the camera platform until it becomes engaged on the hook.
3. Let the body & sunsheild hang from the hook. With the body hanging from the hook any
maintenance/ inspection of the camera and wiring can be acheived in situ.
Replacing the body is the reverse procedure.
To remove the Body and sunsheild from the platform completely, unscrew the 2 off M3 nuts from
the suspension bracket whilst the body is in the hanging position.
Type 508 Installation Manual Page. 5
1.
2.
3.
Body
Suspension Bracket
Platform
Hook
Body
Suspension Bracket
Hook
Platform
View on Arrow ‘A
Platform
Hook
Camera Platform
locates in the middle
slots only
Arrow
‘A
Body
508_complete1.qxd 29/3/05 3:12 pm Page 5
8. Mounting Instructions
Remove 4 x M6 x 16 Soc. Hd. screws from rear bracket and rotate cast base until desired position
of M20 cable gland is acheived. Replace M6 screws and tighten firmly.
To convert the housing from wall mounted to ceiling mounted orientation. Remove 2 off fixings
(item1), rotate bracket arm (item2) through 180° and refit item 1. Loosen locking nut (item 3) &
position the housing to the desired orientation and re-lock.
For additional security 2 x M6 grub screws are provided. To gain access to these grub screws,
gently prise out the two plastic stop plugs. Then using the 3mm A/F ball allen key (supplied) either
one or both of the grub screws can be tightened with the housing. in the desired orientation. To
re-orientate the hsg. at any time these grub screws must be loosened first.
Type 508 Installation Manual Page. 6
1.(2 x M6 x40 Soc. Cap hd screws)
4 x M6 x 16 Soc. Hd. Screws
Arrow ‘A
View on arrow ‘A
M20 Cable Gland
Wall
mounted configuration
3.
Ceiling
mounted configuration
2 x M6 Grub
Screws
Housing
body &
sunsheild
180°
508_complete1.qxd 29/3/05 3:12 pm Page 6
9. Outline Dimensions
Type 508 Installation Manual Page. 7
260 useable internal length
551
Poly-
carbonate
Window
10mm
Thick
Hidden Cable Bracket (Wall Mounted
Orientation) (-90° tilt down) (+/-90° Pan)
Customer
Cable Run
Locking
Nuts
91
175
Fused Mains Terminal Block
and 6 way terminal block
Hidden Cable Bracket (Ceiling Mounted Orientation)
(-90° tilt down) (+/-90° Pan)
222
146
84 Max
+/-90° Pan
A
4 off mounting
holes Ø7.5
equi-spaced
on a 101.6
508 Housing Outline
508 Camera Platform Outline
One 3 Way Fused T.B.
One 6 Way T.B.
1 Slot Ø8.0
91
182
260 Useable Internal Length
332
PTC Heater
508_complete1.qxd 29/3/05 3:12 pm Page 7
Type 508 Installation Manual Page. 8
10. Specifications
Weight
4.0kg Heater Voltage 240V
Pan Movement
+/- 90° 24V
Tilt Movement
- 90° 110V
Heater Power
9 Watts 12V
Weatherproofing Standard BS.EN.60529 IP66
11. Customer Electrical Connections
Components
1. Platform
2. Gasket
3. Housing Back
4. Plate
5. 423 Bracket Assembly
6. Cable Run
7. Locking Nut
8. Rubber Diaphragm
Ref Function
L Line
E Earth
N Neutral
1 Spare
2 Spare
3 Spare
4 Spare
5 Spare
6 Spare
Housing Wiring Layout
Arrow ‘B’
6.
7.
9.
8.
1.
10.
2.
3.
L
E
N
1 to 6
From heater
4.
5.
View on Rear T.B.’s
Arrow ‘B’
508_complete1.qxd 29/3/05 3:12 pm Page 8
Issue 1
74 0309
www.dedicatedmicros.com
UK Technical Help
Dennard Limited
Unit 4, Park Iron Works, Kingsley, Nr Bordon,
Hampshire GU35 9LY
Tel: +44 (0)1420 485713 Fax: +44 (0)1420 485714
e-mail: sales@dennard-cctv.com
European Technical Help
Dedicated Micros Europa
Neckarstraße 15, 41836 Hückelhoven, Deutschland
Tel.: +49 (0) 24 33 52 58 26 Fax: +49 (0) 24 33 52 58 20.
Dedicated Micros France
9-13 rue du Moulinet, 75013 Paris, France
Tél. : +33 1 45 81 99 99, Fax : +33 1 45 81 99 89.
Dedicated Micros Belgique
Joseph Chantraineplantsoen 1, 3070 Kortenberg, Belgique
Tél. : +32 2751 3480, Fax : +32 2751 3481
Dedicated Micros Ltd. Slovenija
Delavska cesta 26, 4208 Sencur-Slovenija
Tel: +386 (4) 279 18 90, Fax: +386 (4) 279 18 91
508_complete.qxd 29/3/05 3:27 pm Page 42
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Dedicated Micros 508 Camera Housing Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI